Group: ASCON TECNOLOGIC Group
Catalog excerpts
deltadue® series Control and acquisition modules with fieldbus for DIN rail mounting Not just I/O modules Process and Temperature controllers Analogue and digital I/O modules Transmitters with alarm thresholds PROFIBUS DP / DeviceNet / CANOpen / Modbus TCP/ Modbus RTU fieldbus Interfaces • A complete range of compact and flexible modules • PC configurable • Wide choice of Operator Panels • Built-in RS 485 Modbus • Fits the most common architectures
Open the catalog to page 1ASCON’S CONTROL AND ACQUISITION deltadue® series ASCON’s process control experience and the increasing need for integration of the control systems have brought to the development of the new deltadue® series, consisting in control and acquisition modules. Modular Multiloop The deltadue® modules can either be rear panel or on-machine mounted. This way, control panels can be more compact and distribution on the plant or on the machine can be optimized. The modules are independent. Each module can work as a single unit or within a set of modules as a part of a stand-alone control system, or...
Open the catalog to page 2ON MODULES FOR DIN RAIL MOUNTING ...open to the external world... D7, D8, D9 Acquisition and Transmitter modules • Universal single loop controllers • Independent dual loop controllers All modules have RS485 and Modbus protocol for direct connection to most common Operator Panels and SCADAs. Integration into PROFIBUS DP or DeviceNet or CANOpen or Modbus TCP or Modbus RTU by means of the Gateway modules DX and DY. ...with the “Manager-Gateway”... The optional DX module includes two important functions - management of the connected deltadue® modules for offline configuration, data back up and...
Open the catalog to page 3Icons table: PV input Thermocouple RTD Pt100 Delta temperature (2xRTD) mA and mV “Custom” PID CONTROL MODULES D1 Line - Temperature controller Main universal Input 12 with automatic selection Current transformer One shot Auto tuning One shot Natural frequency Auxiliary inputs Current transformer Fuzzy tuning Digital inputs Serial communications Isolated contact NPN open collector for configuration and supervision purposes Special functions Digital input functions Digital outputs SPST relay SSR PNP open collector SSR drive D2 Line - Dual loop control/acquisition module Main universal Inputs...
Open the catalog to page 4ACQUISITION MODULES D7 Line - Analogue acquisition, alarm thresholds and transmitter module Main universal Input Digital input Serial communications Modbus Slave supervision purposes Digital input functions D9 Line - 2-channel analogue acquisition module Main universal Inputs Digital input Digital input functions Digital outputs Digital outputs can also be used as digital inputs Available functions Serial communications Modbus Slave supervision purposes D8 Line -Digital I/O acquisition module with 6 Inputs and 2 Outputs Digital inputs Available functions Available functions Serial...
Open the catalog to page 5Modular multiloop PID controller with local Operator Panel. Distributed control and acquisition system with DX module (manager and bus interface) for hot swapping and connection to local Operator Panel and remote SCADA. Modular multiloop PID controller with local Operator Panel interfaced with remote SCADA. Distributed I/O modules for acquisition, data logging and centralised supervision of analogue and digital signals with the possibility of alarms and local commands. Industries and Applications Plastic and Rubber: Injection, Extrusion, Hot-Runners Packaging: Thermowelding, Thermoforming...
Open the catalog to page 6systems with external jiooa iflttn gftnq ocoo I i»fto61 piii\ftm\ c." tree: SLCCZ IECC; modules with DX fieldbus interface module. Metal Works: blast Furnaces, thermal treatment Furnaces Glass: blast Furnaces; Furnacesforthe treatment of flat, hollow, curved glass Fine chemistry, Pharmaceutics, Cosmetics, Paints and Enamels Power: Boilers, Burners Refrigeration: climatic Chambers, Chillers Shipyards: hull Automation Water Treatment: waste Waters, Primary Waters, Semi-Conductors.
Open the catalog to page 7ASCON spa The DX module has 3 serial ports and includes two important functions: - Manager - Gateway. The “Manager” memorises the configuration and parameters of each module and monitors that the latter functions correctly. Any time a module is substituted, this is recognised by the DX-Manager, which automatically reconfigures and parametrises the substituted module. The Gateway includes: one fieldbus slave port for the conversion Modbus/PROFIBUS DP, Modbus/DeviceNet and Modbus RTU/Modbus RTU; two RS485 Modbus Master ports for the connection to the deltadue® modules and to other Ascon’s, or...
Open the catalog to page 8All ASCON TECNOLOGIC catalogs and technical brochures
-
NP4
2 Pages
-
TRH-MINI
3 Pages
-
TRH52
4 Pages
-
TRH21
4 Pages
-
ZIS EIIRLIBGPMAT2018
1 Pages
-
KR1E
4 Pages
-
Pneumatic Actuators
7 Pages
-
VA7810 Series Self-Calibrating
10 Pages
-
ClimaPAC
8 Pages
-
at on cloud
8 Pages
-
Sensitive Touch - Data sheet
4 Pages
-
Z31/Y39 - Data sheet
4 Pages
-
ASCOMB - Technical bulletin
12 Pages
-
CATALOGO PRODOTTI 2014/2015
113 Pages
-
Refrigeration catalogue 2016
168 Pages
-
TCPDE M
2 Pages
-
Sensitive Touch
4 Pages
-
opmt
2 Pages
-
m81
6 Pages
-
MP02
2 Pages
-
Loop_components_catalogue_2015
49 Pages
-
Gammadue series
8 Pages
-
IO-CB series
4 Pages
-
Climatic test chambers.
2 Pages
-
Paperless recorder
4 Pages
-
Industrial operator panel
2 Pages