Catalog excerpts
Data Sheet SASHCROFT Trust the shield.™ FEATURES ■ Compact size ■ 316 SS construction ■ Pressure ranges from vacuum to 15,000 psi ■ Factory set or field adjustable setpoints ■ Wide operating temperature range (-40°C to 100°C) ■ Precision snap-acting micro switch ■ SPDT or DPDT switching ■ UL, CSA listed models ■ CE and ROHS compliant ■ CRN models available (up to 10,000 psi) ■ SIL 3 capable TYPICAL USES ■ Offshore oil rigs ■ Chemical and petrochemical plants ■ Pulp and papermills ■ Autoclaves and sterilizers ■ Rail and heavy vehicles ■ Specialty machinery and equipment Setpoint: Single setpoint - Factory set or field adjustable Setpoint ±2% of span. For ranges 200 through 15,000 psi Repeatability: ±5% of span. For ranges -15/15 through 100 psi (additional setpoint shift ±2% of span per 40°F from initial setpoint setpoint at 70°F typical) Vibration: Passed Mil-STD-202G Shock: 75G’s 10 milliseconds 3 axis Piston: SS w/Viton or Buna-N O-ring Mechanical life >1,000,000 operations typical piston design: Diaphragm: 316L SS Mechanical life >400,000 operations typical diaphragm design: Switch Type: SPDT or DPDT Deadband: Fixed KEY BENEFITS • High performance • Small size • Special connections • Easily configurable to meet your application requirements • SIL 3 capable Enclosure Ratings: NEMA 6, IP67 Pressure % NPTF, / NPTF, / NPTM, % NPTM, % MNPT, Connection: % FNPT, 7A-20 SAE M, VCR, VCO, Tri-Clamp®, 1.5" Tri-Clover®, 2.0" Tri-Clover, G/ B, G/ A Type E Stub end Electrical output: SPDT, or DPDT 5A or 3A 120Vac, 2A @ 30Vdc, gold contacts available Approvals: UL, CSA, CE, CRN, SIL 3 capable, RoHS All specifications are subject to change without notice. All sales subject to standard terms and conditions. © 2019 Ashcroft Inc. awt_switch_ds_RevH_Ltr_02
Open the catalog to page 1CASHCROFT Trust the shield.™ A SERIES SWITCH PERFORMANCE CHARACTERISTICS RANGE (Ordering Code) SETPOINT REPEATABILITY SETPOINT ADJUSTABILITY All specifications are subject to change without notice. All sales subject to standard terms and conditions. © 2019 Ashcroft Inc. awt_switch_ds_RevH_Ltr_02-11-19 ashcroft.com info@ashcro
Open the catalog to page 2CASHCROFT Trust the shield.™ Ranges (See table on page 3 for additional ranges) 5 Characters maximum representing setpoint of the switch in the same units as the ranges of the switch. For setpoints in vacuum specify as “-” pressure. If no set point is required on an APA switch use either “NSR” or NSD”. If direction is not known use “NSR” as default Setpoint Direction R - Rising pressure (increasing pressure, decreasing vacuum) D - Decreasing pressure (decreasing pressure, increasing vacuum) Options - Select from table on page 3 (If choosing an option(s) must include an X’’) 6B - Cleaned for...
Open the catalog to page 3Data Sheet SASHCROFT Trust the shield.™ A-Series Miniature Watertight Pressure Switches DIMENSIONS For reference only, consult Ashcroft for specific dimensionaldrawings FUNCTION CODE MICRO SWITCH FIELD ADJUSTABLE PRESSURE CONNECTION GENERAL DIMENSION All specifications are subject to change without notice. All sales subject to standard terms and conditions. © 2019 Ashcroft Inc. awt_switch_ds_RevH_Ltr_02-11-19
Open the catalog to page 4Data Sheet A-Series Miniature Watertight Pressure Switches AVAILABLE CONNECTIONS Pressure Connections ½ NPT CONDUIT CONNECTOR WITH 18 AWG WIRE LEADS SPADE TERMINAL 4-0.187 MALE TERMINALS HIRSCHMANN MICRO-DIN CONNECTOR 43650 FORM C M20 X 1.5 MALE CONDUIT WITH 18 AWG WIRES ½ NPT MALE CONDUIT AND JACKETED CABLE WITH 18 AWG WIRES M20 X 1.5 MALE CONDUIT AND JACKETED CABLE WITH 18 AWG WIRES ⁄16-20 SAE MALE (OPTIONAL 37° FLARE END) Electrical Connections 5 of 7 All specifications are subject to change without notice. All sales subject to standard terms and conditions.
Open the catalog to page 5Data Sheet A-Series Miniature Watertight Pressure Switches SELECTION GUIDE Before selecting a switch the following should be considered: Actuator: The actuator responds to changes in pressure and operates the micro switch element in response to these changes. The actuator is normally exposed to the process media and must be chemically compatible with it. There are three types of actuators available for the A-Series switches – all welded 316 SS diaphragm sealed piston; 316 SS piston with Viton O-ring seal; and 316 SS piston with Buna-N O-ring seal. The 316 SS diaphragm is available in...
Open the catalog to page 6Data Sheet A-Series Miniature Watertight Pressure Switches ADDITIONAL SWITCH TERMINOLOGY Accuracy – (See repeatability) Accuracy normally refers to conformity of an indicated value to an accepted standard value. There is no indication in switch products; thus, instead, the term repeatability is used as the key performance measure. Automatic Reset Switch – Switch which returns to normal state when actuating variable Pressure is reduced. Adjustable or Operating Range – That part of the nominal range over which the switch setpoint may be adjusted. Normally about 10% to 100% of the nominal...
Open the catalog to page 7All ASHCROFT catalogs and technical brochures
-
A4A Precision Pressure Gauge
4 Pages
-
1084 Test Gauge
2 Pages
-
1001T Panel Mount Gauge
4 Pages
-
1000 Commercial Gauge
2 Pages
-
Type 1339 Duplex Gauge
2 Pages
-
1038A Duplex Pressure Gauge
2 Pages
-
1220 Pressure Gauge
3 Pages
-
2008 Panel Pressure Gauge
4 Pages
-
1198 Finned Siphon
2 Pages
-
2198 MicroTube™ Siphon
3 Pages
-
1098 and 1100 Siphons
5 Pages
-
CI Bimetal Thermometer
2 Pages
-
EI Bimetal Thermometer
2 Pages
-
T6500 Pressure Gauge
5 Pages
-
T5500 Pressure Gauge
5 Pages
-
1109 Pressure Gauge
2 Pages
-
Acid Leak Detection (ALD)
4 Pages
-
5503
2 Pages
-
1209
3 Pages
-
1290
2 Pages
-
2462
2 Pages
-
Type 1133
2 Pages
-
Type 1127/1128
2 Pages
-
Model C-600A-03
2 Pages
-
Industry sanitary-pharm
4 Pages
-
302-303
4 Pages
-
T5500E
2 Pages
-
IXLDP
2 Pages
-
k1
2 Pages
-
K2
2 Pages
-
K8
2 Pages
-
km15
2 Pages
-
KS Sanitary
2 Pages
-
KX Transducers
2 Pages
-
RXLDP
2 Pages
-
SL17-TTS
1 Pages
-
SL 17 Submersible
2 Pages
-
T2 Transducers
2 Pages
-
600-01
2 Pages
-
600-02
2 Pages
-
600-03
2 Pages
-
600-04
2 Pages
-
600B
2 Pages
-
600H
2 Pages
-
ar10
4 Pages
-
ar20
4 Pages
-
at30 skin type thermocouple.
4 Pages
-
Type ST-2A Digital Indicator
2 Pages
-
Type 1305D Deadweight Tester
2 Pages
-
Model PT-1 Pressure Tester
2 Pages
-
ATE-2 Handheld Calibrator
12 Pages
-
SWGL
7 Pages
-
sw10
9 Pages
-
A N4
4 Pages
-
A series
8 Pages
-
600A
2 Pages
-
DT 600A
2 Pages
-
ash A4
2 Pages
-
A4
2 Pages
-
A2X
2 Pages
-
ASH DIG
3 Pages
-
DG 25
3 Pages
-
1008S
2 Pages
-
1008 A AL
2 Pages
-
1125
1 Pages
-
1009 1010
1 Pages
-
1010
2 Pages
-
test gauges
3 Pages
-
1259
2 Pages
-
Ash SW10
9 Pages
-
Ash SWA
8 Pages
-
Ash DG 25
3 Pages
-
Ash DG
2 Pages
-
Ash Bul
3 Pages
-
Ash EL
2 Pages
-
Ash BM
2 Pages
-
Ash A2x
2 Pages
-
Ash A2 1 3
2 Pages
Archived catalogs
-
Bimetal Thermometers - Series CI
8 Pages
-
Sanitary Gauges - Type 1032
4 Pages
-
Industrial Gauges Type 1017
24 Pages
-
Process Gauges Type 1279
16 Pages
-
Test Gauges Type 1082
12 Pages