video corpo

1260-136B/C/D

1260-136B/C/D

1260-136B/C/D

Product catalog summary
Overview: The Racal Instruments™ 1260-136 series are high-voltage relay multiplexers designed for the Adapt-a-Switch™ platform, suitable for hipot and cable breakdown testing, and switching source-measure units in ATE systems. These plug-ins offer high density and software-configurable switch modes for simplified test development.
Key Features:
  • High density configuration up to 1x42 on a single plug-in.
  • Three relay versions available: 1260-136B (500 V, Reed Relay), 1260-136C (1 kV, Reed Relay), and 1260-136D (500 V, Mercury Wetted Reed Relay).
  • Software configurable switch modes and plug-in design for rapid expansion and replacement.
Product Configurations: The plug-ins can be configured as a single 1x21 two-wire multiplexer, a single 1x42 one-wire multiplexer, or two 1x21 one-wire multiplexers. They support both distribution and scanner applications with features like make-before-break or break-before-make.
Specifications:
  • Maximum Switching Voltage: 500 VDC/500 VACpk-pk for B and D, 1000 VDC/1000 VACpk-pk for C.
  • Maximum Switching Current: 0.5 A for B, 1 A for C and D.
  • Maximum Switching Power: 10 W for B, 25 W for C, 50 W for D.
  • Operating Temperature: 0° C to 55° C; Storage Temperature: -40° C to 75° C.
  • Relative Humidity: 85% ±5%, non-condensing at <30° C.
  • Altitude: Operating up to 10,000 ft, Non-Operating up to 15,000 ft.
Environmental and Safety Standards: The product complies with European electrical safety standards and has passed rigorous testing for RF emissions and immunity to electromagnetic disturbances.
Ordering Information: The document provides specific part numbers for ordering different versions of the plug-ins and accessories like the Racal Instruments™ Option 01T Smart Card Module.
Mechanical and Operational Details:
  • Weight: 9 oz (0.26 kg).
  • Dimensions: 4.5” H x 0.75” W x 9.5” D.
  • Relay Operate Time: 0.5 ms (typical).
  • Contact Bounce Time: 0.25 ms for B and C, none for D.
  • Rated Switch Operations: Mechanical up to 1,000,000,000 operations for D, Electrical up to 50,000,000 operations at full rated load for D.
Reliability: MTBF is 87,796 hours according to MIL-HDBK-217FN2 and 229,159 hours according to Telcordia (Bellcore) standards. MTTR is less than 5 minutes.
See more

Catalog excerpts

1260-136B/C/D-1

Astronics Test Systems Inc. Racal Instruments™ 1260-136B/C/D High-Voltage Multiplexer Plug-In The Racal Instruments™ 1260-136 series plug-ins are high-voltage relay multiplexers for the Adapt-a-Switch™ platform. These quickly and easily plug into the front of an Adapt-a-Switch™ Carrier 1260-100. Key Features • Ideal for hipot and cable breakdown testing • Ideal for switching source-measure units and high-voltage power supplies in an ATE system • High density - up to 1x42 on a single plug-in • Software configurable switch modes simplify test development • Three relay versions available to support a wide range of requirements • Plug-in design for rapid expansion and replacement Product Information Each 1260-136 series plug-in can be configured via standard program control into any of the following configurations: • single 1x21 two-wire multiplexer • single 1x42 one-wire multiplexer • two 1x21 one-wire multiplexer 1260-136 plug-ins can be used for distri bution applications in which any combination of relays per multiplexer are closed at a time, or in classical scanner applications in which only one relay per multiplexer may be closed. When used as a scanner, the 1260 series “exclude” feature will automatically open the last connection when a new connection is programmed. This reduces the number of commands sent to the switch, thereby reducing test time. Make-before-break or break-before-make can also be programmed. Three different versions of this plug-in are available to support a range of high voltage switching requirements. Each version uses a different high voltage relay. Basic “hot-switching” specifications of these plug-ins are as follows: • 1260-136B, 500 V, Reed Relay • 1260-136C, 1 kV, Reed Relay • 1260-136D, 500 V, Mercury Wetted Reed Relay The 1260-136D must be oriented vertically to operate properly. This is the normal position for installations using a 13-slot VXI chassis and Adapt-a-Switch™ carrier. The 1260-136B and C versions are not position sensitive; they will operate properly in installations oriented in any direction. A Racal Instruments™ Option 01T is required to communicate with 1260 series modules, and provides message-based operation for ease of use and register-based operation for maximum speed. The Option 01T provides a single point of software control for the switching system with advanced features such as include, exclude, scan, relay monitoring, user defined path names, and reset states. The 1260 series line includes VXIplug&play support for frameworks based on Microsoft Win32® application programming interface, including drivers for LabWindows™/CVI and LabVIEW™. 949.859.8999; 800.722.2528; [email protected]; www.astronicstestsystems.com Copyright © 2014 Astr

 Open the catalog to page 1
1260-136B/C/D-2

Astronics Test Systems Inc. Specifications Note: The Astronics Test Systems policy is one of continuous development and improvement. Consequently, the equipment may vary in detail from the description and specifications in this publication. Input Maximum Switching Voltage • B,D: 500 VDC, 500 VACpk-pk • C: 1000 VDC, 1000 VACpk-pk Maximum Switching Current • B: 0.5 ADC or AAC • C,D: 1 ADC or AAC Maximum Switching Power • B: 10 W, 10 VA • C: 25 W, 25 VA • D: 50 W, 50 VA Environmental Temperature • Operating: 0° C to 55° C • Storage: 40° C to 75° C Relative Humidity • 85% ±5%, non-condensing at <30°...

 Open the catalog to page 2

All Astronics Test Systems catalogs and technical brochures

  1. 1264c

    2  Pages

  2. 4024h

    1  Page

  3. Option 01T

    2  Pages

  4. 1256L

    2  Pages

  5. 1260-101

    2  Pages

  6. 1260-100

    2  Pages

  7. 1260-152/172

    3  Pages

  8. 1260-120

    3  Pages

  9. 1260-150

    3  Pages

  10. 1260-138A

    3  Pages

  11. 1260-134

    2  Pages

  12. 1260-167AH/BH

    2  Pages

  13. 1260-164AH/BH

    2  Pages

  14. 1260-162AH/BH

    2  Pages

  15. 1260-145A-G

    3  Pages

  16. 1260-116

    2  Pages

  17. 1260-117/117A

    3  Pages

  18. 1260-118/118A

    3  Pages

  19. 3172

    6  Pages

  20. 3152B

    6  Pages

  21. 3151B

    5  Pages

  22. 3164_2_0

    3  Pages

  23. 3156c

    5  Pages

  24. 313A

    1  Page

  25. 6084A-104-DMM

    5  Pages

  26. 6084-2105

    2  Pages

  27. PXIe-1803

    4  Pages

  28. PXIe-6943

    6  Pages

  29. VX407C

    2  Pages

  30. VX405C

    2  Pages

  31. 203PC-1, 2

    3  Pages

  32. 1257A

    10  Pages

  33. 1263HPf

    2  Pages

  34. T940

    8  Pages

  35. 1261B-S-2378

    2  Pages

  36. 1261B linear

    3  Pages

  37. 1261B

    5  Pages

  38. 1260-x153

    2  Pages

  39. 1260-x121

    2  Pages

  40. 1260-1114

    2  Pages

  41. 1260-700

    2  Pages

  42. 1260-155

    2  Pages

  43. 1260-115

    2  Pages

  44. 1260-114

    3  Pages

  45. 1260-88

    2  Pages

  46. 1260-75

    2  Pages

  47. 1260-58

    2  Pages

  48. 1260-54

    2  Pages

  49. 1260-51

    2  Pages

  50. 1260-16

    2  Pages

  51. 1260-14

    2  Pages

  52. 1260-00C

    3  Pages

  53. 1255A

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.