posirot® Magnetic Angle Sensors PRDS5 Angle sensor for heavy duty applications Protection class IP67/IP69, IP68 optional Hermetically sealed stainless steel housing Longitudinal water barrier; potted electronics Measurement with 10 mm shaft or contactless Optional CAN output with self diagnostics function Product versions Incremental output Digital output CANopen/SAE J1939 (optio
Open the catalog to page 1PRDS5 - Magnetic Angle Sensor Version with incremental output Specifications Order options Mechanical connection Shaft 10 mm Contactless with external position magnet Measurement range Incremental encoder output RS422 compatible output with excitation 5 V DC Incremental encoder output RS422 compatible output with excitation 8 ... 36 V Incremental encoder output HTL compatible output with excitation 8 ... 36 V Rated distance sensor / magnet Depending on the position magnet (only version K) 8-pin connector M12, axial 8-pin connector M12, radial Cable, standard length 2 m Deutsch connector, not...
Open the catalog to page 2PRDS5 - Magnetic Angle Sensor Version with digital output SSI Specifications Order options Mechanical connection Shaft 10 mm Contactless with external position magnet Measurement range Synchronous serial output with excitation 5 V DC Synchronous serial output with excitation 10 ... 36 V Code characteristics Signal increasing CW, clockwise Signal increasing CCW, counterclockwise Rated distance sensor / magnet Depending on the position magnet (only version K) 8-pin connector M12, axial 8-pin connector M12, radial Cable, standard length 2 m Deutsch connector, not shielded Housing material Stainless...
Open the catalog to page 3PRDS5 - Magnetic Angle Sensor Version with digital output CANopen/SAE J1939 (optional redundant) Specifications Order options Mechanical connection Shaft 10 mm Contactless with external position magnet Measurement range CANopen CAN SAE J1939 CANopen, redundant CAN SAE J1939, redundant Rated distance sensor / magnet Depending on the position magnet (only version K) 5-pin connector M12 axial 5-pin connector M12 radial Deutsch connector, not shielded Housing material Stainless steel EN 1.4404 (AISI 316L) Protection class Life cycle of bearings (shaft version) Revolutions per minute (mechanical)...
Open the catalog to page 4Dimensions Contactless, connector M12, axial D A – Position magnet B – Marking C – Measuring area D – Connector M12 Dimensions in mm [inch]. Dimensions informative only. For guaranteed dimensions consult factory.
Open the catalog to page 5Contactless, connector M12, radial A – Position magnet B – Marking C – Measuring area D – Connector M12 Dimensions in mm [inch]. Dimensions informative only. For guaranteed dimensions consult factory.
Open the catalog to page 6Cable version, contactless A A – Position magnet B – Marking C – Measurement area Dimensions in mm [inch]. Dimensions informative only. For guaranteed dimensions consult factory.
Open the catalog to page 7With shaft, connector M12, axial Dimensions in mm [inch]. Dimensions informative only. For guaranteed dimensions consult factory.
Open the catalog to page 8With shaft, connector M12, radial Dimensions in mm [inch]. Dimensions informative only. For guaranteed dimensions consult factory.
Open the catalog to page 9Cable version, with shaft Dimensions in mm [inch]. Dimensions informative only. For guaranteed dimensions consult factory.
Open the catalog to page 10Order code zinc coated steel, plastic A misalignment of the position magnet has an effect on the linearity. Dimensions in mm [inch]. Dimensions informative only. For guaranteed dimensions please consult factory.
Open the catalog to page 11Order code zinc coated steel; plastic A misalignment of the position magnet has an effect on the linearity. Dimensions in mm [inch] Dimensions informative only. For guaranteed dimensions please consult factory.
Open the catalog to page 12Order code zinc coated steel, plastic A misalignment of the position magnet has an effect on the linearity. Dimensions in mm [inch]. Dimensions informative only For guaranteed dimensions please consult factory.
Open the catalog to page 13A – Sensor B – Marking C – Notch Order code stainless steel EN 1.4404 (AISI 316L) A misalignment of the position magnet has an effect on the linearity. Dimensions in mm [inch]. Dimensions informative only. For guaranteed dimensions please consult factory.
Open the catalog to page 14Measuring error by misalignment of the position magnet Air gap (a) Parallelism (b) Axial misalignment (c) Error by axial misalignment [°] Position magnet
Open the catalog to page 15Output specification Incremental output RS5VF /RS24VF Incremental Excitation voltage Excitation current Output current Stability (temperature) Operating temperature Short circuit Output signals Output signals Signal wiring Connector M12, 8 pin Pulse sequence for clockwise rotation CW in view of shaft or active front of sensor. A zero impulse Z, Z is generated at the reference position. Cable color B View to the sensor connector Output signals
Open the catalog to page 16Excitation voltage Excitation current Output current Stability (temperature) Operating temperature Short circuit Output signals Output signals Signal wiring Connector M12, 8 pin Pulse sequence for clockwise rotation CW in view of shaft or active front of sensor. A zero impulse Z, Z is generated at the reference position. Cable color A View to the sensor connector Output signals
Open the catalog to page 17SSI output RSSI5V/RSSI24V Synchronous serial SSI Excitation voltage Excitation current Clock frequency Gray-Code, continuous progression, 12 bit Delay between pulse trains Stability (temperature) Operating temperature Refer to sensor specifications Short circuit Data format (Train of 13 pulses) Transmission rate Baud rate Signal wiring Connector M12, 8 pin Cable length Extension of the cable length will reduce the maximum transmission rate. The ��������� �������� signals CLOCK /CLOCK and DATA/DATA must be connected in a twisted pair cable, shielded in pairs, the pairs also commonly shielded....
Open the catalog to page 18Digital output CANopen CANOP Communication profile Device profile Configuration services Layer Setting Service (LSS), CiA Draft Standard 305 (transmission rate, node id) Error Control Node Guarding, Heartbeat, Emergency Message 3 TxPDO, 0 RxPDO, static mapping Event-/Time triggered, Remote-request, Sync cyclic/acyclic Transmission rates 50 kBaud to 1 MBaud, default: 125 kBaud; programmable via LSS or SDO Integrated bus terminating resistor Excitation voltage Excitation current Stability (temperature) Operating temperature See specification of the respective sensor Reverse polarity, short circuit...
Open the catalog to page 194 Pages
9 Pages
9 Pages
7 Pages
8 Pages
12 Pages
8 Pages
13 Pages
10 Pages
13 Pages
9 Pages
16 Pages
9 Pages
10 Pages
5 Pages
19 Pages
21 Pages
21 Pages
18 Pages
19 Pages
25 Pages
8 Pages
19 Pages
12 Pages
15 Pages
16 Pages
13 Pages
12 Pages
7 Pages
8 Pages
6 Pages
18 Pages
26 Pages
27 Pages
29 Pages
23 Pages
24 Pages
24 Pages
22 Pages
22 Pages
24 Pages
21 Pages
9 Pages
26 Pages
6 Pages
22 Pages
6 Pages
22 Pages
23 Pages
20 Pages
6 Pages
6 Pages
8 Pages
8 Pages
9 Pages
24 Pages
12 Pages
41 Pages
11 Pages
25 Pages
7 Pages
7 Pages
22 Pages
22 Pages
11 Pages
16 Pages
16 Pages
39 Pages
36 Pages
36 Pages
36 Pages
8 Pages
10 Pages
8 Pages
10 Pages
10 Pages
40 Pages