Technical Specifications:
The document details the specifications for the coil series 30x30.5, including various codes (204, 210, 370, 396) with dimensions for Ø A, Ø B, Ø C, and Ø D. It includes a built-in diodes bridge rectifier and offers different connection types such as EN 175301-803 ISO 4400 and Kostal M24x1.

Applications and Power:
These coils are applicable in oil hydraulic, hydraulic, pneumatic, and steam systems. They support supply voltages of 12-24 VDC and 24-230 VAC, with other voltages available upon request. The power specifications include 11 VA for AC absorbed power and 7 W for DC absorbed power.

Environmental and Insulation Details:
The coils operate at 100% ED within a temperature range of -30°C to +50°C. They feature insulation classes “F” (155°C) and “H” (180°C), with copper wire insulation rated at 200°C. The standard protection is IP54, which can be enhanced to IP65, IP67, or IP69K with appropriate gaskets.

Construction Characteristics:
The magnetic circuit is encapsulated with fiber-glass reinforced nylon, and other thermoplastic materials are available on request. Metallic parts are protected against oxidation.

Graphical Data:
A force/stroke graph is provided, indicating performance with a 10% reduced nominal voltage. The graph is indicative and measured in relation to the operators used.

Compliance and Standards:
The document references compliance with IEC 60335-1, IEC 60730-1, IEC 60204-1, and the 2006/95/EC Low Voltage Directive. It advises contacting the technical department for significant values and notes that specifications may change without notice.

Company Overview:
ATAM Group, established in 1992, specializes in components for automatic regulation and industrial automation. The company focuses on technological evolution to meet market demands and maintain competitive performance.
See more

Catalog excerpts

Bobine serie 30x30.5-1

ATAM WINDINGS s.r.l. 20041 Agrate Brianza (MI) Italy Via Archimede, 7 Tel. +39 039 60746.1 Fax +39 039 60746243 [email protected] www.atam.it 30x30.5 Bobine serie 30x30.5 Codici | 204 | 210 | 370 | 396 | *Raddrizzatore ponte diodi incorporato *Included diodes bridge rectifier Cod 204000 204001 204002 204003 204005 Ø A 8 8 7.2 10.2 8.2 Ø B 8 9.1 9.1 10.2 8.2 Ø C 16 16 16 16 16 Ø D 11 11 11 11.5 15 Cod 204006 204007* 204008 204009 Ø A 8.2 10.2 10.2 8.1 Ø B 10.2 10.2 10.2 8.1 Ø C 16 13 13 13 Ø D 11 13 13 15 Cod 210000 210001 210002 210003 Ø A 10.2 8 8 7.2 Ø B 10.2 8 9.1 9.1 Ø C 13 16 16 16 Ø D 13 11 11 11 Cod 210004 210005 204006 Ø A 10.2 8.2 8.1 Ø B 10.2 8.2 8.1 Ø C 16 16 13 Ø D 11.5 15 15 204 Connessione A EN 175301-803 ISO 4400 (DIN 43650) A EN 175301-803 ISO 4400 (DIN 43650) connection 210 Connessione Kostal M24x1 Kostal M24x1 connection Note: Descrizione tecnica Applicazioni Oleodinamica - Idraulica - Pneumatica - Vapore Tensioni di alimentazione 12 - 24 VCC 24 - 110 - 220 - 230 VCA Altre tensioni a richiesta Potenza Potenza assorbita in CA 11 VA Potenza max allo spunto 16 VA Potenza assorbita in CC 7 W Altre potenze a richiesta Funzionamento ED 100% alla potenza e temperature indicate Limiti temperatura ambiente -30°C +50°C Isolamento Classe “F“ 155°C classe “H“ 180°C Isolamento filo di rame Classe “H“ (200°C) Protezione IP54 (IEC 60529) utilizzando l’apposito connettore Montando opportune guarnizioni la protezione può diventare IP65. Sono realizzabili soluzioni IP67 e IP69K Colore standard Nero Caratteristiche costruttive Circuito magnetico rivestito in nylon caricato fibra di vetro Altri materiali termoplastici disponibili su richiesta Particolari metallici protetti contro l’ossidazione Technical description Applications Oil Hydraulic - Hydraulic - Pneumatic - Steam Supply voltages 12 - 24 VDC 24 - 110 - 220 - 230 VAC Other voltages on request Power AC absorbed power 11 VA Maximum inrush power 16 VA DC absorbed power 7 W Other powers on request Operation ED 100% at the showed power and temperatures Environment temperature limits -30°C +50°C Insulation Class “F“ 155°C class “H“ 180°C Copper wire insulation Class “H“ wire (200°C) Protection IP54 (IEC 60529) with the appropriate connector With appropriate gaskets the protection becomes IP65. IP67 and IP69K solutions are feasible Standard colour Black Construction characteristics Magnetic circuit encapsulated with fibre-glass reinforced nylon Other thermoplastic materials on request Metallic parts protected against oxidation release 06/2009

 Open the catalog to page 1
Bobine serie 30x30.5-2

ATAM WINDINGS s.r.l. 20041 Agrate Brianza (MI) Italy Via Archimede, 7 Tel. +39 039 60746.1 Fax +39 039 60746243 [email protected] www.atam.it 30x30.5 Coil series 30x30.5 Codes | 204 | 210 | 370 | 396 | Cod 370000 370001 370002 370003 Ø A 10.2 8 8 7.2 Ø B 10.2 8 9.1 9.1 Ø C 13 16 16 16 Ø D 13 11 11 11 Cod 370004 370005 370006 Ø A 10.2 8.2 8.1 Ø B 10.2 8.2 8.1 Ø C 16 16 13 Ø D 11.5 15 15 Cod 396000 Ø A 10.2 Ø B 10.2 Ø C 13 Ø D 13 370 Connessione cavetti Lead wires connection 396 Connessione AMP Junior AMP Junior connection Lunghezza cavetti standard 200-600 mm Standard lead wires length 200-600 mm 12.5...

 Open the catalog to page 2
Bobine serie 30x30.5-3

ATAM WINDINGS s.r.l. 20041 Agrate Brianza (MI) Italy Via Archimede, 7 Tel. +39 039 60746.1 Fax +39 039 60746243 [email protected] www.atam.it Norme di riferimento: IEC 60335-1 Sicurezza degli apparecchi elettrici d'uso domestico IEC 60730-1 Dispositivi elettrici automatici di comando per uso domestico e similare IEC 60204-1 Sicurezza del macchinario. Equipaggiamento elettrico del macchinario 2006/95/EC Direttiva bassa tensione I disegni e i dati tecnici contenuti nelle schede sono stati verificati e ritenuti corretti, tuttavia non viene assunta alcuna responsabilità in merito agli stessi. Per i valori...

 Open the catalog to page 3
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.