Datacenter

Datacenter
1 / 67 PagesView full catalog

Datacenter

Product catalog summary
Company Overview: ATOS specializes in designing and manufacturing enclosures for the electronics industry, including cabinets, cases, racks, and systems. With over 40 years of experience, they serve markets such as telecommunications, transportation, electronics, and IT, focusing on both civil and defense sectors. Their operations are based in Glos, Normandy, and Carros, French Riviera.
Design and Development: ATOS offers mechanical, electrical, and thermal dimensioning, power distribution, and cooling solutions using 3D CAD for design. They provide electrical design services tailored to the electronics market.
Prototyping and Testing: The company builds prototypes and ensures their industrialization, conducting environmental qualifications for electronics, telecommunications, and IT projects, including transport, IP or IK tests, and thermal tests.
Manufacturing: ATOS manufactures in France, adhering to European and French standards, ensuring consistent quality. Their facilities handle cutting, bending, welding, painting, and assembly.
Cooling Solutions: ATOS provides various cooling solutions, including Cold Contained Aisle (CCA), Hot Contained Aisle (HCA), and Contained Cabinet and Module (CCM), designed to optimize energy efficiency and reduce the carbon footprint of computer fleets.
Cooling System Details:
  • Cold Contained Aisle (CCA): Channels fresh air to the front of racks, preventing hot air return.
  • Hot Contained Aisle (HCA): Extracts and cools air using air/water exchangers.
  • Contained Cabinet and Module (CCM): Offers close-to-server cooling with redundancy options.
  • Passive and Active Cold Doors: Provide optimized regulation and enhanced hardware safety, with passive doors consuming less than 25 W and active doors supporting up to 45 kW per rack.
Project Management and Logistics: Dedicated personnel manage project progress and stock, maintaining direct customer contact.
Standards Compliance: ATOS products comply with standards such as IEC 297, EN 60-950, and IEA 310-E.
Active Cold Door (ACD): Capable of dissipating power ranging from 17 kW to 45 kW, offering flexible room layouts and compatibility with fire detection systems.
MODUL’X System: Facilitates the urbanization of computer rooms by drawing hot air from servers and cooling it through water-cooled doors.
Cooling Modules (ACM and CCM): Use air/water exchangers to cool hot air from servers, with power dissipation capacities of up to 45 kW.
Passive Cold Door (PCD): Designed for medium-density cooling solutions, dissipating 10 to 20 kW per rack.
Containment Systems: Improve energy efficiency and reduce carbon footprint by creating front and rear contained spaces.
Additional Features: Optional kits for water detection and redundant power supply, with various assembly components like sliding doors, roof panels, and cable trays.
Specifications:
  • Redundant Power Supply Kit: Ensures continuous power supply for critical systems.
  • Pressure Sensor Kit: Monitors and regulates pressure within systems.
  • Passive Door Benefits: Optimized regulation, low power consumption, enhanced safety, and optional communication protocols.
Modular Cabinet Solutions:
  • Convergence Cabinet: Designed for medium to high-density applications with high payload capacity.
  • Modul’x System: Modular solution for computer room urbanization.
Benefits:
  • Energy efficiency and reduced carbon footprint.
  • Flexible room layout and quick installation.
  • Compatibility with fire detection and extinguishing systems.
  • Reduced maintenance requirements and enhanced thermal efficiency.
Convergence Range: Includes various parts such as crossbars, uprights, brackets, doors, panels, and accessories, all compliant with international standards.
Specifications:
  • Crossbars: Made of painted steel, available in different depths and widths.
  • Uprights: Depth adjustable, made of galvanized steel.
  • Side Brackets: Used for vertical mounting of 19” hardware.
  • PDU Support Uprights: Allow "Zero U" PDU assembly.
  • Patching Comb: Used for cable management.
  • Grommet Seal Kit: Prevents air loops between cabinet front and rear.
  • Side Panels: Close cabinet sides, available with optional locks.
  • Doors: Feature 81% perforation for ventilation.
  • Handles: Different models available.
  • Roof Panels: Made from painted steel with cable inlet cut-outs.
  • Fans & Accessories: Various fan configurations available.
  • Backing Plates: Painted steel with cable cut-outs.
  • Caster Kits: Available for cabinet mobility.
  • Quick Hanging Rails: Made of galvanized steel.
  • Stabiliser: Provides safety and stability.
  • Raised Floor Support: Adjustable feet for height and load capacity.
Standards Compliance: All components conform to IEC 297, EN 60-950, and IEA 310-E standards.
Colocation Cabinets: Designed to support a static payload of 1200 kg, available in various formats and configurations.
Power Distribution Units (PDUs): Available in passive and active versions, with remote management capabilities.
Cabinet Pre-Fitting: Includes assembly and wiring services, with various cable management solutions.
Additional Features: Side panels, cable trays, front seal kits, and door contactors for monitoring and control.
19” Universal Accessories: Includes panels, enclosure lamps, and switches, with various configurations and features.
Main Distribution Frame Components: HPUL profiles for vertical or horizontal mounting.
Power Strips: Available for horizontal and vertical assembly, with various socket configurations.
Ventilation Louvers and Fans: Include louvers with filters and axial fans for enhanced airflow.
Grounding Kits and Fastenings: Include kits for cabinets and extensions, grounding terminal strips, and various fastening options.
Rack Specifications: Details on rack dimensions and configurations.
Contact Information: For sales and services, contact details for the France and Export office are provided.
See more

Catalog excerpts

Datacenter-2

EXPERIENCE designs, develops and manufactures enclosures for the electronics industry: cabinets, cases, racks, systems, fine sheet metal work, etc., in France, in its Glos (Normandy), and Carros (French Riviera) plants. For more than 40 years, ATOS has been working to provide an indoor or outdoor enclosure solution for every requirement in the electronics industry: standard, adapted standard, customized or production as per drawings. focus, ATOS serves the telecommunications, With its strong customer Transportation (aerospace, railway, aviation, navy, etc.), electronics and IT markets (OEM and...

 Open the catalog to page 2
Datacenter-3

has developed, in addition to its original sheet metal and modular mechanics businesses, a range of services enabling it to offer its customers DESIGN AND DEVELOPMENT ✓ Two design offices create standard, adapted, or customized products. ✓ Mechanical, electrical or thermal^B dimensioning: Power distribution, ✓ Air cooling, water-cooling syste up to 50kW pr cabinet, ✓ Solution architecture: Integration, power distribution, cooling, supervision. ✓ 3D CAD mechanical and sheet metal design. ✓ Electrical design: diagram creation. PROTOTYPING A focused and responsive organisation builds prototypes...

 Open the catalog to page 3
Datacenter-4

CONTENTS COOLING SOLUTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p. 6 to 14 COOLING SYSTEM PRESENTATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7 COLD CONTAINED AISLE “CCA”. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 HOT CONTAINED AISLE “HCA” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 CONTAINED CABINET AND MODULE “CCM”. . . . . . . . . . . . . . . . . ....

 Open the catalog to page 4
Datacenter-5

cooling system presentation Light or no cooling problems WITHOUT REAR Perforated doors for Convection (81% perforation) Contained Cold Aisle Contained Aisle with Aisle Cooling Module Rear desired: Medium Density = 6 to 15 kW Hot Contained Aisle Cold Contained Aisle Passive cold door. CCM MODUL’X Passive Cold Doors Horizontal section Rear CONTAINMENT Cabinet and Cabinet Cooling Modules Cabinet and Active Cold Doors MODUL’X Exchanger exhaust T° 34°C +/- 2°C (t: 12°C Outlet temperature

 Open the catalog to page 5
Datacenter-6

cooling system presentation VISUAL Servers Contained Aisle with Aisle Cooling Module Horizontal section

 Open the catalog to page 6
Datacenter-7

Cold contained aisle “cca” COLD CONTAINED AISLE “CCA” Principle: The pulsed fresh air in the raised floor is channelled to the front of the racks by closing the Cold Aisle: sliding end doors and removable glass roofs between two rows of racks. • Completely passive system. • The air inlet temperature is controlled over the entire height, no hot air is allowed to return to the front of the cabinets. • 1 0% of the air pulsed by the room air con0 ditioning units is used by the servers. Section This principle contributes to saving energy and improving the carbon footprint of computer fleets. COLD...

 Open the catalog to page 7
Datacenter-8

HOT CONTAINED AISLE “HCA” Principle: • The heated air leaving the servers is blown through the hot contained aisle. • The “ACM” aisle cooling modules extract the air from the aisle and cool it via an air/water exchanger. • he air flow is monitored by the pressure drop and T water flow by the outlet temperature setting • Close-to-server cooling system. • Ability to define the redundancy level: N+1 to 2N. • Air flow control enables optimum server operation. • Management: Alarm feedback by SNMP trap. SNMP-based ON/OFF mode management. data supervision by IMPI. Horizontal section This principle contributes...

 Open the catalog to page 8
Datacenter-9

CONTAINED CABINET AND MODULE ASSEMBLY, REAR CONTAINMENT ONLY Principle: A CCM consists of one or more cabinets and Cabinet Cooling Modules (“CCM”). The assembly is sealed by adding a Rear containment. Horizontal section Rear CONTAINMENT • Close-to-server cooling system. • Possible redundancy. • ir flow control enables optimum server operaA tion. • ore compact solution than an HCA from 1 to 4 M cabinets. • anagement: Alarm feedback by SNMP trap. M SNMP-based ON/OFF mode management. Data supervision by IMPI. 12 to 35 kW / rack Configuration example : 3 cabinets + 2 CCM Performance: Module cooling...

 Open the catalog to page 9
Datacenter-10

CONTAINED CABINET AND MODULE “CCM” COMPLETE ASSEMBLY, REAR FRONT-REAR Principle: A CCM consists of one or more cabinets and Cabinet Cooling Modules (“CCM”). The assembly is sealed by adding Front and Rear containments. Rear FRONT Horizontal section Rear CONTAINMENT • Close-to-server cooling system. • Possible redundancy. • ir flow control enables optimum server operation. A • ore compact solution than an HCA from 1 to 4 M cabinets. M • anagement: Alarm feedback by SNMP trap. SNMP-based ON/OFF mode management. Data supervision by IMPI. • The room does not need to be air conditioned. Performance:...

 Open the catalog to page 10
Datacenter-11

PASSIVE COLD DOOR Function: Rear door including an air-water exchanger, with a cooling capacity of 10 to 20 kW depending on the available water temperature. Pressure drop is very low and does not disrupt the servers. The heated air leaving the servers is cooled by a chilled water coil housed in the rear door. Coilrelated pressure drop remains within the limits recommended by server manufacturers: Pressure drop < 25 Pa Benefits of a passive door: • Optimised regulation. • Max power consumption <25 W • Enhanced hardware safety. • Communication: Modbus RTU or TCP/IP, SNMP optional Installation recommendations:...

 Open the catalog to page 11
Datacenter-12

WATER-COOLED CABINET Function: Cabinet fitted with a water-cooled door, capable of housing up to 45 kW of hardware without heating the outlet air and without disrupting server ventilation. The heated air leaving the servers is cooled by a chilled water coil housed in the rear door. Coilrelated pressure drop is conpensed by fans Benefits of a water-cooled door: • Optimised regulation. • anagement: Alarm feedback by SNMP trap. M SNMP-based ON/OFF mode management. Data supervision by IMPI. • Optimum power consumption < 800 W. • Enhanced hardware safety. • Specific features. The “ACD” Active Cold...

 Open the catalog to page 12