Group: DRESSER FLOW CONTROL
Catalog excerpts
Pressure Transducer Capabilities hen “off the shelf” pressure transducers won't satisfy your requirements, contact Ashcroft Inc. and put our customization services to the test. With 160+ years of expertise in pressure measurement, expert engineering staff and state-of-the-art test facility, we have the capability to customize and verify sensors for the special requirements of your application. Custom Product Modifications Include: • Outputs (Analog & Digital) • Electrical Terminations • Pressure Fittings • Ranges/Units of Measure • Calibration • Circuit Boards • Enclosures • Process Protection/Isolation • Mounting • Product Labeling n addition to the standard products shown on our website and catalogs, we offer additional capabilities to meet the needs of the Original Equipment Manufacturer (OEM) – particularly in support of demanding applications found in market segments such as mobile hydraulics, railway/transportation, performance race, medical and HVAC (critical room monitoring and flow measurements). All specifications are subject to change without notice. All sales subject to standard terms and conditions. © 2013 Ashcroft Inc. 01/2013 Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA Tel: 203-385-0648 • Fax: 203-385-0408 email: info@ashcroft.com • www.ashcroft.com
Open the catalog to page 1Pressure Transducer Capabilities - Technology mploying the correct sensor technology Polysilicon CVD Thin Film Sensors; is critical, and is the starting point in • High Repeatability, <0.05% Span and serving challenging applications from a speciStability, <0.25% Span/year under fication and cost perspective, We have been operating conditions. developing and improving pressure sensing • Extreme Durability, tested to 50 million technology for over 30 years. pressure cycles. Rated for temperature ranges from -40° to +125°C (-40° to +257°F). • Hydraulic Transient Resistance, standard...
Open the catalog to page 2Pressure Transducer Capabilities - Design Our dedicated engineering team is receive the solution for your needs. • Technology Ownership, calibration and testing programs to meet specific performance objectives. • Electrical Engineering, providing both analog and digital output design capability. Addressing agency approval requirements • Mechanical Engineering, supporting the environmental packaging, pressure connection and electrical termination specifications with advanced computer aided analysis tools. • Software Engineering, supporting firmware design, embedded code and product...
Open the catalog to page 3Pressure Transducer Capabilities - Manufacturing ur in-house Design Validation and Product Test Lab allows for on-site industry standard and customized testing. • Vibration tables, 0 to 9500 Hz (including combined temperature environment) • Temperature testing from -100° to 350°F (-75° to 175°C) • Cycle testing from 0 to 10,000 psi (700 bar) • Burst pressure testing to 150,000 psi (10,300 bar) • Primary pressure standards from 0.06 IWC (15 Pa) to 100,000 psi (6,800 bar) • GTEM cell - tests immunity to radiated electromagnetic fields to 100 V/m from 80 MHz to 1GHz • EM clamp - tests immunity...
Open the catalog to page 4All ASHCROFT catalogs and technical brochures
-
A4A Precision Pressure Gauge
4 Pages
-
1084 Test Gauge
2 Pages
-
1001T Panel Mount Gauge
4 Pages
-
1000 Commercial Gauge
2 Pages
-
Type 1339 Duplex Gauge
2 Pages
-
1038A Duplex Pressure Gauge
2 Pages
-
1220 Pressure Gauge
3 Pages
-
2008 Panel Pressure Gauge
4 Pages
-
1198 Finned Siphon
2 Pages
-
2198 MicroTube™ Siphon
3 Pages
-
1098 and 1100 Siphons
5 Pages
-
CI Bimetal Thermometer
2 Pages
-
EI Bimetal Thermometer
2 Pages
-
T6500 Pressure Gauge
5 Pages
-
T5500 Pressure Gauge
5 Pages
-
1109 Pressure Gauge
2 Pages
-
Acid Leak Detection (ALD)
4 Pages
-
5503
2 Pages
-
1209
3 Pages
-
1290
2 Pages
-
2462
2 Pages
-
Type 1133
2 Pages
-
Type 1127/1128
2 Pages
-
Model C-600A-03
2 Pages
-
Industry sanitary-pharm
4 Pages
-
302-303
4 Pages
-
T5500E
2 Pages
-
IXLDP
2 Pages
-
k1
2 Pages
-
K2
2 Pages
-
K8
2 Pages
-
km15
2 Pages
-
KS Sanitary
2 Pages
-
KX Transducers
2 Pages
-
RXLDP
2 Pages
-
SL17-TTS
1 Pages
-
SL 17 Submersible
2 Pages
-
T2 Transducers
2 Pages
-
600-01
2 Pages
-
600-02
2 Pages
-
600-03
2 Pages
-
600-04
2 Pages
-
600B
2 Pages
-
600H
2 Pages
-
ar10
4 Pages
-
ar20
4 Pages
-
at30 skin type thermocouple.
4 Pages
-
Type ST-2A Digital Indicator
2 Pages
-
Type 1305D Deadweight Tester
2 Pages
-
Model PT-1 Pressure Tester
2 Pages
-
ATE-2 Handheld Calibrator
12 Pages
-
SWGL
7 Pages
-
sw10
9 Pages
-
A N4
4 Pages
-
A series
8 Pages
-
600A
2 Pages
-
DT 600A
2 Pages
-
ash A4
2 Pages
-
A4
2 Pages
-
A2X
2 Pages
-
ASH DIG
3 Pages
-
DG 25
3 Pages
-
1008S
2 Pages
-
1008 A AL
2 Pages
-
1125
1 Pages
-
1009 1010
1 Pages
-
1010
2 Pages
-
test gauges
3 Pages
-
1259
2 Pages
-
Ash SW10
9 Pages
-
Ash SWA
8 Pages
-
Ash DG 25
3 Pages
-
Ash DG
2 Pages
-
Ash Bul
3 Pages
-
Ash EL
2 Pages
-
Ash BM
2 Pages
-
Ash A2x
2 Pages
-
Ash A2 1 3
2 Pages
Archived catalogs
-
Bimetal Thermometers - Series CI
8 Pages
-
Sanitary Gauges - Type 1032
4 Pages
-
Industrial Gauges Type 1017
24 Pages
-
Process Gauges Type 1279
16 Pages
-
Test Gauges Type 1082
12 Pages