1. Catalogs
  2. ASHCROFT
  3. A2 Pressure Transmitter
video corpo

A2 Pressure Transmitter
1 /4Pages

A2 Pressure Transmitter

A2 Pressure Transmitter
1 /4Pages

Catalog excerpts

A2 Pressure Transmitter-1

CASHCROFT Trust the shield.® A2 Pressure Transmitter FEATURES ■ Rugged housing ■ Highly configurable: wide selection of pressure ranges, pressure connections and electrical terminations ■ Output: select voltage or current versions ■ Available with externally adjustable zero and span access TYPICAL USES ■ Test stands ■ Pump and pneumatic systems control PERFORMANCE SPECIFICATIONS Reference Accuracy Class ±0.25%, ±0.5%, ±1.0% of span (Includes Terminal Point Method includes: hysteresis, non-linearity): non-repeatability, zero offset and span setting Pressure Transmitter Best Fit Straight ±0.2%, ±0.4%, ±0.5% of span Line (BFSL): Add ±0.05% for ranges >5,000 psi Durability: >10 million cycles Stability: <±0.25% span/year at reference conditions ENVIRONMENTAL SPECIFICATIONS Temperature -4 °F to 185 °F (-20 °C to 85 °C) Effects: ±1.0% of span for ±0.25% accuracy class ±2.0% of span for ±0.5% and ±1.0% accuracy class Humidity Effects: 0-95% R.H. non-condensing (no effects) 0-100% R.H. with welded enclosure (no effects) KEY BENEFITS• Provides the user with accurate, reliable, and stable output data• Board microprocessor provides extremely linear and precise performance over the entire pressure and temperature range ELECTRICAL SPECIFICATIONS FUNCTIONAL SPECIFICATIONS Response Time: <2ms Pressure Ranges: Vacuum, gauge, compound and absolute pressure from 0 to 5 psi through 0 to 10,000 psi (Bar ranges available) Sweep Vibration: 50-2,000Hz, 5g peak Position Effect: ±0.02%, typical Circuit Protection: Reverse polarity and mis-wire protected Insulation (Circuit Case): Output Signal: Supply Voltage: (unregulated) Min. Max. Overpressure: Proof: Burst: All specifications are subject to change without notice. All sales subject to standard terms and conditions. 1 of 4 Ashcroft® and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4PH®, Aminco®, Bendix® , Hirschmann®, VCR®, Tri-Clamp®. For more information, see Ashcroft Brands & Trademarks ©2024 Ashcroft Inc. a2_transducer_ds_RevH_10-24-24

 Open the catalog to page 1
A2 Pressure Transmitter-2

Data Sheet A2 Pressure Transmitter Electrical Terminations: See ordering code on page 3 for options LOAD LIMITATIONS 4-20 mA OUTPUT ONLY , Environmental Rating: WETTED MATERIAL Diaphragm Process Connection PHYSICAL SPECIFICATIONS Housing 304 Stainless steel VdcMin = 12V + (0.022A* X (RL)) RL = RS+ RW RL = Loop Resistance (ohms) RS = Sense Resistance (ohms) RW = Wiring Resistance (ohms) * (Includes a 10% safety factor) All specifications are subject to change without notice. All sales subject to standard terms and conditions. Ashcroft® and Trust the Shield® are trademarks of Ashcroft Inc. The...

 Open the catalog to page 2
A2 Pressure Transmitter-3

CASHCROFT Trust the shield.® A2 Pressure Transmitter ORDERING CODE Example: Pressure Connection F01 - Vs NPT Female M01 - 7s NPT Male M02 - 1/4 NPT Male M04 - 1/2 NPT Male VM2 - VCR® process connection 1/4" VCR® gland w/ 9/is-18 Male nut VF2 - VCR® process connection 1/4” VCR® gland w/ 9/is-18 Female nut S15 - Sanitary seal 11/2" Tri-Clamp® S20 - Sanitary seal 2" Tri-Clamp® Output Signal 16 - 1-6 Vdc 42 - 4-20 mA Electrical Termination Integral Cable (Pigtail) F2 - 3' shielded cable (available with enclosure code or S, Z) Pi - Specify length (available with enclosure code or S, Z) Hirschmann®...

 Open the catalog to page 3
A2 Pressure Transmitter-4

Data Sheet CASHCROFT Trust the shield.® DIMENSIONS in [ ] are millimeters For reference only, consult Ashcroft for specific dimensional drawings Heavy Industrial (Enclosure S, Z, Y, W) RANGE TABLE All specifications are subject to change without notice. All sales subject to standard terms and conditions. 4 of 4 Ashcroft® and Trust the Shield® are trademarks of Ashcroft Inc. The following non-Ashcroft trademarks are the property of their respective owners: 17-4PH®, Aminco®, Bendix® , Hirschmann®, VCR®, Tri-Clamp®. For more information, see Ashcroft Brands & Trademarks ©2024 Ashcroft Inc. a2_transducer_ds_RevH_10-24-24...

 Open the catalog to page 4

All ASHCROFT catalogs and technical brochures

  1. DG 25

    16  Pages

  2. 1008S

    4  Pages

  3. 5503

    2  Pages

  4. 1209

    3  Pages

  5. 1290

    2  Pages

  6. 2462

    2  Pages

  7. Type 1133

    2  Pages

  8. 302-303

    4  Pages

  9. T5500E

    2  Pages

  10. IXLDP

    2  Pages

  11. k1

    2  Pages

  12. K2

    2  Pages

  13. K8

    2  Pages

  14. km15

    2  Pages

  15. KS Sanitary

    2  Pages

  16. RXLDP

    2  Pages

  17. SL17-TTS

    1  Page

  18. 600-01

    2  Pages

  19. 600-02

    2  Pages

  20. 600-03

    2  Pages

  21. 600-04

    2  Pages

  22. 600B

    2  Pages

  23. 600H

    2  Pages

  24. ar10

    4  Pages

  25. ar20

    4  Pages

  26. SWGL

    7  Pages

  27. sw10

    9  Pages

  28. A N4

    4  Pages

  29. A series

    8  Pages

  30. 600A

    2  Pages

  31. DT 600A

    2  Pages

  32. ash A4

    2  Pages

  33. A4

    2  Pages

  34. A2X

    2  Pages

  35. ASH DIG

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.