BC. 02.03 D2/E delta due > seriesControl and acquisition modules with fieldbus for DIN rail mounting > Not just I/O modulesProcess and TemperaturecontrollersAnalogue and digital I/O modules Transmitters with alarmthresholdsPROFIBUSDP / DeviceNet /CANOpen / Modbus fieldbus Interfaces Ε A complete range of compact and flexible modules PC configurable Օ Wide choice of Operator Panels Built-in RS 485 Modbus Օ Fits the most common architectures E ISO 9001 Certified size="-4">
Open the catalog to page 1ASCONs process controlexperience and the increasing need for integration of the control systems have brought to the development of the new delta > Ү series, consisting in control and acquisition modules.Thedelta due > modulescan either be rear panel or on-machine mounted. This way, control panels can be more compact and distribution on the plant or on the machine can be optimized. The modules are independent. Each module can work as a single unit or within a set of modules as a part of a stand-alone control system, or integrated in PLC or PC systems. Integration into PROFIBUS DP or...
Open the catalog to page 2All modules have RS485 and Modbus protocol for direct connection to most common Operator Panels and SCADAs. Integration into PROFIBUS DP or DeviceNet or CANopen or Modbus by means of the Manager-Gateway DX module. > The optional DX moduleincludes two important functions - management of theconnecteddelta due > ծ modules for offlineconfiguration, data back up and hot swapping- serial interface and adaptorfor integration on fieldbus. > due Thedelta due > ծ series includesself-configuring HMIs, from simple compact alphanumeric Operator Panels to Touch Screen Graphic panels. Connected delta >...
Open the catalog to page 3Digital inputMain universal InputOutputs (option) Digital input functions > Serial communications RS485Modbus Slave > for configuration andsupervision purposes Main universal Inputs > 1212 PV1OP1OP2 > 1212 PV2 Digital inputOP3OP4 Digital outputs Digital outputs Every output (OP1...OP4)can be freely combined with the Pv1 or PV2 inputs IL1 Serial communications can also be used as digital inputs RS485Modbus Slave > for configuration andsupervision purposes Digital input functions Available functionsNot > Digital inputsOutput DI1 DO1DO2 DI2 DI3 DI4 Serial communications DI5 RS485Modbus Slave...
Open the catalog to page 5PLC PLCPROFIBUS / DeviceNet / CanOpen Modbus Modbus DX > Industrial Air Conditioning andRefrigeration: climatic Chambers, Chillers Chemistry and Pharmaceutics: Shipyards: hull Automation Fine chemistry, Pharmaceutics,Cosmetics, Paints and Enamels Power: Boilers, Burners Water Treatment: waste Waters, Primary Waters, Semi-Conductors. Metal Works: Glass: blast Furnaces; Furnaces for thetreatment of flat, hollow, curved glass blast Furnaces, thermal treatment Furnaces >
Open the catalog to page 7All ASCON TECNOLOGIC catalogs and technical brochures
-
NP4
2 Pages
-
TRH-MINI
3 Pages
-
TRH52
4 Pages
-
TRH21
4 Pages
-
ZIS EIIRLIBGPMAT2018
1 Pages
-
KR1E
4 Pages
-
Pneumatic Actuators
7 Pages
-
VA7810 Series Self-Calibrating
10 Pages
-
ClimaPAC
8 Pages
-
at on cloud
8 Pages
-
Sensitive Touch - Data sheet
4 Pages
-
Z31/Y39 - Data sheet
4 Pages
-
ASCOMB - Technical bulletin
12 Pages
-
CATALOGO PRODOTTI 2014/2015
113 Pages
-
Refrigeration catalogue 2016
168 Pages
-
TCPDE M
2 Pages
-
Sensitive Touch
4 Pages
-
opmt
2 Pages
-
m81
6 Pages
-
MP02
2 Pages
-
Loop_components_catalogue_2015
49 Pages
-
Deltadue series
8 Pages
-
Gammadue series
8 Pages
-
IO-CB series
4 Pages
-
Climatic test chambers.
2 Pages
-
Paperless recorder
4 Pages
-
Industrial operator panel
2 Pages