Catalog excerpts
positape® Tape Extension Position Sensor WB10ZG Displacement sensor with measurement length up to 2,000 mm Robust stainless steel measurement tape Multiple deflections possible With magnetic absolute encoder Product versions Analog output Analog output, programmable Digital output CANopen, SAE
Open the catalog to page 1WB10ZG - Tape Extension Position Sensor Version with analog output Specifications Order options Measurement range Voltage 0.5 ... 10 V Voltage 0.5 ... 4.5 V Current 4 ... 20 mA, 3 wire Signal characteristics ±0.10% f.s. (standard) ±0.05% f.s. (optional, only for measurement ranges ≥1000 mm) Sensing device Magnetic absolute encoder Zinc diecast, aluminum, TPU Tape: stainless steel, 10 mm wide, 0,08 mm thick Protection class IP65 (with mating connector only) Dust wiper Temperature range Order example: WB10ZG – 2000 – U2 – A – L10 – M12A5 – BAB1 Accessories: Connector cable (see page 16)
Open the catalog to page 2WB10ZG - Tape Extension Position Sensor Version with analog output, programmable Specifications Order options Measurement range Voltage 0.5 ... 10 V, programmable Voltage 0.5 ... 4.5 V, programmable Current 4 ... 20 mA, 3 wire, programmable Signal characteristics ±0.10% f.s. (standard) ±0.05% f.s. (optional, only for measurement ranges ≥1000 mm) Sensing device Magnetic absolute encoder Zinc diecast, aluminum, TPU Tape: stainless steel, 10 mm wide, 0,08 mm thick Protection class IP65 (with mating connector only) Dust wiper Temperature range Accessories: Connector cable (see page 17)
Open the catalog to page 3WB10ZG - Tape Extension Position Sensor Version with digital output SSI Specifications Order options Measurement range ±0.10% f.s. (standard) ±0.05% f.s. (optional, only for measurement ranges ≥1000 mm) Sensing device Magnetic absolute encoder Zinc diecast, aluminum, TPU Tape: stainless steel, 10 mm wide, 0,08 mm thick Protection class IP65 (with mating connector only) Dust wiper Temperature range Accessories: Connector cable (see page 18)
Open the catalog to page 4WB10ZG - Tape Extension Position Sensor Version with digital output CANopen, SAE J1939 Specifications Order options Measurement range ±0.10% f.s. (standard) ±0.05% f.s. (optional, only for measurement ranges ≥1000 mm) Sensing device Magnetic absolute encoder Zinc diecast, aluminum, TPU Tape: stainless steel, 10 mm wide, 0,08 mm thick Protection class IP65 (with mating connector only) Dust wiper Temperature range Accessories: Connector cable (see page 19)
Open the catalog to page 5A – 4 x M5-8 [.315] deep B – Connector M12 Dimensions in mm [inch] Dimensions informative only. For guaranteed dimensions consult factory.
Open the catalog to page 6A – 4 x M5-8 [.315] deep B – Connector M12 Dimensions in mm [inch] Dimensions informative only. For guaranteed dimensions consult factory.
Open the catalog to page 7positape® WB10ZG Output specification Analog output Excitation voltage Excitation current Output voltage Output current Measuring rate Stability (temperature) Reverse polarity, short circuit Operating temperature See specification of the respective sensor Excitation voltage Excitation current Output voltage Output current Measuring rate Stability (temperature) Reverse polarity, short circuit Operating temperature See specification of the respective sensor Excitation voltage Current output Excitation current Output current Measuring rate Stability (temperature) Reverse polarity, short...
Open the catalog to page 8Signal wiring Connector M12, 5 pin Output signals Cable color View to the sensor connector
Open the catalog to page 9positape® WB10ZG Analog output, programmable Excitation voltage Excitation current Output voltage Output current Measuring rate Stability (temperature) Reverse polarity, short circuit Operating temperature See specification of the respective sensor Excitation voltage Excitation current Output voltage Output current Measuring rate Stabilität (Temperatur) Reverse polarity, short circuit Operating temperature See specification of the respective sensor Excitation voltage Excitation current Output current Measuring rate Stability (temperature) Reverse polarity, short circuit Operating...
Open the catalog to page 10positape® WB10ZG Output …/PMU Programming of the start and end value by the customer (programmable) Teach-In of start and end value for the analog outputs U2/PMU, U8/PMU, I1/PMU is provided by a binary signal SPAN/ZERO. At the start position connect signal SPAN/ZERO for a period of 2 ... 3 seconds to GND via push button. At the end position connect signal SPAN/ZERO for a period of 5 ... 6 seconds to GND via a push button. The scaling range will be stored non-volatile. To reset the sensor to factory default ZERO/END must be connected to ground while powering up the sensor for 2 … 3 seconds....
Open the catalog to page 11positape® WB10ZG Digital output MSSI Excitation voltage Excitation current Clock frequency Gray-Code, continuous progression Delay between pulse trains (tp) Stability (temperature) Operating temperature See specification of the respective sensor Reverse polarity, short circuit Data format (Train of 26 pulses) Transmission rate Baud rate Extension of the cable length will reduce the maximum transmission rate. Signal wiring Connector M12, 8 pin Cable length Cable color View to the sensor connector Output signals
Open the catalog to page 12Communication profile Encoder profile Error Control Node Guarding, Heartbeat, Emergency Message 3 TxPDO, 0 RxPDO, no linking, static mapping Event-/Time triggered, Remote-request, Sync cyclic/acyclic Transmission rate 50 kBit bis 1 Mbit, adjustable via LSS or SDO, default: 125 kBit Integrated bus terminating resistor Excitation voltage Excitation current Measuring rate Stability (temperature) Operating temperature See specification of the respective sensor Reverse polarity, short circuit Dielectric strength Signal wiring Connector M12, 5 pin Output signals Cable color View to the sensor...
Open the catalog to page 13Communication profile Baud Rate Internal termination resistor Arbitrary address capable Industry group Vehicle system Vehicle system instance Function instance Identity number Configuration data Process data Proprietary-B (PDU2 broadcast); nn Group Extension (PS) configurable Excitation voltage Excitation current Measuring rate Stability (temperature) Operating temperature See specification of the respective sensor Reverse polarity, short circuit Dielectric strength NAME Fields Parameter Group Numbers (PGN)
Open the catalog to page 14All ASM Automation Sensorik Messtechnik GmbH catalogs and technical brochures
-
PD-INC
7 Pages
-
PD-ADC
7 Pages
-
System NMG2
4 Pages
-
PTK7
9 Pages
-
PTK6
9 Pages
-
PTK29
7 Pages
-
PTDM7
8 Pages
-
PTAM7
12 Pages
-
PTDM6
8 Pages
-
PTAM6
13 Pages
-
PTDM5
10 Pages
-
PTAM5
13 Pages
-
PTAM4
9 Pages
-
PTAM2
16 Pages
-
PTAM27
9 Pages
-
PTM27
10 Pages
-
PTM29
10 Pages
-
AWS
5 Pages
-
PH68
19 Pages
-
PH58
21 Pages
-
PH36
21 Pages
-
PRDS7
22 Pages
-
PRAS7
18 Pages
-
PRDS6
23 Pages
-
PRAS6
19 Pages
-
PRAS4
8 Pages
-
PRDS3
16 Pages
-
PRDS2
21 Pages
-
PRDS5
28 Pages
-
PRAS5
25 Pages
-
PRAS4
8 Pages
-
PRDS3
21 Pages
-
PRAS3
19 Pages
-
PRDS2
26 Pages
-
PRAS2
22 Pages
-
PRAS5
25 Pages
-
PRAS4
8 Pages
-
PRDS3
21 Pages
-
PRAS3
19 Pages
-
PRDS1
13 Pages
-
PRAS1
12 Pages
-
PRAS29
15 Pages
-
PRAS27
16 Pages
-
PRAS26
13 Pages
-
PRAS20
12 Pages
-
PMIB3
7 Pages
-
PMIS3
8 Pages
-
posichron® EasyMount
6 Pages
-
PCRP32
18 Pages
-
PCST27
26 Pages
-
PCST25
27 Pages
-
PCST24
29 Pages
-
PCRP21
23 Pages
-
PCQA24
24 Pages
-
PCQA22
24 Pages
-
PCFP25
22 Pages
-
PCFP24
22 Pages
-
PCFP23
24 Pages
-
WB100M
21 Pages
-
WST 21
9 Pages
-
WB21
26 Pages
-
WST85
6 Pages
-
WB85
22 Pages
-
WST61
6 Pages
-
WB61
22 Pages
-
WB12
23 Pages
-
WS7.0
6 Pages
-
LR19
6 Pages
-
WS12EX
8 Pages
-
WS10EX
8 Pages
-
WS58C
9 Pages
-
WS100M
24 Pages
-
WS60
12 Pages
-
WS7.5
41 Pages
-
WBT21
11 Pages
-
WS21
25 Pages
-
WBT61
7 Pages
-
WBT85
7 Pages
-
WS85
22 Pages
-
WS61
22 Pages
-
WS19KT
11 Pages
-
WS19KT
16 Pages
-
WS17KT
16 Pages
-
WS12
39 Pages
-
WS10
36 Pages
-
WS10ZG
36 Pages
-
WS10SG
36 Pages
-
WS42C
8 Pages
-
WS42
10 Pages
-
WS31C
8 Pages
-
WS31
10 Pages
-
PTM27
10 Pages
-
ASM Product Overview
40 Pages