CASHCROFT Trust the shield.™ Model C-600A-01 Duratemp® Thermometer FEATURES • Exclusive movementless design resists shock and vibration - no gears to wear or misalign resulting in increased instrument life • Gas-operated molecular sieve • No elevation error • Mercury free • One bulb size for all ranges • ±1% full-span accuracy • Maxivision® dial • Limited five-year warranty A high impact-resistant polished stainless steel case. Bayonet ring facilitates easy removal for glass replacement and pointer adjustment. A versatile case that enables surface or flush mounting. Available in 412" dial size. Bulb Styles: Capillary Material: Line length: Armor: Ranges: -12" Bendable extension w/ A NPT union connection (B01) - Plain bulb with rigid extension no union (B03) - Plain bulb with rigid extension A NPT union on armor (B08) - 18' Bendable extension w/ A NPT union connection (B17) - 24" Bendable extension w/ A NPT union connection (B18) 300 Stainless steel 5 - 80 in standard increments (See table 5) AISI 302 Spring Armor standard, interlock 303 SS, PVC coated, plain and no armor are optional. -300/200°F-400/1200°F -200/100°C-200/650°C Dual scale ranges available 125% of span PRODUCT Model: Accuracy: Case Style: Dial Size: Window: Mounting and connection: Ambient Temperature: Bulb size: Bulb Material: SPECIFICATIONS C-600A-01 ±1% of span. Stainless steel, bayonet ring 4A" Maxivision linear anti-parallax dial black markings on a white dial Glass, shatterproof glass and plastic are optional. Surface/Lower (C01) or Flush/Rear (C11) 160°F/71°C 3" long by 3/8" O.D. 316 Stainless steel Over Range: Head/Elevation Error: None Product Options: Front Flange XFF (600A-01-C11 only) Dial Markings XDM Externally adjustable red set hand XEO Externally adjustable XEP Externally adjustable min. pointer XEQ Non-glare glass XNG Paper Tag XNN Stainless steel tag XNH Plastic Window XPD Shatterproof glass XSG Stationary Red Hand Set XSH CASE STYLE CASE STYLE MOUNTING CONNECTION Note: Thermowells must be used on any application where the bulb of the thermometer may be exposed to pressure, corrosive fluids, or velocity. Additionally, the use of a thermowell permits instrument interchangeability or recalibration without shutting down the process. All specifications are subject to change without notice. All sales subject to standard terms and conditions. © 2014 Ashcroft Inc. 0714 Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA Tel: 203-378-8281 • Fax: 203-385-0408 email: info@ashcroft.com • www.ash
Open the catalog to page 1C ASHCROFT' Trust the shield.™ Dial Size Inches NOTE: Dimensions in inches, ( ) are millimeters. sensitive Portion r -3/8 (10) Dia. B Sensitive Portion Bulb Code Style B03 13" plain bulb for applications used in open tanks where pressures and velocities are negligible. Armor Style A1 AISI 302 stainless steel spring armor is supplied as standard. Originally designed for U.S. Navy Hi Shock thermometers Style B08 The compression fitting fastens anywhere along the armored line. This bulb style is well suited for insertion requirements in excess of 1332". The B08 style is not a pressure tight...
Open the catalog to page 2All ASHCROFT catalogs and technical brochures
-
A4A Precision Pressure Gauge
4 Pages
-
1084 Test Gauge
2 Pages
-
1001T Panel Mount Gauge
4 Pages
-
1000 Commercial Gauge
2 Pages
-
Type 1339 Duplex Gauge
2 Pages
-
1038A Duplex Pressure Gauge
2 Pages
-
1220 Pressure Gauge
3 Pages
-
2008 Panel Pressure Gauge
4 Pages
-
1198 Finned Siphon
2 Pages
-
2198 MicroTube™ Siphon
3 Pages
-
1098 and 1100 Siphons
5 Pages
-
CI Bimetal Thermometer
2 Pages
-
EI Bimetal Thermometer
2 Pages
-
T6500 Pressure Gauge
5 Pages
-
T5500 Pressure Gauge
5 Pages
-
1109 Pressure Gauge
2 Pages
-
Acid Leak Detection (ALD)
4 Pages
-
5503
2 Pages
-
1209
3 Pages
-
1290
2 Pages
-
2462
2 Pages
-
Type 1133
2 Pages
-
Type 1127/1128
2 Pages
-
Model C-600A-03
2 Pages
-
Industry sanitary-pharm
4 Pages
-
302-303
4 Pages
-
T5500E
2 Pages
-
IXLDP
2 Pages
-
k1
2 Pages
-
K2
2 Pages
-
K8
2 Pages
-
km15
2 Pages
-
KS Sanitary
2 Pages
-
KX Transducers
2 Pages
-
RXLDP
2 Pages
-
SL17-TTS
1 Pages
-
SL 17 Submersible
2 Pages
-
T2 Transducers
2 Pages
-
600-02
2 Pages
-
600-03
2 Pages
-
600-04
2 Pages
-
600B
2 Pages
-
600H
2 Pages
-
ar10
4 Pages
-
ar20
4 Pages
-
at30 skin type thermocouple.
4 Pages
-
Type ST-2A Digital Indicator
2 Pages
-
Type 1305D Deadweight Tester
2 Pages
-
Model PT-1 Pressure Tester
2 Pages
-
ATE-2 Handheld Calibrator
12 Pages
-
SWGL
7 Pages
-
sw10
9 Pages
-
A N4
4 Pages
-
A series
8 Pages
-
600A
2 Pages
-
DT 600A
2 Pages
-
ash A4
2 Pages
-
A4
2 Pages
-
A2X
2 Pages
-
ASH DIG
3 Pages
-
DG 25
3 Pages
-
1008S
2 Pages
-
1008 A AL
2 Pages
-
1125
1 Pages
-
1009 1010
1 Pages
-
1010
2 Pages
-
test gauges
3 Pages
-
1259
2 Pages
-
Ash SW10
9 Pages
-
Ash SWA
8 Pages
-
Ash DG 25
3 Pages
-
Ash DG
2 Pages
-
Ash Bul
3 Pages
-
Ash EL
2 Pages
-
Ash BM
2 Pages
-
Ash A2x
2 Pages
-
Ash A2 1 3
2 Pages
Archived catalogs
-
Bimetal Thermometers - Series CI
8 Pages
-
Sanitary Gauges - Type 1032
4 Pages
-
Industrial Gauges Type 1017
24 Pages
-
Process Gauges Type 1279
16 Pages
-
Test Gauges Type 1082
12 Pages