PULSE ISOLATOR
1 / 4Pages

Catalog excerpts

PULSE ISOLATOR - 1

TECHNICAL DATA SHEET PULSE ISOLATOR SAFETY ACCESSORIE ATEX Interface for level switches - ATEX- IECEx- SIL 3 Technical characteristics : • 2 channels - 2 outputs • Cable error detection. • Up to SIL 3 in accordance with CEI 61508 • Input from area 0 (Area 20), safe in installation or in Area 2. • Galvanic isolation of 3 ports of the circuit, input / output / power . • Installation on a DIN rail, with or without Power Bus. • Power supply 24 Vdc (18 to 30 Vdc) • Pulse isolator with safety barrier for the supply of NAMUR sensors installed in the hazardous area • Pulse isolator with safety barrier for the detection of mechanical contacts installed in the hazardous area. • One input signal can be used on two separate outputs Mounting: • Mounted vertically or horizontally on a DIN rail up to 84 channels per meter can be mounted Certifications: • ATEX, IEC Ex, DNV, INMETRO, NEPSI, GOST, TRCU, TCCExEE, Korean Register, CCOE Indian, Rostehnadzor, • TUV SIL Functional Safety Certificate ATMI - ZA de I'observatoire - 2, avenue des Bosquets - 78180 MONTIGNY LE BRETONNEUX - FRANCE Tel. : +33 (0)1 61 37 35 60 - Fax : +33 (0)1 61 37 35 69 - @mail: sales@atmi.fr web site: www.atmi.fr

Open the catalog to page 1
PULSE ISOLATOR - 2

PULSE ISOLATOR TECHNICAL DATA SHEET SIL 3 Switch/Proximity Detector Repeater, Relay Ouput Din-Rail Models D5030S, D5030S Characteristics Technical data: Gimril OuscrFplian: The sngle and dual channel SwttchTPmximrty Detector Repealer, D5030S and 050300 module is a unit suitable for applications requiring SIL 3 level (according to IEC 61508:2010 Ed. 2) in safety related systems for high risk industries. The unit can ba configured lor switch or proximity detector (EN60947-5-6. NAMUR). NO or NC end lor NE or ND SPST (D5D30D) or SPOT (D503OS) relay output contact Each channel enables a Safe...

Open the catalog to page 2
PULSE ISOLATOR - 3

PULSE ISOLATOR TECHNICAL DATA SHEET PARAMETERS : Maximum External Parameters Safety description Groupe Cenelec FUNCTION DIAGRAM: HAZARDOUS AREA ZONE 0 (ZONE 20) GROUP IIC,HAZARDOUS LOCATIONS CLASS I, DIVISION 1, GROUPS A, B, C, D,CLASS II, DIVISION 1, GROUPS E, F, G, CLASS III, DIVISION 1,CLASS I, ZONE 0, GROUP IIC SAFE AREA, ZONE 2 GROUP IIC T4,NON HAZARDOUS LOCATIONS, CLASS I, DIVISION 2, GROUPS A, B, C, D T-Code T4, CLASS I, ZONE 2, GROUP IIC T4 ATMI – ZA de l’observatoire - 2, avenue des Bosquets - 78180 MONTIGNY LE BRETONNEUX - FRANCE Tél. : +33 (0)1 61 37 35 60 - Fax : +33 (0)1 61 37...

Open the catalog to page 3
PULSE ISOLATOR - 4

PULSE ISOLATOR HAZARDOUS AREA ZONE 0 (ZONE 20) GROUP IIC, HAZARDOUS LOCATIONS CLASS I, DIVISION 1, GROUPS A, B, C, D, CLASS II, DIVISION 1, GROUPS E, F, G, CLASS III, DIVISION 1, CLASS I, ZONE 0, GROUP IIC TECHNICAL DATA SHEET SAFE AREA, ZONE 2 GROUP IIC T4, NON HAZARDOUS LOCATIONS, CLASS I, DIVISION 2, GROUPS A, B, C, D T-Code T4, CLASS I, ZONE 2, GROUP IIC T4 Relay contact shown in de-energized position. Contacts relais montrés en position non alimenté. Terminals 1-2 and 3-4 open. Contact ouvert bornes 1-2 et 3-4 SAFE AREA, ZONE 2 GROUP IIC T4, NON HAZARDOUS LOCATIONS, CLASS I, DIVISION...

Open the catalog to page 4

All ATMI catalogs and technical brochures

  1. SOLIBA PRA

    2 Pages

  2. SOLIBA PRP

    2 Pages

  3. SOLIBA M

    2 Pages

  4. FIX-CAB

    1 Pages

  5. PIEZO ST

    1 Pages

  6. Cable clamps

    1 Pages

  7. AQUA MEDIUM

    2 Pages

  8. TUBA 125C

    2 Pages

  9. SOLIBA EX GP

    2 Pages

  10. SOLIBA EX P

    2 Pages

  11. SOLIBA

    2 Pages

  12. BIP STOP

    2 Pages

  13. AQUA XL

    2 Pages

  14. SOBA HR HY

    2 Pages

  15. SOBA SMALL

    2 Pages

  16. PIEZO AS

    1 Pages

  17. CABLE CLAMP

    1 Pages

Archived catalogs