Data sheet ©2026, ATESTEO GmbH & Co. KG, This product data sheet was created on 02.05.2026. The information contained in the product data sheet corresponds to the status quo at the time the document was created. ATESTEO continually further develops its products and reserves the right to make changes to the technical data. ATESTEO does not accept any liability for consequential losses arising from the use of this product data sheet or the information contained therein.
Open the catalog to page 1MLTechnical data Type - ML Torque measuring system Test signal Angular measuring system Analogue voltage output Max. rotation count Angular speed measuring system Analogue voltage output Torque accuracy class per output type (related to Mdn) Frequency output CAN output Voltage output Frequency (TTL), Voltage, CAN bus see test report ©2026, ATESTEO GmbH & Co. KG, This product data sheet was created on 02.05.2026. The information contained in the product data sheet corresponds to the status quo at the time the document was created. ATESTEO continually further develops its products and reserves...
Open the catalog to page 2MLTechnical data Type - ML Linearity deviation including hysteresis related to Mdn Rel. standard deviation of the reproducibility according to DIN 1319, by reference to variation of the output signal (rel. to Mdn) Temperature influence per 10K in the nominal temperature range on the output signal related to the actual value of signal span (rel. to Mdn) Temperature influence per 10K in the nominal temperature range on the zero signal (rel. to Mdn) Long-term drift over 48h at reference temperature Voltage output ©2026, ATESTEO GmbH & Co. KG, This product data sheet was created on 02.05.2026. The...
Open the catalog to page 3ML Technical data Type Accuracy class Rated torque (Mdn) Nominal sensitivity (range between zero torque and rated torque) Output signal at zero torque Nominal output signal Frequency output at positive nominal value kHz Frequency output at negative nominal value kHz Voltage output at positive nominal value V Voltage output at negative nominal value V Group delay time (main TCU) ©2026, ATESTEO GmbH & Co. KG, This product data sheet was created on 02.05.2026. The information contained in the product data sheet corresponds to the status quo at the time the document was created. ATESTEO continually...
Open the catalog to page 4MLTechnical data Type - ML Temperature ranges Nominal temperature range (System) °C 0...70 Operating temperature range (System) #3 °C -10...70 Storage temperature range (System) °C -10...70 Load limits Limit torque, related to Mdn % 325 325 325 225 Breaking torque approx., related to Mdn % 750 750 750 450 Maximum diameter of vehicle steering wheel (when using straight splines) #5 Maximum diameter of vehicle steering wheel (when using bended splines) #5 Minimum diameter of vehicle steering wheel (when using straight splines) #5 Minimum diameter of vehicle steering wheel (when using bended splines)...
Open the catalog to page 5MLTechnical data Type - ML Weight approx. Power supply Max. current consumption in measuring mode A <0.70 Max. current consumption in start-up mode A <2 Nominal power consumption W <17 Load resistance Voltage output kOhm >5 CAN output conversation rate 1/s <1,000.00 Material - Steel Measuring range (related to Mdn) % 120 Compatible evaluation units (TCU) - VETAS3 ©2026, ATESTEO GmbH & Co. KG, This product data sheet was created on 02.05.2026. The information contained in the product data sheet corresponds to the status quo at the time the document was created. ATESTEO continually further develops...
Open the catalog to page 6#5 Vehicle steering wheel Based on customer requests, the measurement systems can optionally be optimized for not listed nominal torque values (intermediate ranges possible). Values of Linearity deviation incl. Hysteresis can only be reached if positive and negative sensitivity values are used. No condensation allowed. Temperature related to housing ground point. The given values are only valid if no other load occurs at the same time. If the loads in sum are 100%, the max. error will be 0.3% of the nominal torque. Limit and break torque are lower if other loads are applied (such as lateral forces)....
Open the catalog to page 7©2026, ATESTEO GmbH & Co. KG, This product data sheet was created on 02.05.2026. The information contained in the product data sheet corresponds to the status quo at the time the document was created. ATESTEO continually further develops its products and reserves the right to make changes to the technical data. ATESTEO does not accept any liability for 8 consequential losses arising from the use of this product data sheet or the information contained therein.
Open the catalog to page 8Would you like to learn more about our products, solutions, and services in the area of measuring systems, vehicle equipment, and actuators? Just call us at +49 (0) 2404 9870 570 or send email to [email protected]. Your personal ATESTEO contact would be pleased to assist you. ATESTEO GmbH & Co. KG Konrad-Zuse-Straße 3 52477 Alsdorf Germany ©2026, ATESTEO GmbH & Co. KG, This product data sheet was created on 02.05.2026. Phone Email The information contained in the product data sheet corresponds to the status quo at the time the document was created. ATESTEO continually further develops its...
Open the catalog to page 921 Pages
21 Pages
21 Pages
23 Pages
23 Pages
23 Pages
23 Pages
23 Pages
68 Pages
7 Pages
116 Pages
11 Pages
30 Pages
26 Pages
17 Pages
69 Pages
13 Pages
20 Pages
124 Pages
21 Pages
124 Pages
20 Pages
17 Pages
124 Pages
20 Pages
7 Pages
7 Pages
18 Pages
21 Pages
27 Pages
21 Pages
124 Pages
35 Pages
27 Pages
51 Pages
27 Pages
11 Pages
20 Pages
132 Pages
41 Pages
132 Pages
132 Pages
21 Pages
21 Pages
21 Pages