Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm
6Pages

{{requestButtons}}

Catalog excerpts

Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm - 1

BT. 02.19 M5/E Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm gammadue® series M5 line Advanced features, customizable and process adaptable High speed data aquisition and signal management. Efficent information transfer to the supervisor. Ability to adapt itself to changing process conditions. The most sophisticated 48 x 48 of the gammadue® series is user-friendly due to easy and customizable procedures. The outputs (analogue, time proportioning or valve control) are freely addressable to the different functions like control, alarm or retransmission. The programmable Setpoint and the memory chip help the M5 line achieve mini process controller status. ISO 9001 Certified ASCON spa Via Falzarego, 9/11 - 20021 Baranzate - (Milano) Italy - Tel. +39 02 333 371 - Fax +39 02 350 4243 http://www.ascon.it e-mail info@ascon.it E UL ®

Open the catalog to page 1
Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm - 2

2 Your needs Our solutions gammadue® the right solution to your needs High speed data acquisition and signal management Use of different actuators Process with time variable characteristic Alarm signalling and diagnostic Interfacing with other devices Temperature profile Safe and reproducible configuration and parameter settings Quick learning Ergonomic compatibility with other devices Environmental protection Easy to use Noise immunity Universal input signals, linear as well as non-linear Reliability and safety Technical support Sampling time: 100ms measure update time: 50 ms Analogue...

Open the catalog to page 2
Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm - 3

3 Technical data Features at env. 25°C Description Input type RTD Pt100Ù at 0°C RTD 2xPt100Ùat 0°C for ÄT T/C type J Fe-Cu 45% Ni T/C type T Cu - CuNi T/C type K Cromel Alumel T/C type S Pt10%Rh-Pt 0/4…20 mA, 0…50 mV 0/1…5 V, 0…10 V Configurable engineering units mA, mV, V, bar, psi, Rh, ph 0…1600 °C 32…2912 °F 0…1200 °C 32…2192 °F -200…400 °C -328…752 °F 0…600 °C 32…1112 °F -50.0…50.0 °C -58.0…122.0 °F -200…600 °C -328…1112 °F -99.9…300.0 °C -99.9…572.0 °F Scale range Table 1 : PV input mV Custom scale On request The choices are: input type, operating mode, type of control, safety...

Open the catalog to page 3
Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm - 4

4 Technical data Control output Alarms Galvanic isolation 500Vac/1min Resolution: 12 bit (0.025%) Accuracy: 0.1% Short circuit protected Max. slope 0.01…99.99%/s up and down Safety value -100…100%. User enabled/disabled Time proportioning 2 Relays 2 Triacs SSR drive Analogue (optional) Current Voltage Motorised valve (3 states) Raise - Stop - Lower SPST NO, 2A/250Vac resistive load - hysteresis 0.1…5.0% symmetrical Action Active high Active low Special functions Ramp up and down, with slope in digit/s, digit/minute or digit/hour between 0.0…10.0% of the range High and low limits 1 program,...

Open the catalog to page 4
Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm - 5

Tuning Integrity in data copy Fast view - fast parameter access Setpoint programmer Two methods of tuning are available: - Auto-Tuning “one shot” - Adaptive-Tuning continuous and self-teaching The Auto-Tuning method works best on the step response basis. When activated it modifies the output value and, in a short time, calculates the PID parameters. The new algorithm is operational immediately. The main advantages of this method are fast calculation and quick implementation. The ASCON self teaching Adaptive-Tuning waits for process change to recalculate the new PID parameters. The new PID...

Open the catalog to page 5
Process controller Setpoint programmer 1/16 DIN - 48 x 48 mm - 6

Model: Power supply Outputs Serial comm.s/Options Setpoint Instr. handbook Colour Ordering codes M5 A B C D – E F G 0 A35 B1245 C D 0 0 0 1 0 2 0 3 0 4 0 5 5 0 5 1 5 2 5 3 5 4 E01 F0123 G01 Power supply 100...240Vac (-15...+10%) 24Vac (-25...+12%) or 24Vdc (-15...+25%) Outputs OP1 (OP2) Relay-Relay Relay-Triac Triac-Relay Triac-Triac Serial comm.s Options None [2] Auxiliary Feedback potentiometer [2] Not fitted input Remote Setpoint [1] Current transformer Auxiliary SSR drive/Analogue output SSR drive/Analogue + Remote Setpoint [1] [2] None [2] RS 485 Auxiliary Feedback potentiometer [2]...

Open the catalog to page 6

All ASCON TECNOLOGIC catalogs and technical brochures

  1. NP4

    2 Pages

  2. TRH-MINI

    3 Pages

  3. TRH52

    4 Pages

  4. TRH21

    4 Pages

  5. KR1E

    4 Pages

  6. ClimaPAC

    8 Pages

  7. at on cloud

    8 Pages

  8. TCPDE M

    2 Pages

  9. opmt

    2 Pages

  10. m81

    6 Pages

  11. MP02

    2 Pages

  12. IO-CB series

    4 Pages

Archived catalogs