Technical Specifications
  • Allowed Fluid Densities: 0.70 to 1.15 g/cm³
  • Electric Characteristics: 12, 24, 48 V AC/DC, 250 V AC - 50/60 Hz
  • Cut-out Power: 16 (6) A
  • Maximum Pressure: 3.5 bars
  • Maximum Temperature: 85 °C
  • Protection Index: IP 68
  • Housing Material: Copolymer polypropylene
  • Type of Cable: Neoprene, HR HY
  • Float Weight without Cable: 200 g
Product Description

The SOBA level regulator with external ballast is designed for use in waste water and sewage systems. It detects the liquid level by the tilting of the float, which activates a mechanical contact to open or close the circuit, controlling the operation of a pump or alarm. It is suitable for use in sewage lifting stations.

Operation
  • Emptying: The liquid reaches the float, which tilts and signals the pump to start emptying. Pumping stops when the regulator returns to the vertical position.
  • Filling: The pump fills the tank. Filling starts when the regulator returns to the vertical position and stops when the high-level regulator switches.
See more

Catalog excerpts

Data sheet - Float level switch regulator - SOBA-1

FICHE TECHNIQUE - TECHNICAL SHEET- FICHA TECNICA LE SPECIALJSTE DE LA REGULATION PAR FLOTTEUR SOBA % ) - REGULATEUR DE NIVEAU LESTE SUR CABLE Pour eaux usees, eaux chargees Ce regulateur de niveau detecte I'atteinte d'un niveau par basculement du flotteur ce qui actionne le contact relie a une armoire de commande, fermant ou ouvrant le circuit d'alimentation de pompes ou autres. Il est parfaitement adapte pour une utilisation dans des stations de relevage d'eaux usees et d'egouts. - LEVEL REGULATOR WITH EXTERNAL BALLAST For waste water, sewage This level regulator is designed for charged liquids. When the liquid reaches the regulator, the pear tilts and the mechanical contact will close or open the circuit, thus controlling the stop or the starting of a pump or an alarm. Densites de fluides admissibles Allowed fluid densities 0,70 a 1,15 g/cm3 Densidad fluidos Caracteristiques electriques Electric characteristics Caracteristicas electricas - REGULATOR DE NIVEL CON LASTRE EXTERNO Para aguas residuales Este controlador de nivel detecta el nivel alcanzado al inclinar el flotador que dispara el contacto conectado a un gabinete de control, cerrando o abriendo el circuito de suministro de bomba u otro. Es ideal para su uso en alcantarillas Pouvoir de coupure Cut-out power 16 (6) A Capacidad de corte Pression de service admissible Maximum pressure 3,5 bars Presion maxima Temperature maxi Maximum temperature 85 °C Temperatura maxima Indice de protection Protection index IP 68 ]□] Indice de proteccion Corps Polypropylene copolymere Housing Copolymer polypropylene Cuerpo Polipropileno Type de cable Neoprene, HR HY Type of cable Neoprene, HR HY Tipo de cable Neopreno, HR HY Poids flotteur sans cable Float weight without cable 200 g Peso flotador sin cable +/-25 Angle - Angulo Dimension - Dimension 1/2 Doc.Tec-4404-12/18-FR/GB/ESP ATMI -ZA de I'observatoire -2, avenue des Bosquets -78180 MONTIGNY LE BRETONNEUX - FRANCE -Tel. : +33 (0)1 61 37 35 60 -Fax : +33 (0)1 61 37 35 69 - @mail : [email protected] web site : www.atmi.fr

 Open the catalog to page 1
Data sheet - Float level switch regulator - SOBA-2

FONCTIONNEMENT – OPERATION – FUNCIONAMIENTO VIDANGE – EMPTYING - VACIADO ON Le liquide atteint le flotteur qui en basculant donne le signal à la pompe de démarrer pour la vidange Le pompage permet de vider le liquide. Le pompage s'interrompt dès que le régulateur bas revient en position verticale The liquid reaches the float which by tilting gives the signal to the pump to start for emptying Pumping allows to empty the liquid The pumping stops as soon as the low regulator returns to the vertical position El líquido llega al flotador que, al inclinarse, da la señal a la bomba para que comience...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.