Catalog excerpts
C ASHCROFT' Trust the shield.™ APPLICATIONS: Pulp/paper, waste water, spray booths and all heavy medium and pumping processes FEATURES: • Available with PMC adapter (shown) • Flush-mounted integral 316 stainless steel diaphragm • Stainless steel NEMA 4X enclosure • Current/voltage output The Ashcroft® KX transmitter combines the proven benefits of poly-silicon thin film performance with the utility of a flushmounting sensing diaphragm. Modern low-pressure chemical vapor deposition methods provide simple, stable molecular bonds between the metal diaphragm and a polysilicon strain gage bridge. There are no epoxies or bonding agents to contribute to signal instability or drift. The flush sensing element is provided by an integral, silicone filled stainless steel diaphragm seal. The small sensing area and low internal volume ensure accurate measurement under severe conditions. The polysilicon strain resistors combine very low noise levels with very high signal output. The integral metal diaphragm and polysilicon bridge are virtually unaffected by shock, vibration or mounting position. These transmitters are offered in many standard pressure ranges with either current or voltage output signals. Transmitter performance is directly traceable to the National Institute of Standards and Technology. PERFORMANCE SPECIFICATIONS Accuracy Class (Span): ±1.0% Includes non-linearity, (Terminal Point Method), hysteresis, non-repeatability, zero offset and span setting errors Best fit straight line (BFSL) ±0.75% Includes non-linearity, hysteresis and nonrepeatability error ENVIRONMENTAL SPECIFICATIONS Temperature Storage -65/+250°F Thermal Coefficients: (68°F ref.) % Span/°F Standard: ZERO ±0.04% Humidity: No performance effect at 95% relative humidity - noncondensing FUNCTIONAL SPECIFICATIONS Standard Ranges (psi) 0/100 0/500 0/3000 Consult factory for nonstandard ranges. Overpressure: (F.S. psi) 0/100- 0/3000 Vibration Sweep: Less than ±0.1 %F.S. effect for 0-400 Hz at 20 g’s in any axis Shock: Less than ±0.1 %F.S. effect for 20 g’s 20ms shock in any axis ELECTRICAL SPECIFICATIONS Output Signal: 4-20mA (2 wire) 1-5 Vdc (3 wire) 1-6 Vdc (3 wire) Power Requirements: 10-36 Vdc unregulated Supply Current: Less than 3mA for voltage output Output Impedance: 100 ohms Circuit to Case Insulation Resistance: 100 M ohms @ 50 Vdc All specifications are subject to change without notice. All sales subject to standard terms and conditions. © Ashcroft Inc. 2015 10/15 Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA Tel: 203-378-8281 • Fax: 203-385-0408 email: info@ashcroft.com • www.ashcroft.com
Open the catalog to page 1C ASHCROFT' Trust the shield.™ Model KX Flush Mount Pressure Transducer PHYSICAL SPECIFICATIONS Enclosure: NEMA 4X Weight: 10 oz (approx. without cable) MATERIALS Case: 300 series stainless steel Connection: 316 stainless steel Cable: No. 24 AWG, 36" PVC, shielded, vented, UL approved Diaphragm: 316Ti stainless steel Standard Process Connections: G-J2 metric pipe thread* O-ring seal (max. 150 psi) J2 NPT male pipe thread used in conjunction with XWB, XWC and XWE screw-on adapters *Mating connection available upon request OPTIONS • (XWB) Flush weldnut • (XWC) Recessed weldnut • (XWD) Weldnut...
Open the catalog to page 2All ASHCROFT catalogs and technical brochures
-
A4A Precision Pressure Gauge
4 Pages
-
1084 Test Gauge
2 Pages
-
1001T Panel Mount Gauge
4 Pages
-
1000 Commercial Gauge
2 Pages
-
Type 1339 Duplex Gauge
2 Pages
-
1038A Duplex Pressure Gauge
2 Pages
-
1220 Pressure Gauge
3 Pages
-
2008 Panel Pressure Gauge
4 Pages
-
1198 Finned Siphon
2 Pages
-
2198 MicroTube™ Siphon
3 Pages
-
1098 and 1100 Siphons
5 Pages
-
CI Bimetal Thermometer
2 Pages
-
EI Bimetal Thermometer
2 Pages
-
T6500 Pressure Gauge
5 Pages
-
T5500 Pressure Gauge
5 Pages
-
1109 Pressure Gauge
2 Pages
-
Acid Leak Detection (ALD)
4 Pages
-
5503
2 Pages
-
1209
3 Pages
-
1290
2 Pages
-
2462
2 Pages
-
Type 1133
2 Pages
-
Type 1127/1128
2 Pages
-
Model C-600A-03
2 Pages
-
Industry sanitary-pharm
4 Pages
-
302-303
4 Pages
-
T5500E
2 Pages
-
IXLDP
2 Pages
-
k1
2 Pages
-
K2
2 Pages
-
K8
2 Pages
-
km15
2 Pages
-
KS Sanitary
2 Pages
-
RXLDP
2 Pages
-
SL17-TTS
1 Pages
-
SL 17 Submersible
2 Pages
-
T2 Transducers
2 Pages
-
600-01
2 Pages
-
600-02
2 Pages
-
600-03
2 Pages
-
600-04
2 Pages
-
600B
2 Pages
-
600H
2 Pages
-
ar10
4 Pages
-
ar20
4 Pages
-
at30 skin type thermocouple.
4 Pages
-
Type ST-2A Digital Indicator
2 Pages
-
Type 1305D Deadweight Tester
2 Pages
-
Model PT-1 Pressure Tester
2 Pages
-
ATE-2 Handheld Calibrator
12 Pages
-
SWGL
7 Pages
-
sw10
9 Pages
-
A N4
4 Pages
-
A series
8 Pages
-
600A
2 Pages
-
DT 600A
2 Pages
-
ash A4
2 Pages
-
A4
2 Pages
-
A2X
2 Pages
-
ASH DIG
3 Pages
-
DG 25
3 Pages
-
1008S
2 Pages
-
1008 A AL
2 Pages
-
1125
1 Pages
-
1009 1010
1 Pages
-
1010
2 Pages
-
test gauges
3 Pages
-
1259
2 Pages
-
Ash SW10
9 Pages
-
Ash SWA
8 Pages
-
Ash DG 25
3 Pages
-
Ash DG
2 Pages
-
Ash Bul
3 Pages
-
Ash EL
2 Pages
-
Ash BM
2 Pages
-
Ash A2x
2 Pages
-
Ash A2 1 3
2 Pages
Archived catalogs
-
Bimetal Thermometers - Series CI
8 Pages
-
Sanitary Gauges - Type 1032
4 Pages
-
Industrial Gauges Type 1017
24 Pages
-
Process Gauges Type 1279
16 Pages
-
Test Gauges Type 1082
12 Pages