Astronics Test Systems Inc. Racal Instruments™ Register-Based Prototyping Modules The Racal Instruments™ 7064R Series of C-sized, register-based prototyping modules simplify the engineer’s task of developing custom VXIbus products. The built-in VXIbus interface and complete documentation package, including extensive application notes, reduces prototype design time. The 7064R supports 16-bit data transfer rates up to 4MB/sec and 32-bit data transfer rates up to 8 MB/sec. All seven VXIbus power supply lines are available to the user and are fused, reducing the risk of damage to the backplane. The module also provides EMI power filtering, which is required by the VXIbus specification. The module is offered in two different slot widths to accommodate various packaging requirements. Key Features • Register-based interface supports high-speed data transfer • Supports 8, 16, and 32-bit data bus with A16, A24 or A32 addressing • 80 in2 of prototyping space on 0.1 inch grid • 3 (1X4), 40 MHz, 2A, 1-wire multiplexers in the development area • Fused and filtered VXIbus supply voltages • Available in single and double slot widths Product Information Functional Description The Interface Section of the 7064R consists of VXIbus backplane interface circuitry, DIP switches to select the logical address and IRQ interrupt priority, and jumper pads for setting the ID and Device Type Registers. The VXIbus signals are accessed via P11, a 96-hole pattern that will accommodate a standard DIN connector, and via E-points located within the interface section. The Local Bus is accessed via P5/P6 and TTL Trigger lines are accessed via P7 as shown. The Prototyping section makes available over 80 square inches of user defined development area. It consists of a universal grid on 0.1-inch centers. Seventy-seven pairs of +5 VDC/GND pads are distributed evenly within the development area. Packaging The module is available in one, two, and three slot packages. The multiple slot widths are offered to provide additional space on both sides of the prototyping board to accommodate wire-wrap pins or for mounting parts requiring more headroom than is available in a single slot package. Refer to the specification section for clearance dimensions. The front panel is removable to facilitate through-hole machining if external connections to the module are needed. 949.859.8999; 800.722.2528; atssales@astronics.com; www.astronicstestsystems.com Copyright © 2014 Astronics Test Systems Inc. The front panel also provides ACCESS and FAIL LED indicators for convenient monitoring. A “bare board” version of the prototyping module is also available. It comes standard with P1/P2 connectors, all seven fused and filtered VXI supply voltages, and 80 sq. in. of breadboard area. You have access to a limited number of VXI backplane signals via E-points. The board and enclosure must be ordered separately. When to Use the Register-Based 7064R The register-based 7064R should be considered when maximum throughput across the VXIbus interface is desired. Typical applications may involve real-time processing or high-speed data acquisition. If throughput is not a concern and a simple user interface is desirable, consider the 7064M Message-based
Open the catalog to page 1Astronics Test Systems Inc. Maximum User Current Temperature • Operating: 0º C to +55º C • Storage: -40º C to +71º C Note: The Astronics Test Systems policy is one of continuous development and improvement. Consequently, the equipment may vary in detail from the description and specifications in this publication. Functional Performance Enclosure Style • VXI C-size Prototyping Enclosure Altitude • Operating: 10,000 ft • Storage: 15,000 ft Modes of Operation • VXI Register-Based Servant • Interrupter Prototyping Area Clearances Type Data Transfer Bus • D32, D16, D08 (EO) Support Data Transfer...
Open the catalog to page 2All Astronics Test Systems catalogs and technical brochures
-
1264c
2 Pages
-
4024h
1 Pages
-
Option 01T
2 Pages
-
1256L
2 Pages
-
1260-101
2 Pages
-
1260-100
2 Pages
-
1260-152/172
3 Pages
-
1260-120
3 Pages
-
1260-120
3 Pages
-
1260-150
3 Pages
-
1260-136B/C/D
2 Pages
-
1260-138A
3 Pages
-
1260-134
2 Pages
-
1260-167AH/BH
2 Pages
-
1260-164AH/BH
2 Pages
-
1260-162AH/BH
2 Pages
-
1260-145A-G
3 Pages
-
1260-116
2 Pages
-
1260-117/117A
3 Pages
-
1260-118/118A
3 Pages
-
3172
6 Pages
-
3152B
6 Pages
-
3151B
5 Pages
-
3164_2_0
3 Pages
-
3156c
5 Pages
-
313A
1 Pages
-
6084A-104-DMM
5 Pages
-
6084-2105
2 Pages
-
PXIe-1803
4 Pages
-
PXIe-6943
6 Pages
-
VX407C
2 Pages
-
VX405C
2 Pages
-
203PC-1, 2
3 Pages
-
1257A
10 Pages
-
1263HPf
2 Pages
-
T940
8 Pages
-
COTS Product Guide December, 2011
339 Pages
-
1261B-S-2378
2 Pages
-
1261B linear
3 Pages
-
1261B
5 Pages
-
1260-x153
2 Pages
-
1260-x121
2 Pages
-
1260-1114
2 Pages
-
1260-700
2 Pages
-
1260-155
2 Pages
-
1260-115
2 Pages
-
1260-114
3 Pages
-
1260-100
2 Pages
-
1260-88
2 Pages
-
1260-75
2 Pages
-
1260-58
2 Pages
-
1260-54
2 Pages
-
1260-51
2 Pages
-
1260-16
2 Pages
-
1260-14
2 Pages
-
1260-00C
3 Pages
-
1255A
2 Pages