AR Full Product Catalog 2021
34Pages

{{requestButtons}}

Catalog excerpts

AR Full Product Catalog 2021 - 1

Instruments for Electrical Safety Compliance Testing Experts In Electrical Safety Compliance.® Hipot • Ground Bond • Insulation Resistance • Leakage Current • Functional Run Medical Test Systems • HV/HC Multiplexers • Software

Open the catalog to page 1
AR Full Product Catalog 2021 - 2

CUSTOMER HAPPINESS PROMISE We aim to provide an amazing experience and quality testers that last a long time. If you’re not satisfied with your tester, return it within 45 days for a full refund. Calibrate annually with us, or one of our authorized partners, and we’ll extend your warranty an additional year for the service life of your tester, and at least five years after discontinuation. If it breaks during that time, we promise to fix it for free (unless abuse or excessive damage is present). When your tester reaches the end of its service life, we’ll responsibly recycle it and give you...

Open the catalog to page 2
AR Full Product Catalog 2021 - 3

Associated Research was founded. We introduced the first battery operated Megohmmeter, the Vibrotest, in the United States. We commenced the first Cable Testing/Fault Location school known as ARU. ARU continued for over 25 years. We introduced the first complete family of microprocessor-controlled electrical safety instruments. We developed the first multi-function electrical safety compliance analyzer. We released the first electrical safety instrument with a built-in multiplexer for multi-point testing. We introduced Autoware, the first software package for automated instrument control,...

Open the catalog to page 3
AR Full Product Catalog 2021 - 4

PRODUCT REFERENCE CHART Ground Bond Ground Continuity Insulation Resistance Leakage Current

Open the catalog to page 4
AR Full Product Catalog 2021 - 5

Internal Multiplexer Modular Multiplexer WithStand Compatible Power Source Recommended MedTEST is the most comprehensive Electrical Safety Compliance test system in the industry designed exclusively for medical applications. Customize it to meet your specific me

Open the catalog to page 5
AR Full Product Catalog 2021 - 6

Production Line Hipot Testing at its Finest AVAILABLE INTERFACES RoHS 3 Our Hypot® Series raises the bar for production line Hipot testing. Improve traceability with onboard data storage and easily transfer test result data and test settings via convenient front panel USB. Take the guesswork out of your production line with the direct barcode connection to quickly associate products with pre-programmed test files. We’ve included advanced features like improved security and a touch screen interface that provides custom pop-up prompts displayed before each test step. We’ve dramatically...

Open the catalog to page 6
AR Full Product Catalog 2021 - 7

Hypot® Series INPUT SPECIFICATIONS INSULATION RESISTANCE TEST MODE Voltage Setting Output Rating Maximum Limit Range: Resolution: Range: Resolution: Accuracy: Range: Resolution: Range: Resolution: Accuracy: Arc Detection Ground Fault Interrupt Range 1: Range 2: Range 3: All Ranges ± (2% of reading + 2 counts) ± (8% of reading+2 counts) at test voltage 30 – 499 V and 1.00–999.9 MΩ Range: Resolution: HV Shut Down Speed: < 1 msec AC Range: Resolution: GFI Trip Current: 450 µA max (AC or DC), Fixed At test voltage 500-1000 V ± (2% of reading + 2 counts) for 1.00 – 999.9 MΩ ± (5% of reading + 2...

Open the catalog to page 7
AR Full Product Catalog 2021 - 8

AVAILABLE INTERFACES The Most Flexible and Feature-Rich Automated Dielectric Analyzer Available Ethernet (Optional) SAFETY & PRODUCTIVITY FEATURES Remote Safety Remote Safety Interlock Interlock Data Transfer Data Transfer Direct barcode connection Multiple Multiple Languages Languages Multi-Language user interface Ground Bond Voltage Drop Monitor voltage drop vs resistance ProVOLT® ProVOLT™ Multi-dwell cycles at different voltages for ACW/DCW/IR Internal Internal Multiplexer Multiplexer Available with optional HV multiplexer (4 or 8 ports) Modular Modular Multiplexer Multiplexer FailCHEK™...

Open the catalog to page 8
AR Full Product Catalog 2021 - 9

HypotULTRA® Series INPUT SPECIFICATIONS INSULATION RESISTANCE MODE (Models 7800/7804/7850 & 7854 Only) Charging Current HI and LO-Limit Range: Resolution: Accuracy: Output Frequency Output Waveform Sine Wave, Crest Factor = 1.3 – 1.5 Output Regulation Range: Resolution: Range: Resolution: Accuracy: Ramp Up Timer Ramp Down Timer Dwell Timer Range: Range: Range: Range: Resolution: Range: Resolution: Accuracy: 0.000 – 9.999 mA 0.001 mA 10.00 – 40.00 mA (10 – 99.99 mA, Models 7800/7854) 0.01 mA ± (2% of setting + 2 counts) 7804/7820/7850 ± (2% of setting + 6 counts) 7800/7854 0.000 – 9.999 mA...

Open the catalog to page 9
AR Full Product Catalog 2021 - 10

AVAILABLE INTERFACES The Most Advanced Electrical Safety Compliance Analyzer in the Industry Ethernet (Optional) SAFETY & PRODUCTIVITY FEATURES Remote Safety Remote Safety Interlock Interlock Easily disable HV output Prompt & Hold Prompt & Provides alerts Hold & instructions between tests Multiple Multiple Languages Languages Active Link® Active Link Continuous power during test steps My Menu My Menu Customize your own shortcut menu DualCHEK® Dual Check Simultaneous Hipot and Ground Bond Internal Internal Multiplexer Multiplexer Available with optional HV multiplexer (4 or 8 ports) Modular...

Open the catalog to page 10
AR Full Product Catalog 2021 - 11

OMNIA® II Series INPUT SPECIFICATIONS GROUND BOND TEST MODE 115/230 V Auto Range, ± 15 % Variation Output Voltage (Open Circuit Limit) Frequency Fuse Output Frequency DIELECTRIC WITHSTAND TEST MODE Output Rating Output Current 5 kV @ 50 mAAC 5 kV @ 100 mAAC (Models 825X) 6 kV @ 20 mADC Voltage Setting Resolution: Accuracy: 1V ± (2% of setting + 5 volts Range: Resolution: Range: Resolution: Range: Resolution: Range: Resolution: Range: Resolution: Range: Resolution: Accuracy: Range: Resolution: Resolution: Accuracy: Maximum Loading Range: Resolution: Accuracy: Dwell Timer Milliohm Offset...

Open the catalog to page 11
AR Full Product Catalog 2021 - 12

OMNIA® II Series RUN TEST MODE CONTINUED (Models 82X6 & 82X7 only) LEAKAGE CURRENT TEST MODE CONTINUED (Models 82X6 & 82X7 only) Trip Point Settings & Metering Touch Current Display (rms) Voltage Volt-Hi Volt-LO Range: Resolution: Accuracy: Range: Resolution: Accuracy: 0.1 μA DC: 15 Hz < f <100 KHz: ± (2% of reading + 3 counts) 100 KHz < f < 1 MHZ: ± 5% of reading (10.0 μA – 999.9 μA) Range 4: Power-HI Power-LO Range: Resolution: Accuracy: PF-HI PF-LO Range: Resolution: Accuracy: Range: Resolution: Accuracy: 0.0 – 999.9 seconds 0.1 second ± (0.1% of reading + 0.05 seconds) Voltage Display...

Open the catalog to page 12

All Associated Research catalogs and technical brochures

  1. HypotULTRA

    2 Pages

  2. HYAMP 3200

    2 Pages

  3. Hypot

    2 Pages

  4. HypotMAX

    2 Pages