Omnia II - Ultimate Safety Compliance Instrument
4Pages

{{requestButtons}}

Catalog excerpts

Omnia II - Ultimate Safety Compliance Instrument - 1

AVAILABLE INTERFACES The Most Advanced Electrical Safety Compliance Analyzer in the Industry Ethernet (Optional) SAFETY & PRODUCTIVITY FEATURES Remote Safety Remote Safety Interlock Interlock Easily disable HV output Prompt & Hold Prompt & Provides alerts Hold & instructions between tests Multiple Multiple Languages Languages Active Link® Active Link Continuous power during test steps My Menu My Menu Customize your own shortcut menu DualCHEK® Dual Check Simultaneous Hipot and Ground Bond Internal Internal Multiplexer Multiplexer Available with optional HV multiplexer (4 or 8 ports) Modular Modular Multiplexer Multiplexer FailCHEK™ FailCHEK Confirms failure detection Cal-Alert Cal-Alert® Tracks and alerts for calibration Ramp-HI Ramp-HI® Reduce ramp time during DC Hipot Charge-LO Charge-LO® Arc Detection Arc Detection High frequency filter for corona detection WithStand® WithStand Automation Compatible Ground Bond Voltage Drop Monitor voltage drop vs resistance Automatic operator shock protection Our OMNIA® II Series is a complete line of multi-function electrical safety compliance analyzers designed to satisfy even the most demanding application requirements. We’ve included exclusive productivity-enhancing features and the latest in safety technology to make this product line the envy of the industry. With 6 models to choose from, a multi-language menu system and a variety of automation interfaces available, the OMNIA® II is ready for global deployment. Multi-Language user interface Basic PLC relay control Compatible with SC6540 multiplexers Find the Model that Fits Your Testing Needs ® Ground Bond Ground Continuity Insulation Resistance Leakage Current Confirms proper DUT connection Power Source Recommended Accredited cali

Open the catalog to page 1
Omnia II - Ultimate Safety Compliance Instrument - 2

OMNIA® II Series INPUT SPECIFICATIONS GROUND BOND TEST MODE 115/230 V Auto Range, ± 15 % Variation Output Voltage (Open Circuit Limit) Frequency Fuse Output Frequency DIELECTRIC WITHSTAND TEST MODE Output Rating Output Current 5 kV @ 50 mAAC 5 kV @ 100 mAAC (Models 825X) 6 kV @ 20 mADC Voltage Setting Resolution: Accuracy: 1V ± (2% of setting + 5 volts Range: Resolution: Range: Resolution: Range: Resolution: Range: Resolution: Range: Resolution: Range: Resolution: Accuracy: Range: Resolution: Resolution: Accuracy: Maximum Loading Range: Resolution: Accuracy: Dwell Timer Milliohm Offset...

Open the catalog to page 2
Omnia II - Ultimate Safety Compliance Instrument - 3

OMNIA® II Series RUN TEST MODE CONTINUED (Models 82X6 & 82X7 only) LEAKAGE CURRENT TEST MODE CONTINUED (Models 82X6 & 82X7 only) Trip Point Settings & Metering Touch Current Display (rms) Voltage Volt-Hi Volt-LO Range: Resolution: Accuracy: Range: Resolution: Accuracy: 0.1 μA DC: 15 Hz < f <100 KHz: ± (2% of reading + 3 counts) 100 KHz < f < 1 MHZ: ± 5% of reading (10.0 μA – 999.9 μA) Range 4: Power-HI Power-LO Range: Resolution: Accuracy: PF-HI PF-LO Range: Resolution: Accuracy: Range: Resolution: Accuracy: 0.0 – 999.9 seconds 0.1 second ± (0.1% of reading + 0.05 seconds) Voltage Display...

Open the catalog to page 3
Omnia II - Ultimate Safety Compliance Instrument - 4

OMNIA® II Series AC POWER SOURCE (82X7 only) Output GENERAL SPECIFICATIONS Input: Test, Reset, Interlock, Recall File 1 through 3 Output: Pass, Fail, Test-in-Process Built-in SmartGFI circuit Standard: USB/RS-232 Optional: Ethernet or GPIB Advanced security system with access levels and username/password requirements 4 .20 A maximum for 0 – 150 V range 2.10 A maximum 0 – 277 V range Regulation: Crest Factor: Test Timing: Limit: ≤ 0.5% + 5 V (resistive load), from no load to full load and Low Line to High Line (combined regulation) Steps when internal AC source is ON Low Range: High Range: ≤...

Open the catalog to page 4

All Associated Research catalogs and technical brochures

  1. HypotULTRA

    2 Pages

  2. HYAMP 3200

    2 Pages

  3. Hypot

    2 Pages

  4. HypotMAX

    2 Pages