posichron® Magnetostrictive Position Sensors PCFP24 Displacement sensor in flat profile for tight mounting spaces Ultra flat profile housing: only 12 mm high Wear and maintenance free High level of shock resistance up to 50 g (100 shocks) Guiding distance of up to 19 mm (depending on magnet/profile) Product versions Analog output, 1 channel Analog output, 2 channels Digital output
Open the catalog to page 1PCFP24 - Magnetostricitve Position Sensor in flat profile Version with analog output, 1 channel Specifications Order options, 1 channel Measurement range 100 ... 5750 (in 10 mm increments) other lengths upon request 0 ... 10 V signal conditioner U1 with alarm_HOLD 0.5 ... 10 V signal conditioner U2 with alarm_LOW; U2 with alarm_HOLD 0.5 ... 4.5 V signal conditioner U8 with alarm_LOW; U8 with alarm_HOLD 4 ... 20 mA signal conditioner (3 wire) I1 with alarm_LOW; I1with alarm_HOLD Function and characteristics output Position magnet 1, increasing Position magnet 1, decreasing Start value, direction...
Open the catalog to page 2PCFP24 - Magnetostricitve Position Sensor in flat profile Version with analog output, 2 channels Specifications Order options, 2 channels Measurement range 100 ... 5750 (in 10 mm increments) other lengths upon request 0 ... 10 V signal conditioner U1 with alarm_HOLD 0.5 ... 10 V signal conditioner U2 with alarm_LOW; U2 with alarm_HOLD 0.5 ... 4.5 V signal conditioner U8 with alarm_LOW; U8 with alarm_HOLD 4 ... 20 mA signal conditioner (3 wire) I1 with alarm_LOW; I1with alarm_HOLD Function and characteristics, output 1 Position magnet 1, increasing Position Magnet 1, decreasing Difference magnet...
Open the catalog to page 31) VZx.x = velocity with direction detection (with 1 magnet only), in steps of 0.1 m/s Example: VZ1.5 towards start position 2) VAx.x = velocity without direction detection (with 1 magnet only), in steps of 0.1 m/s Example: VA1.5 towards start position Accessories: Connector cable (see page 21) Position magnets (see page 10) Mounting set (see page 8)
Open the catalog to page 4PCFP24 - Magnetostricitve Position Sensor in flat profile Version with digital output SSI Specifications Order options Measurement range 100 ... 5750 (in 10 mm increments) other lengths upon request Synchronous serial interface (SSI) Output code Gray Dual Number of data bits Sampling rate Up to 1 kHz, depending on the measurement range Housing material Protection class IP67 (optional IP67/IP69; connector version: with mating connector only) Cable, standard length 2 m Temperature range Order example: PCFP24 – 1000 – 5 – SSI / G / 24 ‒ L10 – KAB2M Accessories: Position magnets (see page 10) Mounting...
Open the catalog to page 5PCFP24 - Magnetostricitve Position Sensor in flat profile Version with digital output CANopen Specifications Order options Measurement range 100 ... 5750 (in 10 mm increments) other lengths upon request CANopen-Bus CANopen-Bus with integrated terminating resistance CAN SAE J1939 CAN SAE J1939-Bus with integrated terminating resistance Sampling rate Up to 1 kHz, depending on the measurement range Housing material Protection class IP67 (optional IP67/IP69; connector version: with mating connector only) Cable (length 0.3 m) with connector M12, 5 pin Temperature range Order example: PCFP24 – 1000...
Open the catalog to page 6Dimensions Cable output 39 [1.535] B PCM AG 5 A – Start position B – End position C – Total length = Measurement length + 165 [6.496] (e.g. 265 [10.433]) D – Mounting set PCQA-BFS1 E – Measurement length (e.g. 100 [3.937] ) Cable: outer diameter 5.2 mm ±0.2 mm Wire cross sectional area 0.14 mm2 Dimensions in mm [inch] Dimensions informative only. For guaranteed dimensions consult factory.
Open the catalog to page 7Mounting sets Mounting set PCFP24-BFS1 A – Isolation sleeve B – Isolation strip C – Mounting clamp Dimensions in mm [inch] Dimensions informative only. For guaranteed dimensions consult factory.
Open the catalog to page 8Option -BFW Mounting brackets for PCFP24 The option -BFW can only be ordered with a new sensor, not separately! Applicable for sensor lengths up to 1000 mm. Not combinable with PCFP24-BFS1. Dimensions in mm [inch] Dimensions informative only. For guaranteed dimensions consult factory
Open the catalog to page 9Magnets PCMAG5 Standard magnet Dimensions in mm [inch] Dimensions informative only. For guaranteed dimensions consult factory.
Open the catalog to page 10Output specification Analog output U1 Voltage output 0 ... 10 V Excitation current Output voltage Output current Output load Stability (temperature) Reverse polarity, short circuit Output noise Operating temperature Excitation voltage Excitation current Output voltage Output current Output load Stability (temperature) Reverse polarity, short circuit Output noise Operating temperature Excitation voltage
Open the catalog to page 11Excitation current Output voltage Output current Output load Stability (temperature) Reverse polarity, short circuit Output noise Operating temperature I1 Current output 4 … 20 mA, 3 wire Excitation voltage Excitation voltage Excitation current Output current Stability (temperature) Reverse polarity, short circuit Output noise Operating temperature
Open the catalog to page 12Signal wiring Connector M8, 4 pin Output signals View to the sensor connector Signal wiring Connector M12, 8 pin Cable color SPAN/ZERO (PMU only, optional) View to the sensor connector Output signals * When using two magnets, the distance between the magnets must be min. 70 mm to identify the single magnets definitely.
Open the catalog to page 13Diagnostic on analog outputs Behaviour of the analog signal output in case of error In case of error (magnet missing or outside the measuring range) the analog output signal will assume a state according to the following options: Alarm_HIGH The output voltage resp. the output current is at HIGH level (overrange). Alarm_LOW The output voltage resp. the output current is at LOW level (underrange). Alarm_HOLD The output voltage resp. the output current will keep the last valid state. keeps last valid state (Order code U1/H) Uout < 0.25 V (Order code U2/U) keeps last valid state (Order code U2/H)...
Open the catalog to page 14Synchronous serial interface SSI Excitation voltage 10 … 36 V DC, residual ripple 10 mVss Excitation current Clock frequency Gray-Code, Dual-Code Delay between pulse trains (tp) Stability (temperature) Operating temperature The data transmission takes place by means of the two signals CLOCK and DATA. The processing unit (PLC, microcomputer) sends pulse sequences which clock the data transmission at the required transfer rate. With the first falling edge of the pulse sequence the position of the sensor is recorded and stored. The following rising edges control the bit-by-bit transfer of the data...
Open the catalog to page 154 Pages
9 Pages
9 Pages
7 Pages
8 Pages
12 Pages
8 Pages
13 Pages
10 Pages
13 Pages
9 Pages
16 Pages
9 Pages
10 Pages
5 Pages
19 Pages
21 Pages
21 Pages
18 Pages
19 Pages
25 Pages
8 Pages
19 Pages
12 Pages
15 Pages
16 Pages
13 Pages
12 Pages
7 Pages
8 Pages
6 Pages
18 Pages
26 Pages
27 Pages
29 Pages
23 Pages
24 Pages
24 Pages
22 Pages
24 Pages
21 Pages
9 Pages
26 Pages
6 Pages
22 Pages
6 Pages
22 Pages
23 Pages
20 Pages
6 Pages
6 Pages
8 Pages
8 Pages
9 Pages
24 Pages
12 Pages
41 Pages
11 Pages
25 Pages
7 Pages
7 Pages
22 Pages
22 Pages
11 Pages
16 Pages
16 Pages
39 Pages
36 Pages
36 Pages
36 Pages
8 Pages
10 Pages
8 Pages
10 Pages
10 Pages
40 Pages