Readout transmitter ZE3075
2Pages

{{requestButtons}}

Catalog excerpts

Readout transmitter ZE3075 - 1

Technical data Measuring value • Flow Measuring principle • Reed chain • Trigger element Magnetic float CE sign • DIN EN 61326-1, DIN EN 55022/B Type of protection • with IP 65 plug Voltage supply • Uin = 18 ... 30 V DC Connection cable • Cable outside diameter: 6 ... 8mm • Nominal cross-section: max. 0.75 mm2 Housing material • ABS Output signal • 2-wire technology • 4 ... 20 mA (flow) • Output can be calibrated/set Measuring length: • 114 mm Product description The flow data sensor ZE 3075 is used as a transducer for the ASV flowmeter DFM 165 to DFM 200 and fitted to the dovetail guide. The 4 ... 20mA output signal is in proportion to the height of the magnetic float. Function description The flow data sensor ZE 3075 emits a 4 ... 20mA signal generated by the height of the float in the flowmeter (DFM). The unit comprises a reed chain, the respective evaluation and implementation. The float of the flowmeters is fitted with a permanent magnet. The float travels along the reed chain by the flow of the medium. The individual contacts of the reed chain are actuated in accordance with the height of the float. The measured values are emitted as a 2-wire current signal 4 ... 20mA. This signal can be directly further processed. Actuation Actuation is through the magnet in the float of the ASV flowmeter. Mounting direction vertical installation, ASV logo on top. Connection cable The unit is connected with a commercially available unshielded cable. Where electro-magnetic interference above the EN 61326 test values for industrial areas is to be expected, we recommend the use of a shielded cable. Data sheet no.: 330618 - 2010/09/17 All rights for technical modifications withheld

Open the catalog to page 1
Readout transmitter ZE3075 - 2

Ambient temperature • -20 ... 70 °C Process temperature • 0 ... 70 °C Ambient pressure • atmospheric (0.8 ... 1.1 bar Relative humidity • 20 ... 85 % Components 1. Notches for the measuring range 2. Potentiometer for the upper limit value of the output signal 3. Potentiometer for the lower limit value of the output signal 4. Plug connector Ident number Installation spacing When fitting several DFMs with ZE 3000 in parallel, observe the minimum spacings Flange connector Circuit diagram Technische Anderungen vorbehalten All rights for technical modifications withheld Data sheet no.: 330618...

Open the catalog to page 2

All ASV Stuebbe GmbH & Co. KG catalogs and technical brochures

  1. Pumps

    17 Pages