Astronics Test Systems Inc. Racal Instruments™ 6084A-104-DMM 1 GHz Digitizer and 7.5 Digit Digital Multimeter The Racal Instruments™ 6084A-104-DMM Digitizer/DMM increases test system performance and density by packaging a 7.5 digit Digital Multimeter (DMM) together with a 10-bit, 1 GHz Digitizer into a single VXI slot. Designed to exceed the requirements for Joint Services Military ATE systems, the 6084A-104-DMM is ideal for solving obsolescence, reducing footprint, and enhancing the performance of new or pre-existing ATE systems. The instrument may be configured as a Digitizer/DMM or as a single instrument (Digitizer or DMM). • Replaces the Wavetek 1362 DMM, Analogic DBS series and Agilent VXI digitizers • Digitizer with 4 inputs, 10-bits, 1 GHz, up to 4 GS/s and ranges up to 500 V • DMM with 7.5 Digits for DC volts, current and Q with AC volts up to 1 MHz • IVI-COM drivers and soft front panels provided • More dynamic range (by 20 dB for dmm and 12 dB for digitizer) for better legacy range mapping Product Information High-Precision 7.5 Digit DMM The 6084A-104-DMM high-precision DMM with 7.5 digit resolution is designed to meet the Joint Services requirements for Military ATE systems. The high-precision and high-accuracy ensures that the DMM will meet the requirements for legacy ATE systems and future TPS development. Measurements include DC and AC volts, DC and AC current, two and four wire resistance measurements, frequency and period. High-Performance Digitizer The 6084A-104-DMM features a high-performance 10-bit 4 GS/s digitizer designed to meet the Joint Services requirements for Military ATE systems. The high-performance capability ensures that the digitizer will meet the requirements for legacy ATE systems and future TPS development. The digitizer features four channels (two active at one time). The high-speed digitizer features a bandwidth of 1 GHz in 50 Q mode. features ±20 million counts compared to ±1 to 2 million typical that is found in older designs for an additional 20 dB of headroom. The 6084A-104-DMM digitizer features 10-bits of resolution, which is 12 dB more than what is found in older, 8-bit designs. This allows flexibility when mapping a physical DMM or digitizer range to a legacy range that was different. Legacy Range Matching The 6084A-104-DMM DMM range values and functionality are identical to those of the obsolete Wavetek 1362 DMM for the DCV, ACV (DC and AC coupled), and resistance functions. Although the DMM can handle the measurement in a mapped range without losing any resolution versus legacy models, its ranges are mapped to those of the legacy Wavetek 1362 for strict range compliance. The resistance mode current sources and AC voltage frequency range also match those of the Wavetek 1362. More Dynamic Range The 6084A-104-DMM digitizer and DMM feature more dynamic range than was available in older-generation test equipment. The 6084A-104-DMM DMM 949.859.8999; 800.722.2528; [email protected]; www.astronicstestsystems.com Copyright © 2014 Astronics Test Systems Inc.
Open the catalog to page 1Astronics Test Systems Inc. Racal Instruments™ 6084A-104-DMM Specifications Note: The Astronics Test Systems policy is one of continuous development and improvement. Consequently, the equipment may vary in detail from the description and specifications in this publication. Input Characteristics Bandwidth (-3 dB) • 50 Q: DC to 1 GHz (typ) <5 V • 50 Q: DC to 300 MHz (typ) <20 V • 1 MQ: DC to 300 MHz (typ) <50 V • 1 MQ: DC to 1 MHz (typ. <500 V Maximum Input Voltage • ±10 V/7 V with 50 Q rms • ±300 V DC with 1 MQ Full Scale (FS) • 50 Q and 1 MQ: 50 mV, 100 mV, 200 mV, 500 mV, 1 V, 2 V, 5 V, 20 V •...
Open the catalog to page 2Astronics Test Systems Inc. Racal Instruments™ 6084A-104-DMM 6084A measurement accuracy1 ± (% of reading + % of range) 949.859.8999; 800.722.2528; [email protected]; www.astronicstestsystems.com Copyright © 2014 Astronics Test Systems Inc.
Open the catalog to page 3Astronics Test Systems Inc. Racal Instruments™ 6084A-104-DMM 6084A measurement accuracy1 ± (% of reading + % of range) 1 To obtain the specified accuracies, allow 30 minutes of warm-up. 2 Accuracies are with aperture set to >0.5 s, and within one hour from self-calibration. 3 Accuracies are with aperture set to >0.96 s, and within one hour from self-calibration (relative control). 4 Between 5 mV and 10 mV, add 100 pV of additional error. 5 Signal is limited to 8x106 Volt-Hz product. For example, the largest frequency input at 250 V is 32 kHz. 6 For a crest factor >3, add an additional ±0.1% error....
Open the catalog to page 4Astronics Test Systems Inc. Racal Instruments™ 6084A-104-DMM Specifications continued DMM Trigger Input • Connector: DE-9M • Level: TTL DMM Sync Output • Connector: DE-9M • Level: TTL DMM Voltage/Q • Connectors: Mini Banana (Hi/Lo) • Impedance: 10 MO or >10 GO DMM Current/Sense • Connectors: Mini Banana • Protection: 3 A fuse Software Software Compliance • DMM: IVI-DMM Class Compliant Driver • Digitizer: IVI Custom Specific Instrument Driver Drivers • IVI-COM Environmental Temperature • Operating: 0° C to 40° C • Storage: -40° C to 71° C Relative Humidity • 5% to 80% RH non-condensing <37° C Altitude •...
Open the catalog to page 52 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
3 Pages
3 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
3 Pages
3 Pages
6 Pages
6 Pages
5 Pages
3 Pages
5 Pages
1 Page
2 Pages
4 Pages
6 Pages
2 Pages
2 Pages
3 Pages
10 Pages
2 Pages
8 Pages
339 Pages
2 Pages
3 Pages
5 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages