Group: ASCON TECNOLOGIC Group

Catalog excerpts

BC. 04.01 S2/E Stand-alone remote I/O modulesfor Fieldbus Solutions sigma due > series > Ε Powerful processingcapability Multifunction Modules for Maximum FlexibilityՕ Fully software configurable Built-in Fieldbus Interface for CANopen and ModbusՕ Network Adapters forPROFIBUSDP and Ethernet Easy wiring with built-in terminal blocksՕ DIN rail mounting Extended temperature range -20..+70 հC E ISO 9001 Certified size="-3">
Open the catalog to page 1
Over 30 years of experience in processcontrol and machine automation, guarantees to Ascons sigma due due Multifunction Modules for MaximumFlexibility Through software configuration, sigma > Ү I/O series an effective functional approach to industrial applications.ASCON has grown from manufacturing a leading portfolio of process controllers to a new, complete family of Stand alone modules for EffectiveDistributed Automation The modules are directly connected with fieldbus, each being a stand alone module including built-in terminal blocks for sensors and actuators wiring. A fast bus...
Open the catalog to page 2
due Powerful processingcapability on board The embedded microprocessor takes care of the most common operations, such as linearisation, data scaling, engineering units conversion, alarm handling. This relieves the PC or PLC CPU from a considerable load of computing power, thus improving performance and bus efficiency. Fieldbus Interfaces Built-in for: - CAN with CANopen protocol - RS485 with Modbus protocol. Open to other Fieldbuses through the sigma > Network Adapters to allow integration with: - PROFIBUS DP - Ethernet. Mounting Easy installation and Quick Wiring Modules can be distributed...
Open the catalog to page 3
sigma due I/O moduleAI-08TC8 Analogue Inputs, TC, mV sigma due I/O moduleAI-08HL8 Analogue Inputs mA, V Functions: signal conditioning,linearisation, scaling, engineering units, limits,Յ 16 bit ADC Օ 50 ms conversion time 0,1% accuracy Օ TC (J, K, L, N, R, S, T) ŕ -50..+50 mV -300..+300mV Օ -1..+1V 800 Vp channel-to-fieldbus isolation sigma due I/O moduleAI-02UI2 Isolated Universal Analogue Inputs: TC, RTD, mA, mV, V, Potentiometer Օ Functions: linearisation, limits,ŕ 16 bit ADC 5 ms conversion time Օ 0,1% accuracy 0/4 .. 20 mA Օ 0..10V (-10..0..+10V to come) 800 Vp channel-to-fieldbus...
Open the catalog to page 4
sigma due I/O moduleDM-08TS sigma due I/O moduleDM-16TS sigma due I/O moduleAI-08HL8 Analogue Outputs, mA, V sigma due I/O moduleDM-32TS8 Digital Inputs/Outputs8 Digital Inputs + 8 Digital Outputs 16 Digital Inputs + 16 Digital Outputs sigma due I/O moduleAI-04RT4 Analogue Inputs, RTD, TC, mV Functions: scaling, signal conditioningՕ 16 bit DAC 20 ms conversion time Օ 0,1% accuracy 0/4..20mA Օ 0..10V (-10..0..+10V to come) 800 Vp channel-to-fieldbus isolation Օ Functions: 2 inputs counter, pulse frequency, pulse width (DM-08TS) 2 outputs PWM pulse, single pulse (DM-08TS) 24Vdc optoisolated...
Open the catalog to page 5
sigma due I/O moduleDO-04RL4 Relay Digital Outputs sigma due I/O moduleDO-16TS sigma due I/O moduleDO-16TP Functions: Output status with polarity, pulse outputՕ SPST 250Vac 2A SSR 250Vac 1A Օ 800 Vp channel-to-fieldbus isolation sigma due I/O moduleDI-16LV sigma due I/O moduleDO-32TS16 Digital Outputs 16 2A Digital Outputs 32 Digital Outputs sigma due I/O moduleDI-32LV16 Digital Inputs32 Digital Inputs Functions: Output status with polarity, pulse outputՕ 24Vdc, 0,5A and 2A (DO-16TP) 800 Vp channel-to-fieldbus isolation Օ Functions: Input status with polarity, edge detect, latch 24Vdc...
Open the catalog to page 6
sigma due I/O moduleNA-00PBNetwork Adapter to PROFIBUS DP sigma due I/O moduleNA-00ETNetwork Adapter to Ethernet > Ε 12 MHz DP slave node Connects up to 32 sigmadue I/OModules to PROFIBUSՕ Fully configurable via PROFIBUS Connects up to 32 sigmadue I/O Modules to EthernetՕ Fully configurable General purpose moduleswith integrated special functionsՕ Direct connectivity to sensors and actuators 2, 4, 8, 16, 32 - channelmodules, individually configurableՕ Hot-swap capability Each module is autonomouswith isolated standard interface to CANopen or RS485 ModbusՕ Programmable Power-upstatus 24 Vdc...
Open the catalog to page 7All ASCON TECNOLOGIC catalogs and technical brochures
-
REFRIGERATION CATALOGUE 2020
85 Pages
-
NP4
2 Pages
-
ZIS EIIRLIBGPMAT2018
1 Pages
-
KR1E
4 Pages
-
VA7810 Series Self-Calibrating
10 Pages
-
ClimaPAC
8 Pages
-
at on cloud
8 Pages
-
Sensitive Touch - Data sheet
4 Pages
-
Z31/Y39 - Data sheet
4 Pages
-
ASCOMB - Technical bulletin
12 Pages
-
CATALOGO PRODOTTI 2014/2015
113 Pages
-
Refrigeration catalogue 2016
168 Pages
-
TCPDE M
2 Pages
-
Sensitive Touch
4 Pages
-
opmt
2 Pages
-
m81
6 Pages
-
MP02
2 Pages
-
Loop_components_catalogue_2015
49 Pages
-
Deltadue series
8 Pages
-
Gammadue series
8 Pages
-
IO-CB series
4 Pages
-
Climatic test chambers.
2 Pages
-
Paperless recorder
4 Pages
-
Industrial operator panel
2 Pages
Archived catalogs
-
TRH-MINI
3 Pages
-
TRH52
4 Pages
-
TRH21
4 Pages
-
Pneumatic Actuators
7 Pages