B-Series Switches - Pressure, Differential Pressure, Temperature & Hydraulic B-Series switches have proven reliable in such harsh environments as: • Chemical and petrochemical plants • Pulp and paper mills • Steel mills • Power plants • Water and sewage-treatment plants • Other corrosive environments Ashcroft Inc. supplies highly reliable Ashcroft® switches and controls for indus- trial and process applications. We begin with rock-solid designs, matching the most appropriate technology with the safety and reliability requirements of the applications. The materials of construction are specified to Ashcroft's exacting standards, and prod- uct is built to last in the toughest applica- tions. Our modern, responsive manufactur- ing facility is supported by an extensive network of stocking distributors and factory sales offices located in virtually every part of the world. Special application assistance is always just a telephone call away. The Ashcroft B-Series switch line is designed to satisfy most switch require- ments. Materials of construction have been selected for long life. A wide variety of pre- cision switch elements are available to meet every application requirement, including hermetically sealed contacts for added reliability and safety. The actuators we use have been proven in more than 20 years of service in the world's plants and mills. Special designs are available for fire safety, NACE, limit control and other more stringent requirements. Simplicity and ease of use are stressed to improve relia- Applications include: pumps, compres- sors, washers, filters, degreasers, evapora- tors, recovery systems, food processing, ground support equipment, reverse osmo- sis systems, heat exchangers, hydraulic systems, lubrication systems, marine equipment, textile machinery, heating and Thermowells must be used on any appli- cation where the stem of the temperature switch may be exposed to pressure, cor- rosive fluids or high velocity. Additionally the use of a thermowell permits instrument interchange or calibration check without disturbing or closing down the process. Ashcroft temperature switches have bulb diameters to match %" nominal bore thermowells. The bulbs have a sensitive portion length of 2" which can be used with 21/2""U" dimensioned thermowells or longer. For maximum accuracy, a thermo- well's "U" dimension should be selected to permit complete immersion of the sen- sitive portion plus 1" when measuring the temperature of liquids; an extra 3" should be allowed when measuring the temper- Thermowell bushings should be used with remote mount temperature switches. We recommend the standard 3" bulb and code 69 Series bushings for use with any thermowell "U" dimension. A split rubber grommet allows easy installation and "S" dimension adjustment. REGISTERED FIRM All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA email: ¡nfo@ashcroft.com • www.ashcroft.com
Open the catalog to page 1B-Series Switches - Pressure, Differential Pressure, Temperature & Hydraulic Temperature Switches B-Series temperature switches feature a SAMA Class II vapor pressure thermal system. This system provides quick, accurate response to process tempera- ture changes with negligible ambient temperature effects. This is inherent in the design due to the precise relation- ship that exists between temperature and pressure according to the vapor pressure laws. A wide selection of sensing bulb and armored capillary lengths is avail- able. The vapor pressure system design features small bulb sizes,...
Open the catalog to page 2B-Series Switches - Pressure, Differential Temperature & Hydraulic Pressure & Differential Pressure Switches B-Series pressure, differential pressure and vacuum switches use two different actuators depending on setpoint require-ments. For set- points between 2 and 3000 psi, the simple, rugged diaphragm-sealed piston actuator is used. This design features high reliability and choice of actuator seal materials for virtually every application. An optional welded design is also available for setpoints up to 1000 psi for All standard models feature ±1 percent of range setpoint repeatability and...
Open the catalog to page 3B-Series Switches - Pressure, Differential Pressure, Temperature & Hydraulic B-SERIES PRESSURE AND DIFFERENTIAL PRESSURE SWITCH MODEL NUMBER: To specify the exact switch desired, select entries from appropriate tables as shown in example below. Use table from page 6 Select from table on page 4 2 Not available with psid ranges. 3 Dual switches are 2 SPDT snap-action switches, not independently 4 Wires cannot be terminated inside B400 switch enclosure. 5 Not available with type 700 enclosure. 7 Estimated dc rating, 0.4A, 120 Vdc (not UL listed). 8 Available on pressure only. 9 Ambient...
Open the catalog to page 4B-Series Switches - Pressure, Differential Pressure, Temperature & Hydraulic B-SERIES TEMPERATURE SWITCH MODEL NUMBER: To specify the exact switch desired, select entries from appropriate tables as shown in example below. 3 - THERMAL SYSTEM SELECTION Direct Mount Order Code System Material Remote Mount 4 - BULB LENGTH SELECTION RANGE SELECTION 2 Available with remote mount thermal systems only. 3 Dual switches are 2 SPDT snap-action switches, not independently 4 Wires cannot be terminated inside T400 switch enclosure. 5 Not available with Type 700 enclosure. 6 Estimated dc rating, 2.5A, 28...
Open the catalog to page 5B-Series Switches - Pressure, Differential Pressure, Temperature & Hydraulic B-SERIES HYDRAULIC PRESSURE SWITCH MODEL NUMBER: To specify the exact switch desired, select entries from appropriate tables as shown in example below. Hydraulic pressure switch, Type 400, watertight Use table from page 7 PRESSURE RANGE 2 Dual switches are 2 SPDT snap-action switches, not independently adjustable. 3 Estimated dc rating, 0.4A, 120 Vdc (not UL listed). 4 Ambient operating temperature limits -20 to 150°F, all styles, setpoint shift of ±1% of range per 50°F temperature change is normal. Switches are...
Open the catalog to page 6All ASHCROFT catalogs and technical brochures
-
A4A Precision Pressure Gauge
4 Pages
-
1084 Test Gauge
2 Pages
-
1001T Panel Mount Gauge
4 Pages
-
1000 Commercial Gauge
2 Pages
-
Type 1339 Duplex Gauge
2 Pages
-
1038A Duplex Pressure Gauge
2 Pages
-
1220 Pressure Gauge
3 Pages
-
2008 Panel Pressure Gauge
4 Pages
-
1198 Finned Siphon
2 Pages
-
2198 MicroTube™ Siphon
3 Pages
-
1098 and 1100 Siphons
5 Pages
-
CI Bimetal Thermometer
2 Pages
-
EI Bimetal Thermometer
2 Pages
-
T6500 Pressure Gauge
5 Pages
-
T5500 Pressure Gauge
5 Pages
-
1109 Pressure Gauge
2 Pages
-
Acid Leak Detection (ALD)
4 Pages
-
5503
2 Pages
-
1209
3 Pages
-
1290
2 Pages
-
2462
2 Pages
-
Type 1133
2 Pages
-
Type 1127/1128
2 Pages
-
Model C-600A-03
2 Pages
-
Industry sanitary-pharm
4 Pages
-
302-303
4 Pages
-
T5500E
2 Pages
-
IXLDP
2 Pages
-
k1
2 Pages
-
K2
2 Pages
-
K8
2 Pages
-
km15
2 Pages
-
KS Sanitary
2 Pages
-
KX Transducers
2 Pages
-
RXLDP
2 Pages
-
SL17-TTS
1 Pages
-
SL 17 Submersible
2 Pages
-
T2 Transducers
2 Pages
-
600-01
2 Pages
-
600-02
2 Pages
-
600-03
2 Pages
-
600-04
2 Pages
-
600B
2 Pages
-
600H
2 Pages
-
ar10
4 Pages
-
ar20
4 Pages
-
at30 skin type thermocouple.
4 Pages
-
Type ST-2A Digital Indicator
2 Pages
-
Type 1305D Deadweight Tester
2 Pages
-
Model PT-1 Pressure Tester
2 Pages
-
ATE-2 Handheld Calibrator
12 Pages
-
SWGL
7 Pages
-
sw10
9 Pages
-
A N4
4 Pages
-
A series
8 Pages
-
600A
2 Pages
-
DT 600A
2 Pages
-
ash A4
2 Pages
-
A4
2 Pages
-
A2X
2 Pages
-
ASH DIG
3 Pages
-
DG 25
3 Pages
-
1008S
2 Pages
-
1008 A AL
2 Pages
-
1125
1 Pages
-
1009 1010
1 Pages
-
1010
2 Pages
-
test gauges
3 Pages
-
1259
2 Pages
-
Ash SWA
8 Pages
-
Ash DG 25
3 Pages
-
Ash DG
2 Pages
-
Ash Bul
3 Pages
-
Ash EL
2 Pages
-
Ash BM
2 Pages
-
Ash A2x
2 Pages
-
Ash A2 1 3
2 Pages
Archived catalogs
-
Bimetal Thermometers - Series CI
8 Pages
-
Sanitary Gauges - Type 1032
4 Pages
-
Industrial Gauges Type 1017
24 Pages
-
Process Gauges Type 1279
16 Pages
-
Test Gauges Type 1082
12 Pages