OPTI 19” INDUSTRIAL CABINETS FOR SEVERE ENVIRONMENTS • IP 21 TO IP 55 • EMC AND HF ATTENUATION
Open the catalog to page 1EXPERIENCE designs, develops and manufactures in France, at its factories at Glos (Normandy) and Carros (Côte d'Azur), casing equipment for the electronics industry: cabinets, cases, racks, systems, fine sheet metal equipment, etc. ATOS has been advancing for more than forty years to provide an indoor or outdoor casing solution for every need of the electronics industry: standard, adapted standard, specific or produced from drawings. Resolutely focused on its customers, ATOS serves the Telecommunications, Transport (aerospace, rail, aviation, maritime, etc.), Electronics and IT...
Open the catalog to page 2KNOW-HOW AND DEVELOPMENT has added to its original sheet metal and modular mechanical activities by developing services to offer its customers A RANGE OF EXPERTISE IN LINE WITH THE ELECTRONICS MARKETS: STUDIES AND DEVELOPMENT PRE-EQUIPMENT, INTEGRATION Two Design Offices design standard, adapted or ”custom-made” products. Mechanical, electrical or thermal dimensioning Power distribution. Air cooling, water cooling systems up to 45 kW per cabinet. Solutions architecture: integration, energy, cooling, supervision. Mechanical and sheet metal design in 3D CAD. Electrical design: preparation of...
Open the catalog to page 3MODULAR MECHANICS Micanique modular iflOUSTRIt „ ElFCTBOflfflffi INDUSTRY Please contact the sales and marketing team or go to www.atos-racks.com for a catalogue
Open the catalog to page 5OPTIMAL LAMITPO
Open the catalog to page 6CABINET FOR SEVERE ENVIRONMENTS AtOS OPTIMAL Heights: Widths: Depths: Mechanical tests: Indices: Permitted load: The OPTIMAL cabinet has been designed as a rational solution for the protection of 19” equipment in severe indoor environments - damp and/or dusty premises, medium and high electromagnetic constraints, in both immunity and emission. CONSTRUCTION ■ Galvanised steel Z275 riveted and screwed structure, ■ Clipped EPDM gaskets with steel frame, with tin-plated copper-clad steel metal mesh for the EMC and HF versions, for the doors and panels, ■ Closed cell foam panel gaskets for IP55...
Open the catalog to page 8OPTIMAL Protected against bodies larger than 12 mm (finger, etc.) Protected against drops of water falling vertically • Base version that can become an EMC version without dismantling equipment. • Door end stops,gaskets on panels. Protected against bodies larger than • Possibility of moving to IP 31 by adding grids on air inlets. Protection against dust Protected against drops of water falling vertically Protected against water jets in all directions with a nozzle • Side and rear panels fixed at 500 mm intervals, • Closed cell neoprene foam panel gaskets, • Door gaskets in EPDM tube with...
Open the catalog to page 9A CAUTION: This configuration should be supplemented by cable inlet plates, ventilation plates and accessories on the next pages. 600 wide cabinet part numbers Part numbers in bold: available from stock. Normal type: check lead time with the sales representative. The OPTIMAL IP 21 cabinet comprises: • 1 galvanised steel Z275 riveted and screwed structure, • 2 panels screwed on crimped nuts (at 500 mm intervals) • 1 flat roof and 1 flat bottom in galvanised steel, with cut-outs (see page 14) • 4 inside uprights as per standards CEA-310E and IEC-60297, with marking of units on the 2 front...
Open the catalog to page 10PRECONFIGURATION IP 55 OPTIMAL Oblll/\IVr PRECONFIGURATION IP 55 The IP 55 cabinet is not designed for outdoor use. Please consult us for all outdoor applications. The OPTIMAL IP 55 cabinet comprises: • 1 galvanised steel Z275 riveted and screwed structure, • 2 panels screwed with neoprene gasket on crimped nuts (at 500 mm intervals), • 1 flat roof and 1 flat bottom in galvanised steel, with cut-outs (see page 16) • 4 inside uprights as per standards CEA-310E and IEC-60297, with marking of units on the 2 front uprights, • 4 adjustable feet, and fitted depending on circumstances: • At the...
Open the catalog to page 11OPTIMAL Oblll/\IVr PRECONFIGURATION EMC The OPTIMAL IP EMC cabinet comprises: • 1 galvanised steel Z275 riveted and screwed structure, • 2 panels screwed on crimped nuts (at 500 mm intervals) • 1 flat roof and 1 flat bottom in galvanised steel, with cut-outs (see page 18) • 4 inside uprights as per standards CEA-310E and IEC-60297, with marking of units on the 2 front uprights, • 4 adjustable feet, and fitted depending on circumstances: • At the front - with a solid door, - with a perforated door. • At the rear - with a solid door, - with a solid panel - with a perforated door. Glazed door...
Open the catalog to page 12OPTIMAL Oblll/\lVr PRECONFIGURATION HF PRECONFIGURATION HF The OPTIMAL IP HF cabinet comprises: • 1 galvanised steel Z275 riveted and screwed structure, • 2 panels screwed on crimped nuts (at 125 mm intervals) • 1 flat roof and 1 flat bottom in galvanised steel, with cut-outs (see page 20) • 4 inside uprights as per standards CEA-310E and IEC-60297, with marking of units on the 2 front uprights, • 4 adjustable feet, and fitted depending on circumstances: • At the front - with a solid door, - with a honeycomb door • At the rear - with a solid door, - with a solid panel - with a honeycomb...
Open the catalog to page 13IP 21 ENCLOSURES OPTIMAL Oblll/\IVr For customised configurations, select the components to create your own cabinet, complying with size constraints and desired protection levels. Supplement your selection with cable inlet plates, ventilation plates and accessories on page 24 and the following pages. Fait numbers in bold: available from stock. Normal type: check lead time with the sales representative.
Open the catalog to page 14IP 21 ENCLOSURES OPTIMAL Oblll/\IVr SIDE PANEL • Painted steel • Screwed to the structure. • IP 21 by labyrinth ring, without gasket. • Earthing by 4 mm2 braid, Fast-on locking connection. Part numbers REAR PANEL Ditto above. Part numbers DOORS • Painted steel • IP 21 by labyrinth ring, without gasket. • 1-position closing. • Reversible door unhingeable without tools. • Screwed to the structure. • V2 European cylinder exchangeable, supplied as standard in 455E • Earthing by 4 mm2 braid, Fast-on locking connection. Part numbers Machined doors are fitted with a solid panel and a perforated...