IXLDP - 1

C ASHCROFT' Trust the shield.™ Model IXLdp Ultra-Low Differential Pressure Transmitter <FM> APPROVH) LOOK FOR THIS AGENCY MARK ON OUR PRODUCTS APPLICATIONS: HVAC, fume hood control, lab/clean room pressurization, laminar flow, furnace/stack draft, leak detection, or pollution monitoring, medical equipment, fan tracking, filter monitoring and velocity measurements FEATURES: • Certified 0.25% and 0.5% accuracy • 0.1"-200"-H2O pressure ranges • High overpressure protection • Optional FM approval for hazardous locations • NEMA 4X metal construction • Six types of output signals available • 5:1 turndown option • Variable dampening option • On-board voltage regulation allows use of lower cost, non-precise, unregulated power supply • Hazardous environments Featuring a highly reliable variable capacitance sensor using the patented Ashcroft® SiGlas™ sensor. This ultra-thin single crystal diaphragm provides inherent sensor repeatability and stability. PERFORMANCE SPECIFICATIONS Ref. Temperature: 70°F ±2°F (21°C ±1°C) Accuracy Class (of Span) Two Options: ±0.25%, ±0.5% Includes non-linearity (Terminal Point Method), hysteresis, non-repeatability, zero offset and span setting errors. Stability - Max. Change (Span/year): ±0.25 Standard Ranges (Inches W.C.) Unidirectional Ranges: Custom Ranges: Special range calibrations - see options Response Time: Standard: 250ms Optional variable damping (0-30 sec) - see options ENVIRONMENTAL SPECIFICATIONS Temperature Limits: Storage: -40 to 210°F Vibration Sweep: Less than 0.2% Span/g temporary effect 10-130 Hz The Ashcroft® Industrial IXLdp was designed for the measurement and control of very low pressure and flow in industrial and process plant environments. The Industrial IXLdp transmitter features a rugged NEMA 4X enclosure, built-in electrical terminal box isolated from the electronics and threaded process connections. The Ashcroft IXLdp transmitter utilizes a state-of-the-art variable capacitance sensor with a glass-clad silicon chip. The Si-GlasTM technology combines the high sensitivity of a variable capacitance transducer with the repeatability of a micro-machined, single-crystal silicon diaphragm. The Si-Glas sensor is composed of sputtered metals and glass molecularly bonded to silicon. There are no epoxies or other organics in the sensor to contribute to drift or mechanical degradation over time. All specifications are subject to change without notice. All sales subject to standard terms and conditions. BULLETIN CT-3 © Ashcroft Inc. 2015 10/15 FUNCTIONAL SPECIFICATIONS Overpressure Limits: Proof differential pressure: 20 psid Burst differential pressure: 50 psid Maximum static (line) pressure: 100 psi Static pressure effect: less than 0.5% Span Mounting Position Effect: 1" W.C. and higher 0.1% Span/g 0.25" up to 0.5” W.C. 0.5% Span/g 0.1" W.C. 0.8% Span/g Note: Calibrated horizontally standard unless otherwise specified. Mounting Position Effect easily corrected with zero potentiometer. ELECTRICAL SPECIFICATIONS Output Signal: Power: Output Signal is Independent of Power Supply Changes: 12-36 Vdc range without effect on output signal Reverse Wiring Protected Internal Zero and Span: ±10% F.S. Adjustment Supply Current: 2.6mA typical for voltage output (Continued on other side} Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA Tel: 203-378-8281 • Fax: 203-385-0408 email: info@ashcroft.com •

Open the catalog to page 1
IXLDP - 2

C ASHCROFT' Trust the shield.™ Warm-up Time: Full specification: Less than one second Fast Response, Turndown & Variable Dampening Optional PHYSICAL SPECIFICATIONS Enclosure: NEMA 4X, 300 series stainless steel Process Connections: Two >4 NPT female Electrical Connections: Two >2" female electrical conduit connections isolated from the electronics. Separate access cover for terminal connections Media: Clean, dry and noncorrosive gas (consult factory for use on other media) NOT FOR USE ON LIQUIDS Load Limitations 4-20mA Output Only Loop Supply Voltage (VDC) Vmin = 12V+ (.022A x Rl) Rl =...

Open the catalog to page 2

All ASHCROFT catalogs and technical brochures

  1. 5503

    2 Pages

  2. 1209

    3 Pages

  3. 1290

    2 Pages

  4. 2462

    2 Pages

  5. Type 1133

    2 Pages

  6. 302-303

    4 Pages

  7. T5500E

    2 Pages

  8. k1

    2 Pages

  9. K2

    2 Pages

  10. K8

    2 Pages

  11. km15

    2 Pages

  12. KS Sanitary

    2 Pages

  13. RXLDP

    2 Pages

  14. SL17-TTS

    1 Pages

  15. 600-01

    2 Pages

  16. 600-02

    2 Pages

  17. 600-03

    2 Pages

  18. 600-04

    2 Pages

  19. 600B

    2 Pages

  20. 600H

    2 Pages

  21. ar10

    4 Pages

  22. ar20

    4 Pages

  23. SWGL

    7 Pages

  24. sw10

    9 Pages

  25. A N4

    4 Pages

  26. A series

    8 Pages

  27. 600A

    2 Pages

  28. DT 600A

    2 Pages

  29. ash A4

    2 Pages

  30. A4

    2 Pages

  31. A2X

    2 Pages

  32. ASH DIG

    3 Pages

  33. DG 25

    3 Pages

  34. 1008S

    2 Pages

  35. 1008 A AL

    2 Pages

  36. 1125

    1 Pages

  37. 1009 1010

    1 Pages

  38. 1010

    2 Pages

  39. test gauges

    3 Pages

  40. 1259

    2 Pages

  41. Ash SW10

    9 Pages

  42. Ash SWA

    8 Pages

  43. Ash DG 25

    3 Pages

  44. Ash DG

    2 Pages

  45. Ash Bul

    3 Pages

  46. Ash EL

    2 Pages

  47. Ash BM

    2 Pages

  48. Ash A2x

    2 Pages

  49. Ash A2 1 3

    2 Pages

Archived catalogs