Catalog excerpts
C ASHCROFT' Trust the shield.™ Model IXLdp Ultra-Low Differential Pressure Transmitter <FM> APPROVH) LOOK FOR THIS AGENCY MARK ON OUR PRODUCTS APPLICATIONS: HVAC, fume hood control, lab/clean room pressurization, laminar flow, furnace/stack draft, leak detection, or pollution monitoring, medical equipment, fan tracking, filter monitoring and velocity measurements FEATURES: • Certified 0.25% and 0.5% accuracy • 0.1"-200"-H2O pressure ranges • High overpressure protection • Optional FM approval for hazardous locations • NEMA 4X metal construction • Six types of output signals available • 5:1 turndown option • Variable dampening option • On-board voltage regulation allows use of lower cost, non-precise, unregulated power supply • Hazardous environments Featuring a highly reliable variable capacitance sensor using the patented Ashcroft® SiGlas™ sensor. This ultra-thin single crystal diaphragm provides inherent sensor repeatability and stability. PERFORMANCE SPECIFICATIONS Ref. Temperature: 70°F ±2°F (21°C ±1°C) Accuracy Class (of Span) Two Options: ±0.25%, ±0.5% Includes non-linearity (Terminal Point Method), hysteresis, non-repeatability, zero offset and span setting errors. Stability - Max. Change (Span/year): ±0.25 Standard Ranges (Inches W.C.) Unidirectional Ranges: Custom Ranges: Special range calibrations - see options Response Time: Standard: 250ms Optional variable damping (0-30 sec) - see options ENVIRONMENTAL SPECIFICATIONS Temperature Limits: Storage: -40 to 210°F Vibration Sweep: Less than 0.2% Span/g temporary effect 10-130 Hz The Ashcroft® Industrial IXLdp was designed for the measurement and control of very low pressure and flow in industrial and process plant environments. The Industrial IXLdp transmitter features a rugged NEMA 4X enclosure, built-in electrical terminal box isolated from the electronics and threaded process connections. The Ashcroft IXLdp transmitter utilizes a state-of-the-art variable capacitance sensor with a glass-clad silicon chip. The Si-GlasTM technology combines the high sensitivity of a variable capacitance transducer with the repeatability of a micro-machined, single-crystal silicon diaphragm. The Si-Glas sensor is composed of sputtered metals and glass molecularly bonded to silicon. There are no epoxies or other organics in the sensor to contribute to drift or mechanical degradation over time. All specifications are subject to change without notice. All sales subject to standard terms and conditions. BULLETIN CT-3 © Ashcroft Inc. 2015 10/15 FUNCTIONAL SPECIFICATIONS Overpressure Limits: Proof differential pressure: 20 psid Burst differential pressure: 50 psid Maximum static (line) pressure: 100 psi Static pressure effect: less than 0.5% Span Mounting Position Effect: 1" W.C. and higher 0.1% Span/g 0.25" up to 0.5” W.C. 0.5% Span/g 0.1" W.C. 0.8% Span/g Note: Calibrated horizontally standard unless otherwise specified. Mounting Position Effect easily corrected with zero potentiometer. ELECTRICAL SPECIFICATIONS Output Signal: Power: Output Signal is Independent of Power Supply Changes: 12-36 Vdc range without effect on output signal Reverse Wiring Protected Internal Zero and Span: ±10% F.S. Adjustment Supply Current: 2.6mA typical for voltage output (Continued on other side} Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA Tel: 203-378-8281 • Fax: 203-385-0408 email: info@ashcroft.com •
Open the catalog to page 1C ASHCROFT' Trust the shield.™ Warm-up Time: Full specification: Less than one second Fast Response, Turndown & Variable Dampening Optional PHYSICAL SPECIFICATIONS Enclosure: NEMA 4X, 300 series stainless steel Process Connections: Two >4 NPT female Electrical Connections: Two >2" female electrical conduit connections isolated from the electronics. Separate access cover for terminal connections Media: Clean, dry and noncorrosive gas (consult factory for use on other media) NOT FOR USE ON LIQUIDS Load Limitations 4-20mA Output Only Loop Supply Voltage (VDC) Vmin = 12V+ (.022A x Rl) Rl =...
Open the catalog to page 2All ASHCROFT catalogs and technical brochures
-
A4A Precision Pressure Gauge
4 Pages
-
1084 Test Gauge
2 Pages
-
1001T Panel Mount Gauge
4 Pages
-
1000 Commercial Gauge
2 Pages
-
Type 1339 Duplex Gauge
2 Pages
-
1038A Duplex Pressure Gauge
2 Pages
-
1220 Pressure Gauge
3 Pages
-
2008 Panel Pressure Gauge
4 Pages
-
1198 Finned Siphon
2 Pages
-
2198 MicroTube™ Siphon
3 Pages
-
1098 and 1100 Siphons
5 Pages
-
CI Bimetal Thermometer
2 Pages
-
EI Bimetal Thermometer
2 Pages
-
T6500 Pressure Gauge
5 Pages
-
T5500 Pressure Gauge
5 Pages
-
1109 Pressure Gauge
2 Pages
-
Acid Leak Detection (ALD)
4 Pages
-
5503
2 Pages
-
1209
3 Pages
-
1290
2 Pages
-
2462
2 Pages
-
Type 1133
2 Pages
-
Type 1127/1128
2 Pages
-
Model C-600A-03
2 Pages
-
Industry sanitary-pharm
4 Pages
-
302-303
4 Pages
-
T5500E
2 Pages
-
k1
2 Pages
-
K2
2 Pages
-
K8
2 Pages
-
km15
2 Pages
-
KS Sanitary
2 Pages
-
KX Transducers
2 Pages
-
RXLDP
2 Pages
-
SL17-TTS
1 Pages
-
SL 17 Submersible
2 Pages
-
T2 Transducers
2 Pages
-
600-01
2 Pages
-
600-02
2 Pages
-
600-03
2 Pages
-
600-04
2 Pages
-
600B
2 Pages
-
600H
2 Pages
-
ar10
4 Pages
-
ar20
4 Pages
-
at30 skin type thermocouple.
4 Pages
-
Type ST-2A Digital Indicator
2 Pages
-
Type 1305D Deadweight Tester
2 Pages
-
Model PT-1 Pressure Tester
2 Pages
-
ATE-2 Handheld Calibrator
12 Pages
-
SWGL
7 Pages
-
sw10
9 Pages
-
A N4
4 Pages
-
A series
8 Pages
-
600A
2 Pages
-
DT 600A
2 Pages
-
ash A4
2 Pages
-
A4
2 Pages
-
A2X
2 Pages
-
ASH DIG
3 Pages
-
DG 25
3 Pages
-
1008S
2 Pages
-
1008 A AL
2 Pages
-
1125
1 Pages
-
1009 1010
1 Pages
-
1010
2 Pages
-
test gauges
3 Pages
-
1259
2 Pages
-
Ash SW10
9 Pages
-
Ash SWA
8 Pages
-
Ash DG 25
3 Pages
-
Ash DG
2 Pages
-
Ash Bul
3 Pages
-
Ash EL
2 Pages
-
Ash BM
2 Pages
-
Ash A2x
2 Pages
-
Ash A2 1 3
2 Pages
Archived catalogs
-
Bimetal Thermometers - Series CI
8 Pages
-
Sanitary Gauges - Type 1032
4 Pages
-
Industrial Gauges Type 1017
24 Pages
-
Process Gauges Type 1279
16 Pages
-
Test Gauges Type 1082
12 Pages