Proportional pressure valves type RZGO-AES
6Pages

{{requestButtons}}

Catalog excerpts

Proportional pressure valves type RZGO-AES - 1

Proportional reducing valves type RZGO-AES, 3-way direct operated, without integral pressure transducer, ISO 4401 size 06 RZGO are 3-way proportional pressure reducing valves, direct operated without integral pressure transducer, which provide pressure regulation proportional to electronic reference signal. They operate in association with electronic drivers, see table ‫ ݘ‬which supply the proportional valve with proper current to align valve regulation to the reference signal supplied to the electronic driver. They are available in different executions: • -A, without integral pressure transducer. • -AE, -AES, as -A plus analogue (AE) or digital (AES) integral electronics ‫.ܫ‬ The reduced pressure is controlled by the spool ‫ ,ܪ‬directly operated by the solenoid ‫.ܩ‬ Valve body Proportional solenoid The integral electronics ‫ ܫ‬ensures factory presetting, fine functionality plus valve-tovalve interchangeability and simplified wiring and installation. Integral electronics Main connector -BC/-BP Communication connector The electronic main connector ‫ ܬ‬is fully interchangeable for -AE and -AES executions. Standard 7 pin connector is used for power supply, analog input reference and monitor signals. 12 pin connector is used for option /Z (AES). -PS Communication connector (1) -EH Communication connector (input) -EH Communication connector (output) Screw for air bleeding MODEL CODE * Seals material: omit for NBR (mineral oil & water glycol) PE = FPM Proportional pressure reducing valve size 06 A = without integral transducer AE = as A plus integral electronics AES = as A plus integral digital electronics The valves with -BC and -BP interfaces can be integrated into a fieldbus communication network and thus digitally operated by the machine control unit. Series number Communication interfaces (only for AES) PS BC BP EH = Serial (1) = CANopen = PROFIBUS DP = EtherCAT Following communication interfaces ቧ, ቨ, ቩ, ቪ are available for the digital -AES execution: • -PS, Serial communication interface for configuration, monitoring and firmware updating through Atos PC software always present also for -BC, -BP and -EH options • -BC, CANopen interface • -BP, PROFIBUS-DP interface • -EH, EtherCAT interface Coil voltage (only for -A execution) see section ‫:ݛ‬ - = standard coil for 24VDC Atos drivers 6 = optional coil for 12VDC Atos drivers 18 = optional coil for low current drivers The coils are fully plastic encapsulated with insulation class H. Surface mounting: ISO 4401 size 06. Max flow: 12 l/min. Max pressure: 210 bar. Electronic options for -AE execution, see section ‫:ݝ‬ I = current reference input (4÷20 mA) Q = enable signal Configuration: 010 = regulation on port P, discharge in T Electronic options for -AES execution, see section ‫:ݟ‬ Q = enable signal Z = adds double power supply, enable and fault signals (12 pin connector) (1) Serial communication interface always present, also for -BC, -BP and -EH options ELECTRONIC DRIVERS FOR RZGO -AE Drivers model Data sheet Valve model Note: for power supply and communication connector see section

Open the catalog to page 1
Proportional pressure valves type RZGO-AES - 2

HYDRAULIC CHARACTERISTICS (based on mineral oil ISO VG 46 at 50 °C) RZGO-A Hydraulic symbols RZGO-AE RZGO-AES Valve model Max regulated pressure (Q = 1 l/min) 0,8 (or actual value in T port) Max pressure at port T Max flow Response time 0 - 100% step signal (depending on installation) Above performance data refer to valves coupled with Atos electronic drivers, see section ‫.ݘ‬ 4 MAIN CHARACTERISTICS Assembly position Subplate surface finishing Roughness index Ra 0,4 - flatness ratio 0,01/100 (ISO 1101) Ambient temperature Hydraulic oil as per DIN 51524 ... 535 for other fluids see section...

Open the catalog to page 2
Proportional pressure valves type RZGO-AES - 3

GENERAL NOTES RZGO proportional valves are CE marked according to the applicable Directives (e.g. Immunity/Emission EMC Directive and Low Voltage Directive). Installation, wirings and start-up procedures must be performed according to the general prescriptions shown in table F003 and in the installation notes supplied with relevant components. The electrical signals of the valve (e.g. monitor signals) must not be directly used to activate safety functions, like to switch-ON/OFF the machine’s safety components, as prescribed by the European standards (Safety requirements of fluid technology...

Open the catalog to page 3
Proportional pressure valves type RZGO-AES - 4

DIGITAL INTEGRAL DRIVERS -AES - OPTIONS Standard driver execution provides on the 7 pin main connector: Power supply - 24VDC must be appropriately stabilized or rectified and filtered; a 2,5 A safety fuse is required in series to each driver power supply Apply at least a 10000 μF/40 V capacitance to single phase rectifiers or a 4700 μF/40 V capacitance to three phase rectifiers. Reference input signal - analog differential input with 0÷+10 VDC nominal range (pin D, E), proportional to desired coil current (4÷20 mA with cable break detection, ± 10 mA, ± 20 mA or 0÷20 mA software selectable)...

Open the catalog to page 4
Proportional pressure valves type RZGO-AES - 5

12.2 5 PIN M12 COMMUNICATION CONNECTORS Serial (-PS) PIN SIGNAL TECHNICAL SPECIFICATION 1 NC do not connect 2 NC do not connect 3 RS_GND Signal zero data line 4 RS_RX Valves receiving data line 5 RS_TX Valves transmitting data line CANopen (-BC) SIGNAL TECHNICAL SPECIFICATION CAN_SHLD Shield NC do not connect CAN_GND Signal zero data line CAN_H Bus line (high) CAN_L Bus line (low) SIGNAL +5V LINE-A DGND LINE-B SHIELD PROFIBUS DP (-BP) TECHNICAL SPECIFICATION for termination Bus line (high) data line and termination Signal zero Bus line (low) 13 DIGITAL INTEGRAL DRIVER -AES-EH - MAIN...

Open the catalog to page 5
Proportional pressure valves type RZGO-AES - 6

INSTALLATION DIMENSIONS [mm] ISO 4401: 2005 Mounting surface: 4401-03-02-0-05 (see table P005) Fastening bolts: 4 socket head screws M5x50 class 12.9 Tightening torque = 8 Nm Seals: 4 OR 108 Ports P, A, T: Ø = 5 mm Port B: not used -PS communication interface, ZH-5P connector -BP communication interface, ZH-5P/BP connector -BC communication interface, ZH-5P connector -EH communication interface (input), ZM-4PM/EH connector -EH communication interface (output), ZM-4PM/EH connector = screw for air bleeding dotted line = 12 pin connector ZH-12P for option /Z

Open the catalog to page 6