

Catalog excerpts

Model A2X Explosion/Flame Proof Pressure Transmitter APPLICATIONS: Oil field equipment, upstream oil and gas production, natural gas compression and transfer control, alternative energy projects FEATURES: • FM, cUL and ATEX listed • Choice of 0.25, 0.50 or 1.0% accuracy • Pressure ranges from 5 psi through 10,000 psi • CE mark • 316L SS wetted materials, 17-4 PH optional • 304 SS case • Six output signals to choose from • Optional absolute pressure ranges available LOOK FOR THESE MARKS ON OUR PRODUCTS The Ashcroft® A2X pressure transmitter is ideal for a broad spectrum of pressure sensing requirements requiring approvals for explosion/flame proof. The Ashcroft® A2X is designed and manufactured to provide the user with accurate, reliable, and stable output data. This is accomplished through the use of an on board microprocessor, that is programmed during a unique digital compensation process, to provide extremely linear and precise performance over the entire specified pressure and temperature range. PERFORMANCE SPECIFICATIONS Reference temperature 70°F (21°C) Accuracy, Three Classes (% Span): ±.25 ±0.5 ±1.0 Includes non-linearity (Terminal Point Method), hysteresis, non-repeatability, zero offset and span setting errors Best Fit Straight Line* (BFSL): ±.20 ±.40 ±.50 Includes non-linearity hysteresis, non-repeatability errors *Add ±.05% for ranges above 5000 psi Stability: ͨ ±0.25% Span/year @ reference conditions Durability: Greater than 10 million cycles ENVIRONMENTAL SPECIFICATIONS Temperature Limits: Storage: –40 to +125°C Process: –40 to +125°C Operating: –40 to +125°C Compensated*:–20 to +85°C (–40 to 257°F) (–40 to 257°F) (–40 to 257°F) ( –4 to 185°F) Temperature Effects: –20 to +85°C (–4 to 185°F) • 1.0% of Span for .25% Accuracy Class • 2.0% of Span for .50% and 1.0% Accuracy Classes Humidity Effects: No performance effects from 0 to 95% relative humidity, non-condensing, 0-100% RH with “W” enclosure. *Consult factory FUNCTIONAL SPECIFICATIONS Respone Time: <2ms Pressure Ranges: Vacuum, gauge, compound and absolute pressure from 0-5 psi through 0-10,000. Equivalent ranges in bar available. See order guide section (reverse.) Vibration Effect: 100g Peak, 11ms Shock: 10g RMS, 20-2000Hz Random: Sweep: 50-2000Hz, 5g peak Position Effect: ± 0.02% Typical CE Mark (standard): EN 61326:1997 + A1: 1998 Annex A Heavy Industrial Immunity (Annex A, Table A.1) Light Industrial/Residential Emission (Table 4) Overpressure (F.S.)*: Proof Burst 1.5 x F.S. min. 2 x F.S. 0#/vac. to 300 psi 1.2 x F.S. 1.5 x F.S. 500-10,000 psi *For higher overpressure ratings use XK8 option. See page 2 for additional option. ELECTRICAL SPECIFICATIONS Output Signal: Supply Voltage: (unregulated) Minimum Maximum (3 Wire) 12Vdc 36Vdc (3 Wire) 14Vdc 36Vdc (3 Wire) 10Vdc 36Vdc (3 Wire) 10Vdc 36Vdc (2 Wire) 12Vdc 36Vdc* (3 Wire) 4.5Vdc 5.5Vdc 0-5Vdc 0-10Vdc 1-5Vdc 1-6Vdc 4-20mA 0.5-4.5 Ratiometric *30Vdc max for Intrinsically Safe installations Power Requirements: Supply Current: <5mA for voltage outputs Electrical Termination: 1/2 NPT male conduit with flying leads or shielded cable Circuit Protection: Reverse polarity and mis-wire proected Insulation Resisance (Circuit to Case): 100Mohm @ 30Vdc PHYSICAL SPECIFICATIONS Case: Material 304SS Wetted Materials: 316L SS diaphragm and presure port, optional 17-4PH SS diaphragm and 316L SS pressure port (see How to Order Section). Ingress Protection Rating: IP65; NEMA 7,9 HAZARDOUS AREA CERTIFICATIONS Explosion Proof – cUL (USL/CNL): Specify A2X Class I, Div. 1 & 2, Groups A, B, C and D Class II, Div. 1 & 2, Groups E, F and G Flame Proof – ATEX: Specify A2X II 2 G Ex d IIC T4 NOTE: For 4-20mA units following approvals also apply: Intrinsically Safe – FM/CSA: Class I, Div. 1 Class I, Div. 2, Non-Incendive Refer to Ashcroft drawing #825A022 for wiring and installation requirements. NOTE: *Consult factory for other options BULLETIN A2X-1 Refer to Ashcroft Model A2 for Heavy Industrial, non-Hazardous rated configurations and Ashcroft Model A4 for Intrinsically Safe/non-Incendive applications. All specifications are subject to change without notice. All sales subject to standard terms and conditions. © 2012 Ashcroft Inc., Rev. 07/12 Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA Tel: 203-385-0648 • Fax: 203-385-0408 email: info@ashcroft.com • www.ashcroft.com
Open the catalog to page 1
DIMENSIONS dimensions in ( ) are mm Model A2X Explosion/Flame Proof Pressure Transmitter .887˝ (22.5) .887˝ (22.5) 4.78˝ (121) 4.78˝ (121) 3.065˝ (78) .675˝ (17) 3.065˝ (78) 1.06˝ (27) DIA. 1.06˝ (27) DIA. .885˝ (22) 1.06˝ (27) Hex. Common For All Pressure Fittings VdcMIN = 12V + (0.022A* X (RL) ) RL = RS+ RW RL = Loop Resistance (ohms) RS = Sense Resistance (ohms) RW = Wiring Resistance (ohms) * (Includes a 10% safety factor) EXPLOSION / FLAME PROOF ENCLOSURE XK8 OVERPRESSURE (F.S.) 0 to 2000 psi 3000 to 5000 psi 7500 to 10,000 psi Proof 200% 150% 120% Burst 800% 300% 150% NOTE: Refer to...
Open the catalog to page 2All ASHCROFT catalogs and technical brochures
-
1259 Process Gauge
4 Pages
-
A4A Precision Pressure Gauge
5 Pages
-
EL Bimetal Thermometer
4 Pages
-
A2 Pressure Transmitter
4 Pages
-
A4A Precision Pressure Gauge
4 Pages
-
1084 Test Gauge
2 Pages
-
1001T Panel Mount Gauge
4 Pages
-
1000 Commercial Gauge
2 Pages
-
Type 1339 Duplex Gauge
2 Pages
-
1038A Duplex Pressure Gauge
2 Pages
-
1220 Pressure Gauge
3 Pages
-
2008 Panel Pressure Gauge
4 Pages
-
1198 Finned Siphon
2 Pages
-
2198 MicroTube™ Siphon
3 Pages
-
1098 and 1100 Siphons
5 Pages
-
CI Bimetal Thermometer
2 Pages
-
EI Bimetal Thermometer
2 Pages
-
T6500 Pressure Gauge
5 Pages
-
T5500 Pressure Gauge
5 Pages
-
1109 Pressure Gauge
2 Pages
-
Acid Leak Detection (ALD)
4 Pages
-
5503
2 Pages
-
1209
3 Pages
-
1290
2 Pages
-
2462
2 Pages
-
Type 1133
2 Pages
-
Type 1127/1128
2 Pages
-
Model C-600A-03
2 Pages
-
Industry sanitary-pharm
4 Pages
-
302-303
4 Pages
-
T5500E
2 Pages
-
IXLDP
2 Pages
-
k1
2 Pages
-
K2
2 Pages
-
K8
2 Pages
-
km15
2 Pages
-
KS Sanitary
2 Pages
-
KX Transducers
2 Pages
-
RXLDP
2 Pages
-
SL17-TTS
1 Pages
-
SL 17 Submersible
2 Pages
-
T2 Transducers
2 Pages
-
600-01
2 Pages
-
600-02
2 Pages
-
600-03
2 Pages
-
600-04
2 Pages
-
600B
2 Pages
-
600H
2 Pages
-
ar10
4 Pages
-
ar20
4 Pages
-
at30 skin type thermocouple.
4 Pages
-
Type ST-2A Digital Indicator
2 Pages
-
Type 1305D Deadweight Tester
2 Pages
-
Model PT-1 Pressure Tester
2 Pages
-
ATE-2 Handheld Calibrator
12 Pages
-
SWGL
7 Pages
-
sw10
9 Pages
-
A N4
4 Pages
-
A series
8 Pages
-
600A
2 Pages
-
DT 600A
2 Pages
-
ash A4
2 Pages
-
A4
2 Pages
-
ASH DIG
3 Pages
-
DG 25
3 Pages
-
1008S
2 Pages
-
1008 A AL
2 Pages
-
1125
1 Pages
-
1009 1010
1 Pages
-
1010
2 Pages
-
Ash DG
2 Pages
Archived catalogs
-
Ash BM
2 Pages
-
Bimetal Thermometers - Series CI
8 Pages
-
Sanitary Gauges - Type 1032
4 Pages
-
Industrial Gauges Type 1017
24 Pages
-
Process Gauges Type 1279
16 Pages
-
Test Gauges Type 1082
12 Pages