Stability: Օ Electrical connections: Terminal strip or 5 pole M12 connectors Long-term drift < 0.5 RH%/year. ՓHumi-Chip environmentallimits: -30...+90C Housing: Օ Protection filter: IP66, for both wall, duct and remote sensor models. Wire mesh/sintered stainless steel or teflon, protects against dust and other atmospheric contaminants. B.T. 11.03.H1/E The > ԕAccuracy: RH% 1.8 between 10 and 90% Temperature 0.5C max. Humi-chip Д module thatincorporates the sensor can be easily interchanged without the needfor re-calibration.For further operator ease of use,relative humidity values can bedisplayed on the optional integrated LCD display, or sentvia analogue outputs to other display devices. H1 transmitter operates byusing the value made by a highly accurate capacitive sensor that is integrated in a silicon microchip.This new technology allows foraccurate process measurements, is extremely reliable, and offers excellent long-term stability. The sensor is very durable and moisture resistant.The ԓ > Humidity and Temperatureoutputs: 4Յ20mA 2 wire or 010V Both analogue outputs are isolated. Temperature output is also available in RTD (Pt100 3 wire) version. >
Open the catalog to page 1Range0Ѕ100% RHOutput420mA 2 wire; 500 Working limits of œ Humi-chip module ԢĦ max. or > Isolated vs. Humidity output > The measured reading tolerance is guaranteedthrough the Normal Ӕ working conditions.A long-time period, at Accuracy (figure 3) Output 4Ӆ 20mA <0.5C between -20Ѕ 80C (-4... 176аF) > Limit conditions maygenerate a permanent drift up to +2 RH %. Output 0ԅ 10V <0.5C between 0Ѕ 50C (32... 122аF)RTD output - asalternative(PT100 IEC 751) to mA or V outputTolerance: Class B (1/2 DIN) - 3 wire connection Humidity Tolerance Digital display dimensions10.5mmDisplay range0.0 100.0% RH > Figure...
Open the catalog to page 2Model:Mounting - DimensionsProbe material FilterLCD Display (option)Electrical connectionsTemperature output (option)Humidity output > MountingDimensionsWall13 x L52Ductؘ20 x L25020 x L500Remoteؘ20 x L100, cable 2m20 x L100, cable 4 m AB 1 > st output - Humidity4... 20 mA (2 wire) / 0... 100% RH0... 10 V / 0... 100% RH E P0 12 C2 C5 > nd R2R4 2 output - Temperature (option)Not fitted4...20 mA (2 wire)when 1 F > st output = 4...20 mA0...10 Vwhen1 1 Probe materialPVDF plastic C0 > st output = 0...10 VPT100 - Compliance with IEC751 2P 2 bis, Rue Paul Henri SpaakST. THIBAULT DES VIGNES F-77462 LAGNY...
Open the catalog to page 485 Pages
2 Pages
4 Pages
8 Pages
4 Pages
4 Pages
12 Pages
2 Pages
4 Pages
2 Pages
2 Pages
49 Pages
8 Pages
8 Pages
4 Pages
2 Pages
4 Pages
2 Pages
6 Pages
168 Pages
113 Pages
8 Pages
10 Pages
1 Page
7 Pages
4 Pages
4 Pages
3 Pages