Bimed begun in 1978 as a manufacturer of medical and mechanical components. Today Bimed is a family owned organization with more than 300 people and a 20,000 square meter facility. The Istanbul, Turkey-based company has offices in North America, Germany and Egypt. In many other countries Bimed is represented through local distribution partners. Our product range consists of the following groups: • Cable glands and conduit fittings • Pressure balance elements • Connectors for the appliance and automotive industries • Gas springs for the automotive and furniture industries • Disposable...
Open the catalog to page 2Mining - Group I Ex I M2 Ex d I Mb Ex e I Mb Dorado M-BA 4 Function Glands 05-06 Gas & Dust - Group II-III Ex II GD Ex d IIC Gb Ex e IIC Gb Ex tb III Db Dorado BA 4 Function Glands 11-12 Gas & Dust - Group II-III Orion Universal KBAU 4 Function Glands Orion Offshore KBAO 4 Function Glands E-Carina EBM Rigid Conduit Fittings E-Cygnus EBMC Rigid Conduit Fittings Phoenix SV Swivel Rigid Conduit Fittings E-Hydrus EBLS Liquidtight Conduit Fittings E-Scorpius EBLQ 45° Liquidtight Conduit Fittings E-Lupus EBLN 90°...
Open the catalog to page 3When miners worked an 8-hour shitt pattern, the mined coal would be left in the shaft until the next day. during which time the methane would start to be evolved into the air in the shaft. The methane would collect in pockets at the roof of the mine and form an explosive layer. The mines returning for the next shift would carry with them the means of igniting the gas. hat mounted candles, and hand carried oil lanterns. The resulting ignition of the methane would in itself not necessarily be fatal for the miners. It was the secondary ignition of coal dust, throw up into a cloud by the...
Open the catalog to page 4ATEX Group I / Mining / Ex I M2 / Ex d I Mb - Ex e I Mb
Open the catalog to page 6UPPER SEAL CABLE OUTER DIAMETERS D1 <-► LOWER SEAL CABLE INNER DIAMETERS ATEX Group I / Mining / Ex I M2 / Ex d I Mb - Ex e I Mb
Open the catalog to page 7Orion 4 Function Ex d/e Gland Approved by ATEX Group I / Mining / Ex I M2 / Ex d I Mb - Ex e I Mb
Open the catalog to page 8ATEX Group I / Mining / Ex I M2 / Ex d I Mb - Ex e I Mb
Open the catalog to page 9Groups II & III are further sub-divided depending upon the hazard.Group II gases are grouped together based upon the amount of energyrequired to ignite the most explosive mixture of the gas with air. Group III dusts are subdivided according to the nature of the explosive atmosphere for which it is intended. Ex d Flameproof The equipment that may cause an explosion is contained within an enclosure which can withstand the force of an explosion and prevent transmission to the outside hazardous atmosphere. This method of protection also prevents the hazardous atmosphere from entering the...
Open the catalog to page 1011 ATEX Group / Gas & Dust / Ex II 2 GD / Ex d IIC Gb - Ex e IIC Gb - Ex tb III Db
Open the catalog to page 12UPPER SEAL CABLE OUTER DIAMETERS D1 <-► LOWER SEAL CABLE INNER DIAMETERS ATEX Group / Gas & Dust / Ex II 2 GD / Ex d IIC Gb - Ex e IIC Gb - Ex tb III Db
Open the catalog to page 1313 ATEX Group / Gas & Dust / Ex II 2 GD / Ex d IIC Gb - Ex e IIC Gb - Ex tb III Db
Open the catalog to page 14UPPER SEAL CABLE OUTER DIAMETERS LOWER SEAL CABLE INNER DIAMETERS ATEX Group / Gas & Dust / Ex II 2 GD / Ex d IIC Gb - Ex e IIC Gb - Ex tb III Db
Open the catalog to page 1515 ATEX Group / Gas & Dust / Ex II 2 GD / Ex d IIC Gb - Ex e IIC Gb - Ex tb III Db
Open the catalog to page 16UPPER SEAL CABLE OUTER DIAMETERS D1 ATEX Group II - III / Gas & Dust / Ex II 2 GD / Ex d IIC Gb - Ex e IIC Gb - Ex tb III Db
Open the catalog to page 1717 ATEX Group / Gas & Dust / Ex II 2 GD / Ex d IIC Gb - Ex e IIC Gb - Ex tb III Db
Open the catalog to page 18ATEX Group II - III / Gas & Dust / Ex II 2 GD / Ex d IIC Gb - Ex e IIC Gb - Ex tb III Db
Open the catalog to page 19Explosive gases, vapors and dusts have different chemical properties that affect the likelihood and severity of an explosion. Such properties include flame temperature, minimum ignition energy, upper and lower explosive limits, and molecular weight. Empirical testing is done to determine parameters such as the maximum experimental safe gap. minimum ignition current, explosion pressure and time to peak pressure, spontaneous ignition temperature, and maximum rate of pressure rise. Every substance has a differing combination of properties but it is found that they can be ranked into similar...
Open the catalog to page 20IECEx ATEX Group II-III / Gas & Dust / Ex II 2 GD / Ex d IIC Gb - Ex e IIC Gb - Ex tb III Db
Open the catalog to page 22Orion 4 Function Ex d/e Gland Equipment Order Encoding UPPER SEAL CABLE OUTER DIAMETERS LOWER SEAL CABLE INNER DIAMETERS IECEx ATEX Group II-III / Gas & Dust / Ex II 2 GD / Ex d IIC Gb - Ex e IIC Gb - Ex tb III Db
Open the catalog to page 23IECEx ATEX Group II-III / Gas & Dust / Ex II 2 GD / Ex d IIC Gb - Ex e IIC Gb - Ex tb III Db
Open the catalog to page 24UPPER SEAL CABLE OUTER DIAMETERS LOWER SEAL CABLE INNER DIAMETERS IECEx ATEX Group II-III / Gas & Dust / Ex II 2 GD / Ex d IIC Gb - Ex e IIC Gb - Ex tb III Db
Open the catalog to page 25IECEx ATEX Group II-III / Gas & Dust / Ex II 2 GD / Ex d IIC Gb - Ex e IIC Gb - Ex tb III Db
Open the catalog to page 26UPPER SEAL CABLE OUTER DIAMETERS LOWER SEAL CABLE INNER DIAMETERS IECEx ATEX Group II-III / Gas & Dust / Ex II 2 GD / Ex d IIC Gb - Ex e IIC Gb - Ex tb III Db
Open the catalog to page 27Auto ignition temperatures The auto ignition temperature of a liquid, gas or vapor is the temperature at which the substance will ignite without any external heat source. The exact temperature value determined depends on the laboratory test conditions and apparatus. Such temperatures fo common substances are: The surface of a high pressure steam pipe may be above the autoignition temperature of some fuel/air mixtures. Auto ignition temperatures (dust) The auto ignition temperature of a dust is usually higher than that of vapours & gases. Examples for common materials are: Substance...
Open the catalog to page 2829 ATEX Group / Gas & Dust / Ex II 2 GD / Ex d IIC Gb - Ex e IIC Gb - Ex tb III Db
Open the catalog to page 30Seal and Pressure ring CABLE OUTER DIAMETERS , D1 , <-► ATEX Group II - III / Gas & Dust / Ex II 2 GD / Ex d IIC Gb - Ex e IIC Gb - Ex tb III Db
Open the catalog to page 3131 ATEX Group / Gas & Dust / Ex II 2 GD / Ex e IIC Gb - Ex tb III Db
Open the catalog to page 32ATEX Group II - III / Gas & Dust / Ex II 2 GD / Ex e IIC Gb - Ex tb III Db Thread Type (TD) Clamping Range (D) Sealing Combinations
Open the catalog to page 33All Atexxo Manufacturing B.V. catalogs and technical brochures
-
ATEX Samsung 10.9
2 Pages
-
ATEX iPhone 15
2 Pages
-
ATEX iPad Mini 6
2 Pages
-
Atex iPad 10.9
2 Pages
-
Ex Zone 1 iPhone 14
2 Pages
-
EX Zone 1 iPhone 13
2 Pages
-
ATEX iPhone 13
2 Pages
-
ATEX iPhone 12
2 Pages
-
ATEX iPad Mini 4
2 Pages
-
ATEX iPad Mini 5
2 Pages
-
ATEX iPad 10.2
2 Pages
-
IECEx Ipad Mini 5
2 Pages
-
EX Zone 1 iPhone 11
2 Pages
-
ATEX iPhone SE
2 Pages
-
ATEX iPhone 11
2 Pages
-
ATEX Watch S5
2 Pages
-
EX Proof AC units
3 Pages
-
ATEX iPhone XS
2 Pages
-
ATEX AC Units R32
3 Pages
-
Cable-Glands-ATEX -IECEX-DNV-GL
114 Pages
-
ATEX-LED-SPOT-12V-EX
2 Pages
-
ATEX-LED-LIGHT-230V-EX
2 Pages