DC Fuse Holeder EDFH series Fuse 1000V Leading Manufacturer Protects Solar Power Safety Rev1.0
Open the catalog to page 1EDFH series DC Fuse 1 OOOV Product Application EDFH series fuse holder is made of refractory material, and meets the standard of IEC 60947-3. The maximum rated voltage is 1 000V and the maximum current is 30A. As a short circuit and over-current protector, it is widely used in the high and low voltage distribution system, control system, and electrical equipments, like distribution box and inverter. Product Benefits • • • • DIN35 Rail Installation, Easy to Install Adjustable terminal block, Wiring firm Fire-retardant shell, high temperature resistance Flexible installation, Easy to replace...
Open the catalog to page 2DC FUSE HOLEDER EDFH series Fuse 1 OOOV Technical Data PV DC EDFH Fuse Holder Pole Electrical Characteristics Rated Working Voltage Rated Current Breaking Capacity Max PowerDissipation Control and Indication Connection and lnstallationWire Terminal Screws Torque Installation Environment Fuse Size Operating Temperature Range Mounting PollutionDegree Relative Humidity Installation Class Weight Replacement Fuse
Open the catalog to page 3DC FUSE HOLEDER EDFH series Fuse 1 OOOV Product Application EDFH series fuse holder is made of refractory material, and meets the standard of IEC 60947-3. The maximum rated voltage is 1 000V and the maximum current is 30A. As a short circuit and over-current protector, it is widely used in the high and low voltage distribution system, control system, and electrical equipments, like distribution box and inverter. Product Benefits • • • • Din35 Rail Installation, Easy to Install Adjustable terminal block, Wiring firm Fire-retardant shell, high temperature resistance Flexible installation,...
Open the catalog to page 4DC FUSE HOLEDER EDFH series Fuse 1 OOOV Technical Data PV DC EDFH Fuse Holder Pole According to Electrical Characteristics Rated Working Voltage Rated Current Breaking Capacity Max PowerDissipation Control and Indication Operating State/Fault Indication Connection and lnstallationWire Terminal Screws Torque Degree of Protection Indicator Light OFF/Indicator Light ON 1.5mm'- 10mm' M3.5 0.8-1.2N-m IP20 Installation Environment Fuse Size Operating Temperature Range Mounting PollutionDegree Relative Humidity Installation Class Weight Replacement Fuse
Open the catalog to page 5Product Benefits • • • • Amps:1-32A Volts: 1 000VDC Breaking Capacity:30kA@1000DC Compact design.Low power loss.Excellent DC performance Low arc voltage and low energy let-through(l2t) Product storage temperature: -40°C-120°C. At 40°C, the relative humidity is not more than 70%, below 30°C, not more than 80%, below 20°C, not more than 90% • Packaging and storage temperature: -40°C-80°C. The relative humidity is not more than 90%, and there is no condensation Altitude • 2000 - 4500m • Higher altitude mainly leads to insulation deterioration, heat dissipation condition deterioration and air...
Open the catalog to page 6DC FUSE HOLEDER 1 0x38mm Photovoltaic Fuses Electrical Characteristics Designed to: UL248-19/IEC60269-6 GB/T13539-6 Energy Integrals l't Clearing at 1000V
Open the catalog to page 7ASwich I Safety Is On 1 0x38mm Photovoltaic Fuses Prospective Current In Amps RMS 1A 0.01 Virtual Pre-Arcing Time In Seconds Operating conditions Ambient air temperature • When the fuse exceeds the service conditions, some parameters may need to be corrected, and our company should be consulted. • It is recommended that the current value of long-term through current shall allowable service conditions: -40 C-80 C. ° • When the fuse works above 40 C, the rated current needs additional correction, and the correction factor is - KT • Parameters of air temperature change: when working below -5...
Open the catalog to page 8DC FUSE HOLEDER EDFH series Fuse 1500V Product Application This series of fuse is suitable for solar photovoltaic power generation system,rated voltage up to 1 S00V,rated current to S0A,connected with photovoltaic panels and batteries ,to charge variable flow system for short circuit breaking protection in photovoltaic station and photovoltaic power generation system.the rated breaking capacity is 20KA,products confirms to UL248-19 IEC 60269-6 Product Benefits • Ambient Temperature:-40°C- + 90°C. • Equipment installation height less than 2000m (if you want use exceedng this height,pls tell...
Open the catalog to page 9ASwich I Safety Is On Electrical Characteristics Installation Environment Operating Temperature Range Material Torque Standard Rated Working Voltage Rated Current Breaking Capacity Wire Range Fuse Specifications Rated Working Voltage Rated Current Breaking Capacity Class Time Constant Testing Method GPV The appointed time and current of Fuse Appointed Current GPV Fuse Appointed current rated Time Inf If ln:;;;63A 63A400A 4
Open the catalog to page 10DC FUSE HOLEDER EDFH series Fuse 1500V Electrical Characteristics 1 2 3 Replacement Fuse
Open the catalog to page 11All Aswich Electrical Co. catalogs and technical brochures
-
Load-breaking switch EHD
4 Pages
-
load-breaking switch
4 Pages
-
DC Isolation Switch
11 Pages
-
IEC isolator switch EDS1DC/S32
11 Pages
-
Rectangular enclosure EDS1DB/N32
11 Pages
-
Voltage circuit breaker
3 Pages
-
DC Fuse Holeder
11 Pages
-
Rectangular enclosure EDS6EL
3 Pages
-
AC circuit breaker ESM2-63
1 Pages
-
AC circuit breaker ESRO1-50
1 Pages
-
EDS6EL
3 Pages
-
EDFH series Fuse 1000V
11 Pages
-
AC isolator switch EAS50/N
4 Pages
-
AC MINIATURE
7 Pages
-
AC isolator switch EAS50/NS
4 Pages
-
Isolator switch JHAS80-PM
26 Pages
-
AC isolator switch JHAC69
5 Pages
-
AC circuit breaker ESRO2-40
1 Pages
-
DC Surge Protector
7 Pages
-
Waterproof switch ERS-10 Series
16 Pages
-
IP66 switch ERS-6/8 Series
16 Pages
-
DC switch ERP-80PYS
4 Pages
-
Rectangular enclosure ECB Series
24 Pages
-
EAS series
16 Pages
-
EDS7 Series
6 Pages
-
AC charging station EEVC
8 Pages
-
Voltage circuit breaker
13 Pages
-
EDS1PM Series DC Isolator
7 Pages
-
DC Isolator EDS7HM
4 Pages
-
INDUSTRIAL CONTROL
155 Pages
-
EV CHARGER
5 Pages
-
ERS-2/4 Series
15 Pages