AT2503
2Pages

{{requestButtons}}

Catalog excerpts

AT2503 - 1

Monitoring of individual exposure doses from X-ray and gamma radiation with energy range from 50 keV to 1.5 MeV Applications ■ Radiation protective measures in case of nuclear disasters ■ Nuclear industry ■ Nuclear medicine ■ Radiology ■ Emergency situations ■ Civil aviation ■ Research activities ■ Dose monitoring of population Features Pocket-size intelligent devices, ideally matching accuracy, functionality, user friendliness, reliability and price. Dosimeter with reader, which is connected to PC, and software suite make an efficient automatic system for staff radiation exposure monitoring. Operating principle Primary dosimeter function is to measure Hp(10) individual dose equivalent, and the secondary one is to measure Hp(10) individual dose equivalent rate of X-ray and gamma radiation. Geiger-Muller counter tube with energy compensating filter is used as a detector. Intrinsic background metering and microprocessor processing provides high measurement accuracy. Microprocessor control of operation mode management, processing, display on TFT screen and self-check function. Integrated non-volatile memory allows recording and saving in deenergised state all accumulated dose data and dose accumulation history. ■ Simultaneous measuring of Hp(10) individual dose equivalent and Hp(10) individual dose equivalent rate of gamma radiation ■ Autocompensation of intrinsic detector background ■ Resistance to impacts and vibration, dust-and-moisture-proof, tolerance to electromagnetic interference ■ Constant detector self-check and battery level monitoring ■ Sound and LED alarm ■ Alarm mode for pulsed X-radiation detection with pulse length 10 ns and more (option) ■ Can be integrated into a system or used separately ■ Low weight and small size ■ Calibrated with water phantom ISO 30x30x15 cm ■ Dosimeter-to-PC communication via IR-transmitter in reader INSTRUMENTS AND TECHNOLOGIES FOR NUCLEAR MEASUREMENTS AND RADIATION MONITORING

Open the catalog to page 1
AT2503 - 2

Specification Detector Geiger-Muller counter tube Measurement range for: Individual dose equivalent AT2503, AT2503A 1 |jSv...10 Sv Intrinsic relative error for: Dose measurement ±(15+Hp(10)/50)%, where Hp(10) is dose rate in jSv/h Dose rate measurement ±(15+3.5^10-3/Hp(10)+Hp(10)/50)%, where Hp(10) is dose rate in jSv/h Normal energy relationship between dosimeter sensitivity and 137Cs gamma radiation energy of 662 keV Alarm thresholds 1 of 8 independent dose thresholds, 1 of 8 independent dose rate thresholds Anisotropy in angular spacing ±75° For 137Cs and 60Co ±20%...

Open the catalog to page 2

All Atomtex catalogs and technical brochures

  1. AT3509

    2 Pages

  2. AT6101

    2 Pages

  3. AT3201

    2 Pages

  4. AT1315

    2 Pages