1. Catalogs
  2. AST - Applied Sensing Technologies
  3. MODEL1019_Datasheet-Feb-2021

MODEL1019_Datasheet-Feb-2021
1 /1Page

MODEL1019_Datasheet-Feb-2021

MODEL1019_Datasheet-Feb-2021
1 /1Page

Catalog excerpts

MODEL1019_Datasheet-Feb-2021-1

APPLIED SENSING TECHNOLOGIES Advanced Sensor Technology Proprietary Electrolyte Formulation and Anode Meterial Electro-etched Smooth Cathode Recovery From Air to 10 PPM in under 40 Minutes Extended Operating Temperature Range -10°C (-4°F) Z-Series sensor Compatibility with 0-100% CO2 Fast Sensor Response, no Routine Sensor Maintenance Needed MODEL 1019 PPM Oxygen Analyzer Rack and Panel Mount Configurations User Selectable Range From 1 PPM to 25% Output Locking on Selected Range Isolated 4-20mA and 0-1 VDC Signal Output Standard Fine Tuned Temperature Compensation Barometric Pressure Compensation Sensor Fail Alarm 100-240 VAC Universal AC/DC 5V Power Adoptor Can be Powered via USB Analyzer Technical Specifications * Measurement Range: User selectable from 0-5 PPM - 21% • Display: Bright 2-Line LED • Output Lock: 4-20 mA locked on user selectable range. • Accuracy: < 2% of FS at constant operating conditions • Linearity: +/-1% after calibration • Temperature Compensation: Fine tune on low PPM range for enhanced stability • Barometric Pressure Compensation: Optional • Calibration Method: Certified Span Gas or air, Recommended Calibration interval 30 days • Alarms: Two user configurable O2 alarms with option for latching, Override Alarms during Span & Zero Calibration, Sensor Fail Alarm • Gas Connections: 1/8" or 1/4” compression tube fittings or 1/8” female NPT • Menu Controls: Membrane Switch, Menu driven selection of Analysis Range, Display Resolution, Signal Filter Strength, Fine Tune Temp Compensation, Calibration, Alarm Setpoints and System Functions • Response Time: 90% of Step Change in <30 sec • Repeatability: +/-1% over all ranges • Recommended Sample Flow Rate: 1-2 SCFH, vent to atmosphere • Sample System Included: SS 316 Sensor Housing with Compressing Tube Fittings Gas Connectors • Sensor Model: AST-333 inert gases, AST-333-Z for gases containing more than 0.5% CO2 • Expected Sensor Life: 24 months @ 25ºC and 1 atm • Operating Temp: Range: 5ºC to 45ºC • Enclosure: Painted Aluminum 7” x 4.5” x 4” Panel Mount • Warranty: 12 months analyzer, 12 months sensor Optional Accessories/Equipment AST-100 sensor for analysis above 100 PPM RS232 or RS485 Communication *Specification validated during desing, subject to change without notice ISO 9001:2015 Quality System (909) 517 003 7 info@app liedsensing.com www.appliedsensin

 Open the catalog to page 1

All AST - Applied Sensing Technologies catalogs and technical brochures

  1. SRX-CA32-RTS

    1  Page

  2. SRX-CA32-4

    1  Page

  3. SRX-CA60-4

    1  Page

  4. SRZ-CA24-4

    1  Page

  5. SRX-CTE2

    1  Page

  6. SRX-CA60-RTS

    1  Page

  7. SRX-CT22D

    1  Page

  8. SRX-CT33

    1  Page

  9. SRX-CT23

    1  Page

  10. SRX-CT21

    1  Page

  11. SRZ-MA333

    1  Page

  12. SRZ-MA333-M

    1  Page

  13. SRZ-MA100-M

    1  Page

  14. SRX-MA100-M

    1  Page

  15. SRZ-MA100-4

    1  Page

  16. SRX-MGP-41

    1  Page

  17. SRX-MA333-M

    1  Page

  18. MODEL 1015PW

    1  Page

  19. MODEL 1019P

    1  Page

  20. MODEL1015-PW

    1  Page

  21. MODEL 1015

    1  Page

  22. SRX-MTL-2C

    1  Page

  23. Model 1012

    1  Page

  24. SRX-CT17A

    1  Page

  25. SRX-CT21A

    1  Page

  26. SRX-CT22A

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.