Group: ASCON TECNOLOGIC Group
Catalog excerpts
3 Digital inputs: Alarms: 2 or 4 with ISA-A acknowledge. Independently configurablefor alarms, display, and calibration handlingՅ Second input: Retransmission output: DC voltage and DC current. Suitable for temperature indication and signal conditioning (min., max., average, ratio, etc.) when combined with the Main input.Օ optional, DC current Communications: optional, Modbus RS485.Օ Parameters protection: 3 password levels. BT. 02.36 J5/E > Accuracy: 0.1%Օ Measurement resolution: 16 bit. Overall response time: 20 ms.Օ > CUSLISTED configurable 1... 100 digit.Ε Main input: > 350 Ω strain gauge, linear DC voltage and DC current. Square root extraction 16 segments linearizer for customӔ input. Accurate measurement of meltpressure and other process variables are provided by J5. The J5 is fully configurable from the keyboard or by means of a software configuration tool. The J5 display utilizes a large, bright 5 digit LED that can be configured to operate ingreen or red. The display can be configured to change color when in alarm condition.Օ >
Open the catalog to page 1Keyboard lock/unlock : to prevent unauthorized operator actions The 350 Ħ Outputs lock/unlock strain gauge bridge of the Melt pres-sure or load cell trasducer can be energized by an internal stabilized 5 or 10Vdc. The reliability of the strain gauge is continuously monitored.A simple front panel calibration routine is pro-vided to automatically remove zero and span offsets. The automatic calibration routine can also be activated by using one of the three standard digital inputs, as well as being activat- ed over serial communications. Tare function for load cells application is also...
Open the catalog to page 2Second input IN2AnalogueOutput DC Input IN1 V > EXC SIGCAL Main input IN1 >
Open the catalog to page 3All ASCON TECNOLOGIC catalogs and technical brochures
-
NP4
2 Pages
-
TRH-MINI
3 Pages
-
TRH52
4 Pages
-
TRH21
4 Pages
-
ZIS EIIRLIBGPMAT2018
1 Pages
-
KR1E
4 Pages
-
Pneumatic Actuators
7 Pages
-
VA7810 Series Self-Calibrating
10 Pages
-
ClimaPAC
8 Pages
-
at on cloud
8 Pages
-
Sensitive Touch - Data sheet
4 Pages
-
Z31/Y39 - Data sheet
4 Pages
-
ASCOMB - Technical bulletin
12 Pages
-
CATALOGO PRODOTTI 2014/2015
113 Pages
-
Refrigeration catalogue 2016
168 Pages
-
TCPDE M
2 Pages
-
Sensitive Touch
4 Pages
-
opmt
2 Pages
-
m81
6 Pages
-
MP02
2 Pages
-
Loop_components_catalogue_2015
49 Pages
-
Deltadue series
8 Pages
-
Gammadue series
8 Pages
-
IO-CB series
4 Pages
-
Climatic test chambers.
2 Pages
-
Paperless recorder
4 Pages
-
Industrial operator panel
2 Pages