Data Sheet C ASHCROFT Trust the shield.® ■ Full Scale Total Error Band (TEB) includes the effects of linearity, hysteresis, repeatability and temperature from 0 °F to 150 °F (-18 °C to 63 °C) ■ Field calibration capability ■ Test bench / gauge repair facilities ■ Mobile calibration labs ■ Test measurement and validation Accuracy: 2089: ±0.05% of span accuracy 2086: ±0.10% of span accuracy 2084: ±0.25% of span accuracy Terminal Point, Total Error Band (TEB) Including Hysteresis, Linearity, Repeatability and Temperature (0 °F to 150 °F) Case Material: 300 Stainless Steel Case Finish: Tumble polished Storage/Protection: Stainless steel face cover (included) Zippered gauge pouch (included) Black or orange rubber boot (optional) Carrying Case: Weatherproof ABS gauge carrying case (optional) Process Connection: V4 NPT Male Process Connection Location: Lower, left or right Mounting: Stem Ranges: Gauge, compound, absolute and vacuum thru 7,000 psi (see engineering units on page 3 for other units of measurement) Calibration Chart: 10 point traceable calibration chart included. ISO/IEC 17025 certified calibration with chart (optional) Enclosure Rating: Weatherproof, IP65 WETTED COMPONENTS KEY BENEFITS • Highly accurate test instruments • Silicone MEMS sensor technology provides accuracy and long term stability • Rugged and portable design • Twelve engineering units NON-WETTED COMPONENTS Process Connection and Sensor Backlight: Off by default, programmable Manually turns backlight on and off Battery Life: 1,000 hrs. (3 AAA alkaline batteries) All specifications are subject to change without notice. All sales subject to standard terms and conditions. 1 of 3 Ashcroft® and Trust the Shield® are trademarks of Ashcroft Inc. For more information see Ashcroft Brands &Trademarks ©2022 Ashcroft Inc. 2084-2086-2089_ds_RevF_10-06-22
Open the catalog to page 1Data Sheet CASHCROFT - Trust the shield.® Range (coding example, see range table below for all standard ranges) All specifications are subject to change without notice. All sales subject to standard terms and conditions. 2 of 3 Ashcroft® and Trust the Shield® are trademarks of Ashcroft Inc. For more information see Ashcroft Brands &Trademarks ©2022 Ashcroft Inc. 2084-2086-2089_ds_RevF_10-06-22
Open the catalog to page 2Data Sheet C ASHCROFT Trust the shield.® MENU MODE DIMENSIONS in inches Engineering Units: psi, inHg, inH2O, ftSW, Bar, mBar, kPa, mPa, Configuration Mode Access configuration menus to select available (Config): options Auto Off (Off): Allows for changes to auto off of gauge, five Update Rate (Update): 100 ms, 200 ms, 500 ms or 1 sec Dampening (Damp): None, average, 2, 4, 6 or 8 times per 100 ms Field Recalibration: Allows for recalibration of zero, midscale and span (password protected) KEYPAD FUNCTIONS On/Off: Manually turns unit on and off (auto off options in configuration menu) Min./Max....
Open the catalog to page 316 Pages
4 Pages
5 Pages
4 Pages
4 Pages
4 Pages
4 Pages
4 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
3 Pages
4 Pages
2 Pages
3 Pages
5 Pages
2 Pages
2 Pages
5 Pages
5 Pages
2 Pages
4 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
4 Pages
4 Pages
2 Pages
2 Pages
2 Pages
12 Pages
7 Pages
9 Pages
4 Pages
8 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
2 Pages
8 Pages
4 Pages
24 Pages
16 Pages
12 Pages