Catalog excerpts
posichron® Magnetostrictive Position Sensors PCFP23 Displacement sensor in flat profile for tight mounting spaces Wear and maintenance free High level of shock resistance up to 50 g (100 shocks) Guiding distance of up to 19 mm (depending on magnet/profile) Product versions Analog output, 1 channel Analog output, 2 channels
Open the catalog to page 1PCFP23 - Magnetostricitve Position Sensor in flat profile Version with analog output, 1 channel Specifications Order options, 1 channel Measurement range 100 ... 5750 (in 10 mm increments) other lengths upon request 0 ... 10 V signal conditioner U1 with alarm_HOLD 0.5 ... 10 V signal conditioner U2 with alarm_LOW; U2 with alarm_HOLD 0.5 ... 4.5 V signal conditioner U8 with alarm_LOW; U8 with alarm_HOLD 4 ... 20 mA signal conditioner (3 wire) I1 with alarm_LOW; I1with alarm_HOLD Function and characteristics output Position magnet 1, increasing Position magnet 1, decreasing Start value,...
Open the catalog to page 2PCFP23 - Magnetostricitve Position Sensor in flat profile Version with analog output, 2 channels Specifications Order options, 2 channels Measurement range 100 ... 5750 (in 10 mm increments) other lengths upon request 0 ... 10 V signal conditioner U1 with alarm_HOLD 0.5 ... 10 V signal conditioner U2 with alarm_LOW; U2 with alarm_HOLD 0.5 ... 4.5 V signal conditioner U8 with alarm_LOW; U8 with alarm_HOLD 4 ... 20 mA signal conditioner (3 wire) I1 with alarm_LOW; I1with alarm_HOLD Function and characteristics, output 1 Position magnet 1, increasing Position Magnet 1, decreasing Difference...
Open the catalog to page 31) VZx.x = velocity with direction detection (with 1 magnet only), in steps of 0.1 m/s Example: VZ1.5 towards start position 2) VAx.x = velocity without direction detection (with 1 magnet only), in steps of 0.1 m/s Example: VA1.5 towards start position Accessories: Connector cable (see page 23) Position magnets (see page 12) Mounting set (see page 10)
Open the catalog to page 4PCFP23 - Magnetostricitve Position Sensor in flat profile Version with digital output SSI Specifications Order options Measurement range 100 ... 5750 (in 10 mm increments) other lengths upon request Synchronous serial interface (SSI) Output code Gray Dual Number of data bits Sampling rate Up to 1 kHz, depending on the measurement range Housing material Protection class Cable, standard length 2 m Temperature range Order example: PCFP23 – 1000 – 5 – SSI / G / 24 ‒ L10 – KAB2M Accessories: Position magnets (see page 12) Mounting sets (see page 10)
Open the catalog to page 5PCFP23 - Magnetostricitve Position Sensor in flat profile Version with digital output CANopen Specifications Order options Measurement range 100 ... 5750 (in 10 mm increments) other lengths upon request CANopen-Bus CANopen-Bus with integrated terminating resistance CAN SAE J1939 CAN SAE J1939-Bus with integrated terminating resistance Sampling rate Up to 1 kHz, depending on the measurement range Housing material Protection class Cable (length 0.3 m) with connector M12, 5 pin Temperature range Order example: PCFP23 – 1000 – CANOP – L10 – KAB0,3M-M12/CAN Accessories: Connector cable (see page...
Open the catalog to page 6Dimensions Cable output 39 [1. 535] A – Start position B – End position C – Total length = Measurement length + 15 [5.906] (e.g. 250 [9.483]) D – Mounting set PCFP23-BFS1 E – Measurement length (e.g. 100 [3.937] ) Cable: outer diameter 5.2 mm ±0.2 mm Wire cross sectional area 0.14 mm2 Dimensions in mm [inch] Dimensions informative only. For guaranteed dimensions consult factory.
Open the catalog to page 7A – Start position B – End position C – Total length = Measurement length + 150 [5.906] (e.g. 250 [9.843]) D – Mounting set PCFP23-BFS1 E – Measurement length (e.g. 100 [3.937]) Dimensions in mm [inch] Dimensions informative only. For guaranteed dimensions consult factory.
Open the catalog to page 8PCFP23 ‒ redundant Version with 2 sensors Horizontal arrangement Vertikal arrangement
Open the catalog to page 9Mounting sets A – Isolation sleeve B – Isolation strip C – Mounting clamp Dimensions in mm [inch] Dimensions informative only. For guaranteed dimensions consult factory.
Open the catalog to page 10Option -BFW Mounting brackets for PCFP23 The option -BFW can only be ordered with a new sensor, not separately! Applicable for sensor lengths up to 1000 mm. Not combinable with PCFP23-BFS1. Dimensions in mm [inch] Dimensions informative only. For guaranteed dimensions consult factory
Open the catalog to page 11Magnets PCMAG5 Standard magnet Dimensions in mm [inch] Dimensions informative only. For guaranteed dimensions consult factory.
Open the catalog to page 12Output specification Analog output U1 Voltage output 0 ... 10 V Excitation current Output voltage Output current Output load Stability (temperature) Reverse polarity, short circuit Output noise Operating temperature Excitation voltage Excitation current Output voltage Output current Output load Stability (temperature) Reverse polarity, short circuit Output noise Operating temperature Excitation voltage
Open the catalog to page 13Excitation current Output voltage Output current Output load Stability (temperature) Reverse polarity, short circuit Output noise Operating temperature I1 Current output 4 … 20 mA, 3 wire Excitation voltage Excitation voltage Excitation current Output current Stability (temperature) Reverse polarity, short circuit Output noise Operating temperature
Open the catalog to page 14Signal wiring Connector M8, 4 pin Output signals View to the sensor connector Signal wiring Connector M12, 8 pin Cable color SPAN/ZERO (PMU only, optional) View to the sensor connector Output signals * When using two magnets, the distance between the magnets must be min. 70 mm to identify the single magnets definitely.
Open the catalog to page 15Diagnostic on analog outputs Behaviour of the analog signal output in case of error In case of error (magnet missing or outside the measuring range) the analog output signal will assume a state according to the following options: Alarm_HIGH The output voltage resp. the output current is at HIGH level (overrange). Alarm_LOW The output voltage resp. the output current is at LOW level (underrange). Alarm_HOLD The output voltage resp. the output current will keep the last valid state. keeps last valid state (Order code U1/H) Uout < 0.25 V (Order code U2/U) keeps last valid state (Order code...
Open the catalog to page 16All ASM Automation Sensorik Messtechnik GmbH catalogs and technical brochures
-
PD-INC
7 Pages
-
PD-ADC
7 Pages
-
System NMG2
4 Pages
-
PTK7
9 Pages
-
PTK6
9 Pages
-
PTK29
7 Pages
-
PTDM7
8 Pages
-
PTAM7
12 Pages
-
PTDM6
8 Pages
-
PTAM6
13 Pages
-
PTDM5
10 Pages
-
PTAM5
13 Pages
-
PTAM4
9 Pages
-
PTAM2
16 Pages
-
PTAM27
9 Pages
-
PTM27
10 Pages
-
PTM29
10 Pages
-
AWS
5 Pages
-
PH68
19 Pages
-
PH58
21 Pages
-
PH36
21 Pages
-
PRDS7
22 Pages
-
PRAS7
18 Pages
-
PRDS6
23 Pages
-
PRAS6
19 Pages
-
PRAS4
8 Pages
-
PRDS3
16 Pages
-
PRDS2
21 Pages
-
PRDS5
28 Pages
-
PRAS5
25 Pages
-
PRAS4
8 Pages
-
PRDS3
21 Pages
-
PRAS3
19 Pages
-
PRDS2
26 Pages
-
PRAS2
22 Pages
-
PRAS5
25 Pages
-
PRAS4
8 Pages
-
PRDS3
21 Pages
-
PRAS3
19 Pages
-
PRDS1
13 Pages
-
PRAS1
12 Pages
-
PRAS29
15 Pages
-
PRAS27
16 Pages
-
PRAS26
13 Pages
-
PRAS20
12 Pages
-
PMIB3
7 Pages
-
PMIS3
8 Pages
-
posichron® EasyMount
6 Pages
-
PCRP32
18 Pages
-
PCST27
26 Pages
-
PCST25
27 Pages
-
PCST24
29 Pages
-
PCRP21
23 Pages
-
PCQA24
24 Pages
-
PCQA22
24 Pages
-
PCFP25
22 Pages
-
PCFP24
22 Pages
-
WB100M
21 Pages
-
WST 21
9 Pages
-
WB21
26 Pages
-
WST85
6 Pages
-
WB85
22 Pages
-
WST61
6 Pages
-
WB61
22 Pages
-
WB12
23 Pages
-
WB10ZG
20 Pages
-
WS7.0
6 Pages
-
LR19
6 Pages
-
WS12EX
8 Pages
-
WS10EX
8 Pages
-
WS58C
9 Pages
-
WS100M
24 Pages
-
WS60
12 Pages
-
WS7.5
41 Pages
-
WBT21
11 Pages
-
WS21
25 Pages
-
WBT61
7 Pages
-
WBT85
7 Pages
-
WS85
22 Pages
-
WS61
22 Pages
-
WS19KT
11 Pages
-
WS19KT
16 Pages
-
WS17KT
16 Pages
-
WS12
39 Pages
-
WS10
36 Pages
-
WS10ZG
36 Pages
-
WS10SG
36 Pages
-
WS42C
8 Pages
-
WS42
10 Pages
-
WS31C
8 Pages
-
WS31
10 Pages
-
PTM27
10 Pages
-
ASM Product Overview
40 Pages