Company Overview: Bimed, founded in 1978, is a family-owned manufacturer based in Istanbul, Turkey. It operates a 20,000 square meter facility with over 300 employees and has expanded globally with offices in North America, Germany, and Egypt, and distribution partners in over 30 countries.
Product Range: Bimed offers cable glands, conduit fittings, pressure balance elements, connectors for appliances and automotive industries, gas springs for automotive and furniture industries, and disposable medical products. All products comply with national and international standards, including EN ISO 9001:2008.
Quality and Certifications: Bimed is known for high-quality production, supported by a certified laboratory and over 30 years of experience. The company holds ATEX 100 and IEC Ex factory approvals and has a laboratory certified by IMQ for hazardous areas.
Customer Satisfaction and Innovation: Bimed prioritizes customer satisfaction by offering standard and customized products. Its R&D department develops new items based on client demands, enhancing customer loyalty.
Distribution Network: Bimed's global distribution network ensures market understanding and satisfaction, establishing it as a leader in the cable gland and connector sector.
Technical Specifications: The document details specifications for cable glands, including Dorado and Orion models, with information on clamping ranges, dimensions, materials, and certifications. These products are designed for mining and potentially explosive atmospheres, offering high strain relief, IP ratings, and explosion-proof protection.
Key Features: The cable glands feature a unique design for easy inspection and maintenance without damaging cables. They are deluge-proof, with multiple O-rings preventing water intrusion, suitable for a wide range of cable diameters and available in various thread types and materials.
Specifications: The document details specifications for cable glands designed for potentially explosive atmospheres, compliant with ATEX Group II - III standards for gas and dust environments. They provide high strain relief, IP66-IP68 protection, and explosion-proof features due to unique seal designs.
Design and Features: The cable glands have a special shape of seals, allowing for a wide range of cable diameters. They are equipped with uniform hexagon nuts, reducing the need for multiple wrench sizes. The glands are deluge-proof, with water intrusion trapped between two o-rings on the grounding cone.
Materials and Construction: Materials include brass and stainless steel, with options for nickel plating. Seals are made from NBR, chloroprene, or silicone, with operating temperatures ranging from -60°C to +180°C.
Certification and Standards: The glands are approved by IMQ with examination certificates and comply with safety requirements EN 60079-0:2009, EN 60079-1:2007, EN 60079-7:2007, and EN 60079-31:2009. They are suitable for use in Zone 1/Zone 2 and Zone 21/Zone 22 environments.
Order Encoding and Variants: The document provides order encoding for different thread types (Metric and NPT), materials, and sealing options, including a table of clamping ranges and dimensions for various gland sizes.
Applications: These cable glands are suitable for use with steel wire armor and lead-sheathed cables in environments with gas and dust explosion risks, offering robust protection and flexibility for industrial applications.
Technical Document Summary:
1. Specifications and Product Details: Detailed specifications for cable glands, including thread types, material options, and sealing options. Specific models with clamping ranges, dimensions, and applicable standards are listed.
2. Auto Ignition Temperatures: Outlines auto ignition temperatures for various gases and dusts, indicating ignition temperatures without an external heat source.
3. Safety and Certification: Includes safety requirements and certifications such as ATEX and IECEx approvals, specifying equipment marking for use in potentially explosive atmospheres.
4. Equipment Marking and Usage: Equipment is marked for use in Gas Group IIC and Dust Group IIIC, suitable for Zones 1/2 and 21/22, detailing marking codes and protection degrees.
5. Order Encoding and Material Options: Provides order encoding examples for specifying thread type, material, and sealing options, mentioning customized high-temperature applications.
6. Function and Components: Describes the function of various gland types and lists components like O-rings, seals, and pressure rings.
Overview: The document provides specifications and guidelines for Ex e and Ex d/e fittings used in potentially explosive atmospheres, covering cable glands, rigid conduit fittings, and swivel fittings.
Specifications: Lists components such as O-rings, seals, lower bodies, caps, and cables, detailing materials and thread types available.
Procedures: Outlines the order encoding system for specifying fittings, providing tables with dimensions and clamping ranges.
Standards and Certifications: Complies with safety standards, approved by IMQ with examination certificate numbers and test report numbers.
Recommendations: Emphasizes selecting the correct fitting type and material based on the application environment, highlighting proper sealing combinations.
Key Data from Tables: Provides dimensions for each fitting type, including clamping range, fitting dimensions, and seal dimensions.
Critical Information: Suitable for use in Zone 1/Zone 2 and Zone 21/Zone 22 environments, with protection rated at IP66 – IP68.
Overview: Provides specifications and guidelines for cable glands used in potentially explosive atmospheres, focusing on material composition, sealing capabilities, and compliance with safety standards.
Specifications: Designed for Group II and Group III environments, offering protection rated IP66 to IP68, with specified operating temperature ranges for different seal materials.
Materials and Construction: Constructed from materials like brass, stainless steel, aluminum, and polyamide, detailing impact and UV resistance.
Thread Types and Dimensions: Lists thread types available, providing tables with clamping ranges and dimensions for different gland models.
Safety and Compliance: Complies with safety requirements outlined in standards, marked with Ex II 2 GD, and includes certification details from IMQ and IECEx.
Applications and Recommendations: Recommended for intrinsically safe circuits, emphasizing selecting the appropriate gland type based on environmental conditions and cable specifications.
Overview: Provides technical specifications and guidelines for metal fittings, including O-rings, bodies, and thread types, focusing on products suitable for potentially explosive atmospheres.
Specifications: Outlines specifications for different thread types, facilitating selection for various applications.
Code Generation: Provides a table to generate codes based on type, thread sizes, and material.
Safety and Compliance: Emphasizes compliance with IECEx and ATEX standards, specifying protection types and degrees.
Material and Temperature: Materials include Brass, Stainless Steel, and Galvanized Steel, with specified operating temperatures.
Certification and Testing: Includes certification details, aligning with safety requirements.
Dimensional Data: Provides dimensions for various configurations, ensuring precise fitting and compatibility.
Specifications and Standards: References IEC standards for equipment in explosive atmospheres, indicating suitability for hazardous areas.
Equipment Marking and Protection: Marked for use in Group II and III hazardous areas, with specified protection types and degrees.
Materials and Construction: Uses materials like brass, stainless steel, and polyamide for components, chosen for durability.
Accessories and Components: Details accessories like earth tags, shrouds, and gaskets, each with specific properties.
Explosion Proof Information: Equipment designed to prevent ignition of explosive atmospheres, with strategies for prevention and compliance with international standards.
Order Encoding and Dimensions: Provides order encoding for components, specifying thread types, sizes, and materials.
Area Classification and Equipment Ratings: Outlines process for identifying equipment ratings and installation techniques for classified areas, involving professionals and updated for process changes.
Historical Context: Highlights the need for safe electrical systems in hazardous environments due to historical explosions.
Abbreviations: Includes terms like SWA and AWA, describing cable types and functions.
Explosion Proof Information: Details gas divisions or zones, non-hazardous areas, and classifications based on gas or vapor presence.
Gas Groups: Classifies gases into groups based on volatility and ignition energy, guiding equipment selection.
Equipment Protection Level (EPL): Specifies protection levels for equipment based on zone usage, with different protection types.
Temperature Classification: Classifies electrical equipment by surface temperature to ensure safety.
Auto-Ignition Temperatures: Lists ignition temperatures for gases and dusts.
Types of Protection: Details protection methods for equipment, suitable for different zones.
Multiple Protection: Equipment may use multiple protection methods, labeled accordingly.
ANSI/NFPA Area Descriptions: Defines classes and divisions for areas based on flammable presence.
Classification of Hazardous Areas: Divides areas into groups based on dust types, with detailed information in NFPA 70.
Equipment Categories: Categorizes equipment based on protection level for different zones.
Labeling Requirements: Specifies labeling for equipment in Europe and North America.
IP Classification Codes: Defines protection levels against objects and moisture.
Explosion Proof Information: Explains explosion prevention measures and types of explosion protection.
Potentially Explosive Atmospheres: Defined as mixtures of flammable substances with air that can ignite.
Area Classification: Classifies areas based on flammable substance presence to minimize ignition risks.
Area Classification (Zones): Divides facilities into hazardous and non-hazardous areas, with zones based on explosive atmosphere likelihood.
Classification Society: Societies may impose additional design requirements for installations.
Design and Installation of Electrical Systems: Governed by regulations and standards, selection depends on classification, temperature, and external influences.
Apparatus Selection According to Zones: Specifies apparatus for different zones, with standards for combustible dust.
Apparatus Selection by Ignition Temperature: Equipment must not exceed ignition temperature of gases or vapours.
Apparatus Grouping: Classifies gases and vapours into groups for equipment selection.
Device Category: Determines device categories by zone and safety level.
Equipment Protection Level (EPL): Divides devices into protection levels for different zones and mine workings.
See more

Catalog excerpts

Cable-Glands-ATEX -IECEX-DNV-GL-1

CABLE GLANDS & ACCESSORIES Trademark for Innovation & Quality

 Open the catalog to page 1
Cable-Glands-ATEX -IECEX-DNV-GL-2

Our Company Bimed begun in 1978 as a manufacturer of medical and mechanical components. Today Bimed is a family owned organization with more than 300 people and a 20,000 square meter facility. The Istanbul, Turkey-based company has offices in North America, Germany and Egypt. In many other countries Bimed is represented through local distribution partners. Our product range consists of the following groups: Cable glands and conduit fittings Pressure balance elements Connectors for the appliance and automotive industries Gas springs for the automotive and furniture industries Disposable medical...

 Open the catalog to page 2
Cable-Glands-ATEX -IECEX-DNV-GL-3

Content Certificate and Group 4 Function Glands 4 Function Glands Gas & Dust - Group II-III Ex II GD Ex d IIC Gb Ex e IIC Gb Ex tb III Db Dorado BA L-Dorado BA-L Orion KBA Octans BU 4 Function Glands 4 Function Glands 4 Function Glands 1 Function Glands Gas & Dust - Group II-III Ex II GD Ex d IIC Gb Ex e IIC Gb Ex tb III Db Orion KBA Orion Universal KBAU Orion Offshore KBAO 4 Function Glands 4 Function Glands 4 Function Glands Crater E-Octans E-Vela Norma 1 Function Glands 1 Function Glands 1 Function Glands 1 Function Glands E-Carina E-Cygnus Phoenix Rigid Conduit Fittings Rigid Conduit Fittings...

 Open the catalog to page 3
Cable-Glands-ATEX -IECEX-DNV-GL-4

MINING applications The first hazardous area was discovered in the early coal mines* This area held a double hazards melhane gas (firedamp] ond coal dust. Methane gas is absorbed in the pores of coaL When the coal is mined the methane is evolved, a process fiat takes a relatively short time. To be completely free of methane, coal has to be store for a period of up to When miners worked an 8-hour shift pattern, the mined coal woufd be left in the shaft until the next day. during which time the melhane would start to be evolved inlo the air in the shaft. The methane would collect in packets al...

 Open the catalog to page 4
Cable-Glands-ATEX -IECEX-DNV-GL-6

Dorado 4 Function Ex d/e Gland Approved by Examination Certificate Number Date of Issue Test Report Number Safety Requirements Equipment Marking Approved Equipment Item Description O-ring Lower body Lower seal O-ring Grounding cone O-ring O-ring Swivel retainer Upper body Washer Upper seal Pressure Cap Armored wire Armored Cable GOST"R" Mining Group ZONE1/ZONE2 No need to change, to remove or to adjust any internal components as long as the diameter of the used cable is within the declared clamping range. The swiveling “shielding cone” (5) for clamping armor is secured to the “upper body” (9)...

 Open the catalog to page 6
Cable-Glands-ATEX -IECEX-DNV-GL-7

Dorado 4 Function Ex d/e Gland Suitable for use in For Degree of Protection Marking Deluge Proof Option Cable Type Seal Operating Nbr Temperature Chloroprene Silicone Material Thread Type Group I Mining IM2 Mining potentially explosive atmospheres IP66 – IP68 (EN 60529) BMD M-BA.. Ex CE 0722 I M2 Ex-d I Mb / Ex-e I Mb Ta-30°C +120°C IP66/68 IMQ 10 ATEX 036 Standard Steel wire armor -30°C / +120°C -40°C / +100°C Items 1-3-4-6-7-11 -60°C / +180°C Brass Items 2-5-8-9-12 Stainless Steel Metric (M) ISO Pitch 1,5 Npt (N) ANSI ASME B1.20.1 Other thread types also available upon request. Order Encoding...

 Open the catalog to page 7
Cable-Glands-ATEX -IECEX-DNV-GL-8

Orion 4 Function Ex d/e Gland Approved by Examination Certificate Number Date of Issue Test Report Number Safety Requirements Equipment Marking Approved Item Description O-ring Lower body Lower seal O-ring Grounding cone Swivel retainer O-ring Upper body Upper seal Pressure Cap Armored wire Armored cable IMQ IMQ 11 ATEX 037 16.01.2012 43AL00047 EN 60079-0:2009 EN 60079-1:2007 EN 60079-7:2007 EN 60079-11:2010 EN 60079-31:2009 Ex-d I Mb Ex I M2 Ex-e I Mb GOST"R" - INMETRO ATEX Group I / Mining / Ex I M2 / Ex d I Mb - Ex e I Mb

 Open the catalog to page 8
Cable-Glands-ATEX -IECEX-DNV-GL-9

Orion 4 Function Ex d/e Gland Equipment Suitable for use in For Degree of Protection Marking Cable Type Seal Operating Temperature Material Thread Type Mining Group ZONE1/ZONE2 Group I Mining IM2 Mining potentially explosive atmospheres IP66 – IP68 (EN 60529) BMD M-KBA.. Ex CE 0722 I M2 Ex-d I Mb / Ex-e I Mb Ta-40°C +100°C IP66/68 IMQ 11 ATEX 037 Steel wire armor -40°C / +100°C Items 1-3-4-7-9 -60°C / +180°C -30°C / +120°C Brass Items 2-5-6-8-10 Stainless Steel Metric (M) ISO Pitch 1,5 Npt (N) ANSI ASME B1.20.1 Other thread types also available upon request. Order Encoding Type Thread M-KBA01...

 Open the catalog to page 9
Cable-Glands-ATEX -IECEX-DNV-GL-10

Groups II & III are further sub-divided depending upon the hazard.Group II gases are grouped together based upon the amount of energyrequired to ignite the most explosive mixture of the gas with air. Group III dusts are subdivided according to the nature of the explosive atmosphere for which it is intended. The equipment that may cause an explosion is contained within an enclosure which can withstand the force of an explosion and prevent transmission to the outside hazardous atmosphere. This method of protection also prevents the hazardous atmosphere from entering the enclosure and coming into...

 Open the catalog to page 10
Cable-Glands-ATEX -IECEX-DNV-GL-12

Dorado 4 Function Ex d/e Gland Approved by Examination Certificate Number Date of Issue Test Report Number Safety Requirements Equipment Marking Ex II 2 GD Approved Item Description O-ring Lower body Lower seal O-ring Grounding cone O-ring O-ring Swivel retainer Upper body Washer Upper seal Pressure Cap Armored wire Armored Cable No need to change, to remove or to adjust any internal components as long as the diameter of the used cable is within the declared clamping range. The swiveling “shielding cone” (5) for clamping armor is secured to the “upper body” (9) and “lower body” (2) by orings...

 Open the catalog to page 12
Cable-Glands-ATEX -IECEX-DNV-GL-13

Dorado 4 Function Ex d/e Gland Equipment Suitable for use in For Degree of Protection Marking Deluge Proof Option Cable Type Seal Nbr Operating Chloroprene Temperature Silicone Material Thread Type Gas Group Dust Group ZONE1/ZONE2 ZONE21/ZONE 22 Group II Group III Gas Group IIC Dust Group IIIC Gas & Dust potentially explosive atmospheres IP66 – IP68 (EN 60529) BMD BA.. Ex CE 0722 II 2GD Exd IIC GB / Exe IIC Gb / Ex tb IIIC Db Ta-30°C +120°C IP66/68 IMQ 10 ATEX 036 Standard Steel wire armor -30°C / +120°C Items 1-3-4-6-7-11 -40°C / +100°C -60°C / +180°C Brass Items 2-5-8-9-12 Stainless Steel Metric...