video corpo

2198 MicroTube™ Siphon - 3 Pages

Add to MyDirectIndustry favorites
2198 MicroTube™ Siphon

Catalog excerpts

Data Sheet 2198 MicroTube™ Siphon FEATURES For working pressure up to 5,000 psi For process temperature up to 800°F (427°C) Compatible with many process media For use with gauges, switches, transducers and diaphragm seals TYPICAL USES Chemical and petrochemical Oil and gas Pulp and paper Power SPECIFICATIONS Process Connection: ¼ NPT Male, ½ NPT Male G ¼ B Male, G ½ B Male MicroTube™ Siphon Instrument Connection: ¼ NPT Female, ½ NPT Female G ¼ B Female, G ½ B Female Wetted Material: Max Allowable Working Pressure: BENEFITS • Protects instrument from elevated temperatures • tem mount instrument to process S SIPHON HEAT DISSIPATION CHART This graph represents the heat dissipation based on results of a specific laboratory test. These results may vary in the field based on multiple factors such as ambient temperature, type of process media and/ or velocity. This data set is to be used as a reference point only. These test results are based on an ambient temperature of 68°F. Bourdon Tube Siphon Outlet Siphon Outlet Siphon Inlet Input Process Temperature All specifications are subject to change without notice. All sales subject to standard terms and conditions.

 Open the catalog to page 1

Data Sheet C ASHCROFT Trust the shield.® Options (if choosing an option(s) must include an “X”)    —X _ NH - SS tag wired to siphon C3 - Material traceability report to EN 10204 3.1    C3 F3 - Instrument assembly: pressure gauge, diaphragm seal, siphon K9 - Instrument assembly: pressure gauge, capillary siphon, diaphragm seal 5G - Siphon attached to instrument All specifications are subject to change without notice. All sales subject to standard terms and conditions. ©2018 Ashcroft Inc. Ash Bul S-2 (2198) (LR), Rev. A, 02/18

 Open the catalog to page 2

Data Sheet 2198 MicroTube™ Siphon 2198 SIPHON DIMENSIONS Pressure Connection Instrument Connection Siphon Variation Cage Details Overall Length C Hex Height Instrument Connection E 3 of 3 All specifications are subject to change without notice. All sales subject to standard terms and conditions.

 Open the catalog to page 3

All ASHCROFT catalogs and technical brochures

  1. 1084 Test Gauge

    2 Pages

  2. 5503

    2 Pages

  3. 1209

    3 Pages

  4. 1290

    2 Pages

  5. 2462

    2 Pages

  6. Type 1133

    2 Pages

  7. Type 1127/1128

    2 Pages

  8. Model C-600A-03

    2 Pages

  9. 302-303

    4 Pages

  10. T5500E

    2 Pages

  11. IXLDP

    2 Pages

  12. k1

    2 Pages

  13. K2

    2 Pages

  14. K8

    2 Pages

  15. km15

    2 Pages

  16. KS Sanitary

    2 Pages

  17. KX Transducers

    2 Pages

  18. RXLDP

    2 Pages

  19. SL17-TTS

    1 Pages

  20. T2 Transducers

    2 Pages

  21. 600-01

    2 Pages

  22. 600-02

    2 Pages

  23. 600-03

    2 Pages

  24. 600-04

    2 Pages

  25. 600B

    2 Pages

  26. 600H

    2 Pages

  27. ar10

    4 Pages

  28. ar20

    4 Pages

  29. SWGL

    7 Pages

  30. sw10

    9 Pages

  31. A N4

    4 Pages

  32. A series

    8 Pages

  33. 600A

    2 Pages

  34. DT 600A

    2 Pages

  35. ash A4

    2 Pages

  36. A4

    2 Pages

  37. A2X

    2 Pages

  38. ASH DIG

    3 Pages

  39. DG 25

    3 Pages

  40. 1008S

    2 Pages

  41. 1008 A AL

    2 Pages

  42. 1125

    1 Pages

  43. 1009 1010

    1 Pages

  44. 1010

    2 Pages

  45. test gauges

    3 Pages

  46. 1259

    2 Pages

  47. Ash SW10

    9 Pages

  48. Ash SWA

    8 Pages

  49. Ash DG 25

    3 Pages

  50. Ash DG

    2 Pages

  51. Ash Bul

    3 Pages

  52. Ash EL

    2 Pages

  53. Ash BM

    2 Pages

  54. Ash A2x

    2 Pages

  55. Ash A2 1 3

    2 Pages

Archived catalogs