posirot® Magnetic Angle Sensors PRAS5 Angle sensor for heavy duty applications Protection class IP67/IP69, IP68 optional Hermetically sealed stainless steel housing Longitudinal water barrier; potted electronics Measurement with 10 mm shaft or contactless Product versions Analog output Analog output,
Open the catalog to page 1PRAS5 - Magnetic Angle Sensor Version with analog output Specifications Order options Mechanical connection Shaft 10 mm Contactless with external position magnet Measurement range Voltage 0.5 ... 10 V Voltage 0.5 ... 4.5 V ratiometric Voltage 0.5 ... 4.5 V Current 4 ... 20 mA, 3 wire Signal characteristics Signal increasing CW, clockwise Signal increasing CCW, counterclockwise 5-pin connector M12 axial (compatible with 4-pin connector) 5-pin connector M12 radial (compatible with 4-pin connector) Cable, standard length 2 m Deutsch connector, not shielded Housing material Stainless steel EN 1.4404...
Open the catalog to page 2Order example: PRAS5 – V – 360 – I1 – CW – M12A5 – VA Accessories: Connector cable (see page 24) Position magnets (see from page 12)
Open the catalog to page 3PRAS5 - Magnetic Angle Sensor Version with analog output, redundant Specifications Order options Mechanical connection Shaft 10 mm Contactless with external position magnet Measurement range Voltage 0.5 ... 10 V, redundant Voltage 0.5 ... 4.5 V ratiometric, redundant Voltage 0.5 ... 4.5 V, redundant Current 4... 20 mA, 3 wire, redundant Signal characteristics Signal 1 increasing clockwise, signal 2 increasing counterclockwise Signal 1 and signal 2 increasing clockwise* Signal 1 and signal 2 increasing counterclockwise* CW/CCW CW/CW CCW/CCW * not available with output I1R Resolution 8-pin connector...
Open the catalog to page 4Order example: PRAS5 – V – 360 – U2R – CW/CCW – M12R8 – VA Accessories: Connector cable (see page 25) Position magnets (see from page 12)
Open the catalog to page 5Dimensions Contactless, connector M12, axial D A – Position magnet B – Marking C – Measuring area D – Connector M12 Dimensions in mm [inch]. Dimensions informative only. For guaranteed dimensions consult factory.
Open the catalog to page 6Contactless, connector M12, radial A – Position magnet B – Marking C – Measuring area D – Connector M12 Dimensions in mm [inch]. Dimensions informative only. For guaranteed dimensions consult factory.
Open the catalog to page 7Cable version, contactless A A – Position magnet B – Marking C – Measurement area Dimensions in mm [inch]. Dimensions informative only. For guaranteed dimensions consult factory.
Open the catalog to page 8With shaft, connector M12, axial Dimensions in mm [inch]. Dimensions informative only. For guaranteed dimensions consult factory.
Open the catalog to page 9With shaft, connector M12, radial Dimensions in mm [inch]. Dimensions informative only. For guaranteed dimensions consult factory.
Open the catalog to page 10Cable version, with shaft Dimensions in mm [inch]. Dimensions informative only. For guaranteed dimensions consult factory.
Open the catalog to page 11Order code zinc coated steel, plastic A misalignment of the position magnet has an effect on the linearity. Dimensions in mm [inch]. Dimensions informative only. For guaranteed dimensions please consult factory.
Open the catalog to page 12Order code zinc coated steel; plastic A misalignment of the position magnet has an effect on the linearity. Dimensions in mm [inch] Dimensions informative only. For guaranteed dimensions please consult factory.
Open the catalog to page 13Order code zinc coated steel, plastic A misalignment of the position magnet has an effect on the linearity. Dimensions in mm [inch]. Dimensions informative only For guaranteed dimensions please consult factory.
Open the catalog to page 14A – Sensor B – Marking C – Notch Order code stainless steel EN 1.4404 (AISI 316L) A misalignment of the position magnet has an effect on the linearity. Dimensions in mm [inch]. Dimensions informative only. For guaranteed dimensions please consult factory.
Open the catalog to page 15Measuring error by misalignment of the position magnet Air gap (a) Parallelism (b) Axial misalignment (c) Error by axial misalignment [°] Position magnet
Open the catalog to page 16Output specification Analog output U2 Voltage output 0.5 ... 10 V Excitation current Output voltage Output current Measuring rate Stability (temperature) Reverse polarity, short circuit Operating temperature Excitation voltage Excitation current Output voltage Output current Measuring rate Stability (temperature) Reverse polarity, short circuit Operating temperature Excitation voltage
Open the catalog to page 17U6 Voltage output 10 … 90 % ratiometric Excitation current Output voltage Output current Measuring rate Stability (temperature) Reverse polarity, short circuit Operating temperature Excitation voltage Excitation current Output voltage Output current Measuring rate Stability (temperature) Reverse polarity, short circuit Operating temperature Excitation voltage
Open the catalog to page 18I1 Current output 4 … 20 mA, 3 wires Excitation current Output current Measuring rate Stability (temperature) Reverse polarity, short circuit Operating temperature Excitation voltage Excitation current Output current Measuring rate Stability (temperature) Reverse polarity, short circuit Operating temperature I1B Current output 4 … 20 mA, 3 wires Excitation voltage Analog output, 1 channel (connector output) Signal wiring Connector M12, 5 pin Cable color Do not connect! View to the sensor connector Output signals 3-wire current 4...20 mA interface: GND has to be connected!
Open the catalog to page 19Analog output (cable output, seawater resistant submarine cable) Signal wiring Output signals Cable color 3-wire current 4...20 mA interface: GND has to be connected!
Open the catalog to page 20Analog output, redundant U2R Voltage output 0.5 ... 10 V Excitation current Output voltage Output current Measuring rate Stability (temperature) Reverse polarity, short circuit Operating temperature Excitation voltage Excitation current Output voltage Output current Measuring rate Stability (temperature) Reverse polarity, short circuit Operating temperature U6R Voltage output 10 … 90 % ratiometric Excitation voltage
Open the catalog to page 21Excitation current Output voltage Output current Measuring rate Stability (temperature) Reverse polarity, short circuit Operating temperature Excitation voltage Excitation current Output current Measuring rate Stability (temperature) Reverse polarity, short circuit Operating temperature I1R Current output 4 … 20 mA, 3 wires Excitation voltage Analog output, 2 channels, redundant (connector and cable output) Signal wiring Connector M12, 8 pin Output signals Cable color 2 View to the sensor connector
Open the catalog to page 224 Pages
9 Pages
9 Pages
7 Pages
8 Pages
12 Pages
8 Pages
13 Pages
10 Pages
13 Pages
9 Pages
16 Pages
9 Pages
10 Pages
5 Pages
19 Pages
21 Pages
21 Pages
18 Pages
19 Pages
8 Pages
19 Pages
12 Pages
15 Pages
16 Pages
13 Pages
12 Pages
7 Pages
8 Pages
6 Pages
18 Pages
26 Pages
27 Pages
29 Pages
23 Pages
24 Pages
24 Pages
22 Pages
22 Pages
24 Pages
21 Pages
9 Pages
26 Pages
6 Pages
22 Pages
6 Pages
22 Pages
23 Pages
20 Pages
6 Pages
6 Pages
8 Pages
8 Pages
9 Pages
24 Pages
12 Pages
41 Pages
11 Pages
25 Pages
7 Pages
7 Pages
22 Pages
22 Pages
11 Pages
16 Pages
16 Pages
39 Pages
36 Pages
36 Pages
36 Pages
8 Pages
10 Pages
8 Pages
10 Pages
10 Pages
40 Pages