1. Catalogs
  2. ATEQ
  3. MASTER LEAKS

MASTER LEAKS

MASTER LEAKS

MASTER LEAKS

Product catalog summary
Master Leaks Specifications and Usage:
  • Master leaks must be used with dry and clean air and should not be used underwater. After use, they should be stored in their protective box.
  • The 'O' ring inside the leak should be checked regularly.
  • Visual checks can be performed by generating bubbles using tubing underwater.
  • The instrument's zero must be checked by blanking the output with a cap.
  • An optional extra leak can be provided for double calibration checks or as a spare when one is sent for recertification.
Operating Instructions:
  • Various pressure levels are provided with corresponding flow rates in cm3/h and cm3/min.
  • Values can vary by ±20%, with true leak rates measured with ±5% accuracy for use between 15°C to 35°C.
  • Special master leaks can be manufactured on request within ±5% of the nominal value.
Master Jets Specifications and Usage:
  • Master jets are used for calibrating ATEQ Flowmeters from the D range and are delivered with a certificate of calibration in a protective box.
  • They are mounted on a tube fitting and should be used with air at 20°C and 1013 hPa.
Operating Instructions:
  • Flow rates are provided for various pressures, with values in dm3/h.
  • Values can vary by ±15%, with true flow measured with ±1.5% accuracy.
  • Special jets can be manufactured within ±5% of the requested value up to 9000 dm3/h.
See more

Catalog excerpts

MASTER LEAKS-1

Master Leaks are used for checking calibration and calibrating ATEQ leak testers from the F and G range. The leaks are delivered with a certificate of calibration in a protective box, mounted on a quick connector. Operating instructions • The leak must be used with dry and clean air • The "O" ring located inside the leak must be checked • The leak must not be used under water, and must be put in its box after use • The Leak can be visually checked by generating bubbles using tubing under water • The zero of the instrument must be checked by blanking the instrument output with cap • Option: an extra Leak can be provided in the same box to allow a double calibration check or a spare calibration office to be used when one is sent to our Laboratory for a recertification Note: the values indicated above are given for information and can vary ± 20%. The true leak rate is precisely measured before delivery with an accuracy of ± 5% of the value for a use between 15°C to 35°C. Special master leaks can be manufactured on request, within ± 5% of the nominal value.

 Open the catalog to page 1
MASTER LEAKS-2

Master jets are used for checking calibration and calibrating ATEQ Flowmeters from the D range. The jets are delivered with acertificate of calibration in a protective box, mounted on a tube fitting. Pressure Operating instructions • Must be used with dry and clean air • Must not be used under water and must be put in their box after use • Must be periodically checked by ATEO's metrology department • Checking the zero of the instrument must be done by blanking the instrument test output with a cap • Option: an extra jet can be provided in the same box to allow a double calibration check or a...