203PC-1, 2 - 1

Astronics Test Systems Inc. The Trig-Tek™ 203PC-1, -2 charge amplifiers operate with high temperature accelerometers where pyroelectric effects may be encountered. Key Features • pC or mV mode • Accel or Vel input • High-Pass and Low-Pass Filters • Overload detection • Six Full Scale (FS) ranges • DVM indicator • 0.1 to 199.9 input sensitivity • AA, AV, AD, VV, VD • 115 or 230 Vrms power Product Information The Trig-Tek™ 203PC-1 and 203PC-2 cover the frequency range from 3 Hz to 40,000 Hz. They double-integrate the 10 g acceleration output signal to provide velocity and displacement outputs. A four-position thumb-wheel sensitivity control in conjunction with a three-position toggle switch accommodates pickups having sensitivities from 0.100 to 199.9 pC/g, mV/g, or mV/ips. A “Mode” switch selects “pC/g” (“AA,” “AV,” or “AD”), “mV/g” (“AA,” “AV,” or “AD”), or “Vel” (VV or VD). The DC output switch selects “X1” or “X10” for g’s, ips, or MILs at the “DC Output.” An external “Cal” signal can be selected by a front panel switch or by the “Cal” control input (rear panel). A Low-Pass Filter has 100 Hz to 19.9 kHz cutoff frequencies in 100 Hz steps, and a High-Pass filter has 1 to 999 Hz cutoff frequencies in 1 Hz steps. A digital front-panel meter displays selectable Full Scale (FS) levels of “10,” “20,” “50,” “100,” “200,” or “500” g’s Pk or “1,” “2,” “5,” “10,” “20,” or “50” ips or MILS Pk. The 203PC is packaged as a plug-in module. Available are a single-module chassis and a six-module chassis. 949.859.8999; 800.722.2528; atssales@astronics.com; www.astronicstestsystems.com Copyright © 2014 Astronics Test Systems Inc. When “mV/ips” is selected, the amplifier will operate with ICP-type velocity pickup with the “Curr-On” or with a standard velocity pickup with the “Curr-Off.” A “DC Output” switch permits selection of either “X1,” “X10,” “10 mV/g,” or “100 mV/ips” or MIL at the “DC Output.” An “External Cal” signal can be selected by the front panel “Mode”/”Units” switch or by the “Cal” control input (rear panel). An internal switch has three positions: “A,” “V,” and “Out.” In the “A” position, it places the Low-Pass Filter in the acceleration before the velocity integrator path. In the “V” position, it places the filter behind the velocity integrator path. In the “Out” position, there is no filter. A second internal switch marked “V,” “D,” and “DC” will place the High-Pass Filter at the velocity output for “V”, at the displacement output for “D”, and in the DC path in the “DC” position. The unit has overload circuits to alert if FS Pk levels are exceeded.

Open the catalog to page 1
203PC-1, 2 - 2

Astronics Test Systems Inc. Specifications Note: The Astronics Test Systems policy is one of continuous development and improvement. Consequently, the equipment may vary in detail from the description and specifications in this publication. Noise • 0.05 pC maximum with 1.0 pC/g sensitivity. Noise increased 0.006 g/1000 pF of additional capacity at the input Charge Sensitivity • 0.1 to 199.9 pC/g or mV/g with three selectable range: “X.1,” “X1,” and “X10” Velocity Output Sensitivity • 10 or 100 mV/Pk g; or 0.1 or 1 V/Pk ips or MILS as selected by the “Mode”/”Units” switch and the “DC Output”...

Open the catalog to page 2
203PC-1, 2 - 3

Astronics Test Systems Inc. Specifications continued Variable Pre & Post Low-Pass Filter Adj (A5 – W30A)* • Sets variable frequency cutoffs (R1 on A5-W30A) Mode/Units switch • Selects input modes “pC/g,” “mV/g,” “mV/ips” or “Cal”; and the meter and DC input units “AA,” “AV,” “AD,” “VV,” or “VD” Multiplier Input Range Switch • Selects “X.1,” “X1,” or “X10” multiplier for 1.00 to 19.99 pC/g, mV/g, or mV/ips sensors Sensitivity Switch • Selects charge sensitivity from 1.00 to 19.99 for each range, selected by the multiplier switch FS Switch • The FS switch has six positions, which work in...

Open the catalog to page 3

All Astronics Test Systems catalogs and technical brochures

  1. 1264c

    2 Pages

  2. 4024h

    1 Pages

  3. Option 01T

    2 Pages

  4. 1256L

    2 Pages

  5. 1260-101

    2 Pages

  6. 1260-100

    2 Pages

  7. 1260-152/172

    3 Pages

  8. 1260-120

    3 Pages

  9. 1260-120

    3 Pages

  10. 1260-150

    3 Pages

  11. 1260-138A

    3 Pages

  12. 1260-134

    2 Pages

  13. 1260-145A-G

    3 Pages

  14. 1260-116

    2 Pages

  15. 3172

    6 Pages

  16. 3152B

    6 Pages

  17. 3151B

    5 Pages

  18. 3164_2_0

    3 Pages

  19. 3156c

    5 Pages

  20. 313A

    1 Pages

  21. 6084-2105

    2 Pages

  22. PXIe-1803

    4 Pages

  23. PXIe-6943

    6 Pages

  24. VX407C

    2 Pages

  25. VX405C

    2 Pages

  26. 1257A

    10 Pages

  27. 1263HPf

    2 Pages

  28. T940

    8 Pages

  29. 1261B-S-2378

    2 Pages

  30. 1261B linear

    3 Pages

  31. 1261B

    5 Pages

  32. 1260-x153

    2 Pages

  33. 1260-x121

    2 Pages

  34. 1260-1114

    2 Pages

  35. 1260-700

    2 Pages

  36. 1260-155

    2 Pages

  37. 1260-115

    2 Pages

  38. 1260-114

    3 Pages

  39. 1260-100

    2 Pages

  40. 1260-88

    2 Pages

  41. 1260-75

    2 Pages

  42. 1260-58

    2 Pages

  43. 1260-54

    2 Pages

  44. 1260-51

    2 Pages

  45. 1260-16

    2 Pages

  46. 1260-14

    2 Pages

  47. 1260-00C

    3 Pages

  48. 1255A

    2 Pages