General Description
This document provides an installation manual for a modular system designed for DIN rail mounting, specifically DIN 35 x 7.5 (EN 50022). It includes various components such as male and female connectors, RJ45 plugs, and rotary switches for setting Node ID and Baud rate. The system is ISO9001 certified.

Accessories
The system includes several accessories such as additional terminal blocks, connectors with screw or spring terminals, CANopen cables, and RJ45 plugs with termination circuitry. Power supplies of 45W and 120W are also available.

Installation
The installation process involves mounting the module on a DIN rail, ensuring proper ventilation, and connecting the modules using standard cables. The document provides detailed steps for mounting and removing modules, as well as hot swapping procedures.

Operating Conditions
The system operates within a temperature range of -10 to +65°C and humidity of 5 to 95% RH, non-condensing. Special conditions such as corrosive or explosive atmospheres require additional precautions like forced ventilation or filters.

Electrical Connections
Electrical connections involve using 11-pole connectors and ensuring proper power supply connections. The document emphasizes the importance of matching power supply with module requirements and avoiding excessive voltage drops.

CANopen Connection
The CANopen network is connected using RJ45 connectors, with specific pin assignments for signals like CANH, CANL, and GNDCAN. The document provides guidelines for network termination and maximum fieldbus network lengths based on baud rates.

Electrical Safety and EMC
The system complies with EN 61010-1 for electrical safety and EN61000-6-4 and EN61000-6-2 for electromagnetic compatibility. Installers are responsible for ensuring compliance with safety and EMC regulations.

Precautions and Notes
Precautions include routing supply wiring away from power cables, avoiding electromagnetic interference, and using shielded cables for sensor inputs. The document also notes that the controller has no user-serviceable parts and requires specialized repair services.
See more

Catalog excerpts

IO-CB series-1

CANopen Analogue I/O Modules Installation Manual ASCON spa 20021 Baranzate (Italy) Fax +39 02 350 4243 www.ascon.it [email protected] Contents - General description - Accessories - Installation - Electrical connections - Electric safety 2 Isolated Analogue Inputs 4 Configurable Analogue Inputs 8 Voltage Analogue Inputs 8 Configurable Analogue Inputs 8 Thermocouple Analogue Inputs 8 ±10V Output Channels 8 High Level Analogue Inputs General description Operating conditions Environmental condition Operating conditions Additional terminal block Special conditions Forbidden conditions - Mount the module vertically - In order to help the ventilation flow of air, respect the distances between modules and walls or other modules. - Model identification label (on the back side of the module) - DIN RAIL 35 x 7.5 (EN50022) - 2 male 11 pole plugs, pitch 5.0mm - 2 + 2 female, 11 pole, fast snap-ON connectors, pitch 5.0mm, with screw or spring terminals to connect the power supply or the I/O (accessory) 5 - Two RJ45 plugs to connect the field bus 6 - CANopen cable with two RJ45 connectors (accessory) 7 - RJ45 plugs with internal termination circuitry (accessory) 8 - 2 rotary switches having 16 positions to set Node ID and Baud rate 9 - Removable and writable label to identify the connected I/O (TAG number) 10 - 4 status LEDs: identify the diagnostic and the module status 11 - Additional terminal block 2 x 11 poles (accessory) P Conducting atmosphere C Corrosive atmosphere Mounting/removing the modules on/from the DIN rail 1 Close the spring slide, then clip the upper part of the module on the rail 2 Rotate the module downwards till to the click 3 Switch OFF the Power Supply Lower the spring slide by inserting a flatblade screwdriver as indicated 4 Turn and lift the module upwards. Mounting the module 2 Accessories Power supply 45W - 2A/24 Vdc Field bus cables with RJ45 connectors With screw terminals: AP-S2/SPINA-V11 With spring terminals: AP-S2/SPINA-M11 Additional terminal block 2 connectors with termination circuitry Node ID and Baud rate of the new module must already be correctly set. The procedure to minimize the MODBUS disconnection time follows: 1 Remove all the cabled connectors from their plugs (item 4 in “General description” paragraph), do not extract the MODBUS RJ45 connectors yet 2 Remove the module from the DIN rail 3 Mount the new and already configured module on the DIN rail 4 Extract the left side RJ45 connector from the module and insert it in the new module 5 Extract the right side RJ45 connector from the module and insert it in the new module 6 Insert all the cabled connectors in the new module.

 Open the catalog to page 1
IO-CB series-2

Electrical connections Terminals connections and plugs Technical data: - Two/Four 11 poles plugs, pitch 5.0 mm - Made with self extinguishing material as required by UL94 V0 standard - Overvoltage cathegory/pollution degree II/2 - Max. load current/section 8A/2.5mm2 at 65°C - Test pulse voltage: 4 kVp. Description Flexible cable section: Additional terminal block (connection example) Tightening torque Maximum length of the fieldbus network: Meters 2500 1000 500 250 100 50 25 Baud rate 20 kbps 50 kbps 125 kbps 250 kbps 500 kbps 800 kbps 1000 kbps The signals present in the two RJ45 connectors...

 Open the catalog to page 2
IO-CB series-3

Inputs: Pt100, PtIOOO resistance thermometers (2, 3 wires) When 3 wires system is used, always use cables of the same section (1 mm2 When 2 wires system is used and the distance between the module and the section cable produces a 1 °C (1.8°F) measure error. Inputs: mV and J, K, L, N, R, S, T thermocouple type Respect the polarity shown; To extend the connection, use always compensation cable of the correct type When present the shield must be connect- ed to a proper earth (at only one end). Inputs: potentiometer Thermocouple input To extend the connection, use always compensation cable of the...

 Open the catalog to page 3
IO-CB series-4

Output: analogue device (V) Output: analogue device (V) Analogue device Respect the polarity shown Respect the polarity shown Analogue device Respect the polarity shown Electric safety and electromagnetic compatibility Class II instrument, rear panel mounting. This instrument has been designed in compliance with: Regulations on electrical equipment: according to regulations on the essential protection requirements in electrical equipment EN 61010-1 Regulations on Electromagnetic Compatibility according to: - Regulations on RF emissions: EN61000-6-4 industrial environments; - Regulation on RF...

 Open the catalog to page 4

All ASCON TECNOLOGIC catalogs and technical brochures

  1. NP4

    2  Pages

  2. KR1E

    4  Pages

  3. at on cloud

    8  Pages

  4. TCPDE M

    2  Pages

  5. opmt

    2  Pages

  6. MP02

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.