Catalog excerpts
CASHCROFT Trust the shield.® Model T2 Pressure Transducer APPLICATIONS M12 Connection An affordable digitally compensated instrument for general industrial applications. • Process Automation • Compressor Control • Hydraulic Systems • Engine Monitoring • Pump Control • Pneumatics • Refrigeration Equipment • Presses • Machine Tools • Other General Industrial Applications FEATURES • 0.25% accuracy class • Ranges 30 psi through 20,000 psi • -40 to +125°C temperature capability • All welded pressure construction • Proven polysilicon thin film sensor • Precision ASIC based electronics • High EMI/RFI immunity rating • Highly configurable • Voltage and current outputs • Choice of electrical connections The T2 employs a polysilicon thin film sensor with a proven long term stability. The sensor is electron beam welded to a stainless steel pressure fitting to ensure high overpressure ratings and integrity in high shock, vibration and pressure cycling applications. Through the use of a high performance ASIC and modern digital compensation techniques the T2 provides extraordinary performance over temperature. The graph that follows depicts the performance over temperature on a Total Error Band basis - the Total Error Band includes not only temperature effects but also nonlinearity, hysteresis and non-repeatability. PERFORMANCE SPECIFICATIONS Ref. Temperature, 21°C ±1°C (70°F, ±2°F) Accuracy: Static Accuracy Class: ±0.25% of span (BFSL Method) including non-linearity, hysteresis, nonrepeatability at reference temperature Temperature Effect: -20°C to 85°C <±1% of Span - Total Error Band -40°C to -20°C <±1.5% of Span - Total Error Band -85°C to 125°C <±1.5% of Span - Total Error Band Total Error Band includes the combined effects of non-linearity (Terminal Point Method), hysteresis, non-repeatability, temperatureand zero offset and span setting errors. For higher performance availability consult factory Stability: Less than ±0.25% span/year Durability: Tested to 50 million cycles ENVIRONMENTAL SPECIFICATIONS Temperature: Compensated -40 to 125°C (-40 to 257°F) Humidity: 0 to 100% R.H., no effect Select from over 25 pressure ranges starting at 30 psi and running through 20,000 psi. Compound (vacuum & pressure) ranges are also available, see below. Overpressure (F.S.): Proof Burst Vibration: Random vibration (20 g) over temperature range (-40° to 125°C). Exceeds typical MlL. STD. requirements Shock: 100gs, 6 ms Drop Test: Withstands 1 meter on concrete 3 axis Response Time: Less than 1 msec Warm-up Time: Less than 500 msec typical Position Effect: Less than ±0.01% span, typical ELECTRICAL SPECIFICATIONS Output Signals Available: TOTAL ERROR BAND (TEB) Error limits of all points (0-100% of range) Ambient Temperature (C) □ Pos Error Limit Voltage Output Excitation Ratiometric Output 0.5-4.5 Vdc, 3 wire Current Output 4-20mA, 2 wire 9-36 Vdc Reverse Polarity & Miswired Protected: Yes Insulation Breakdown Voltage: 100 Vac Insulation Resistance: Greater than 100 megohms at 100 Vdc CE Compliance: Per EN 61326: 1997+ A1: 1998 + A2: 2001, Annex A (Heavy Industrial) All specifications are subject to change without notice. All sales subject to standard terms and conditions. © Ashcroft Inc. 2015 11/15 Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA Tel: 203-385-0648 • Fax: 203-385-0408 email: info@ashcroft.com •
Open the catalog to page 1Model T2 Pressure Transducer PHYSICAL SPECIFICATIONS Wetted Materials: 304SS pressure connection and 17-4PH SS sensor diaphragm Housing: 20% Glass Reinforced Nylon, Fire retardant to UL94 V1 Available Process Connections (Male): 1 ⁄8 NPT, 1⁄4 BSP, 1⁄4 NPT, G1⁄4 B, 7⁄16-20 UNF-2A For other connections consult factory Ingress Rating: Enclosure meets NEMA 4X, IP65 ELECTRICAL TERMINATION • Pigtail: 3 feet of shielded cable, PVC jacket, 24 AWG leads • EN 175301-803, Form A (DIN 43650, Form A) • Bendix style 4 pin, PTO 2A-8-4P or similar • M12 x 1, 4 pin, Circular style Power Supply Voltage vs....
Open the catalog to page 2All ASHCROFT catalogs and technical brochures
-
A4A Precision Pressure Gauge
4 Pages
-
1084 Test Gauge
2 Pages
-
1001T Panel Mount Gauge
4 Pages
-
1000 Commercial Gauge
2 Pages
-
Type 1339 Duplex Gauge
2 Pages
-
1038A Duplex Pressure Gauge
2 Pages
-
1220 Pressure Gauge
3 Pages
-
2008 Panel Pressure Gauge
4 Pages
-
1198 Finned Siphon
2 Pages
-
2198 MicroTube™ Siphon
3 Pages
-
1098 and 1100 Siphons
5 Pages
-
CI Bimetal Thermometer
2 Pages
-
EI Bimetal Thermometer
2 Pages
-
T6500 Pressure Gauge
5 Pages
-
T5500 Pressure Gauge
5 Pages
-
1109 Pressure Gauge
2 Pages
-
Acid Leak Detection (ALD)
4 Pages
-
5503
2 Pages
-
1209
3 Pages
-
1290
2 Pages
-
2462
2 Pages
-
Type 1133
2 Pages
-
Type 1127/1128
2 Pages
-
Model C-600A-03
2 Pages
-
Industry sanitary-pharm
4 Pages
-
302-303
4 Pages
-
T5500E
2 Pages
-
IXLDP
2 Pages
-
k1
2 Pages
-
K2
2 Pages
-
K8
2 Pages
-
km15
2 Pages
-
KS Sanitary
2 Pages
-
KX Transducers
2 Pages
-
RXLDP
2 Pages
-
SL17-TTS
1 Pages
-
SL 17 Submersible
2 Pages
-
600-01
2 Pages
-
600-02
2 Pages
-
600-03
2 Pages
-
600-04
2 Pages
-
600B
2 Pages
-
600H
2 Pages
-
ar10
4 Pages
-
ar20
4 Pages
-
at30 skin type thermocouple.
4 Pages
-
Type ST-2A Digital Indicator
2 Pages
-
Type 1305D Deadweight Tester
2 Pages
-
Model PT-1 Pressure Tester
2 Pages
-
ATE-2 Handheld Calibrator
12 Pages
-
SWGL
7 Pages
-
sw10
9 Pages
-
A N4
4 Pages
-
A series
8 Pages
-
600A
2 Pages
-
DT 600A
2 Pages
-
ash A4
2 Pages
-
A4
2 Pages
-
A2X
2 Pages
-
ASH DIG
3 Pages
-
DG 25
3 Pages
-
1008S
2 Pages
-
1008 A AL
2 Pages
-
1125
1 Pages
-
1009 1010
1 Pages
-
1010
2 Pages
-
test gauges
3 Pages
-
1259
2 Pages
-
Ash SW10
9 Pages
-
Ash SWA
8 Pages
-
Ash DG 25
3 Pages
-
Ash DG
2 Pages
-
Ash Bul
3 Pages
-
Ash EL
2 Pages
-
Ash BM
2 Pages
-
Ash A2x
2 Pages
-
Ash A2 1 3
2 Pages
Archived catalogs
-
Bimetal Thermometers - Series CI
8 Pages
-
Sanitary Gauges - Type 1032
4 Pages
-
Industrial Gauges Type 1017
24 Pages
-
Process Gauges Type 1279
16 Pages
-
Test Gauges Type 1082
12 Pages