This document describes the Modulair 160 series, an automatic soft-start, air-operated monobloc unit designed for pneumatic systems. It provides two main functions: venting the pneumatic system and gradual pressurization after an outage.

Specifications
  • Fluid: Compressed air or neutral gas, filtered, lubricated or unlubricated
  • Ports: G 3/4 to G 1 1/2
  • Operating Pressure: 2 to 16 bar
  • Max. Flow (Qv at 6.3 bar): G 3/4: 10500 l/min (ANR); G 1 - G 1 1/4 - G 1 1/2: 12000 l/min (ANR)
  • Operating Temperature: 0°C to +50°C (+60°C at 12.5 bar)
  • Pilot Ports: G 1/8
  • Construction: Body made of aluminium, internal parts of light alloy and brass, seals of nitrile (NBR)

Choice of Equipment
The document lists various port sizes and corresponding codes for the 3/2 NC shut-off valve and automatic soft-start unit, air operated without silencer.

Options
  • Key locking device attached to adjustment screw, supplied installed; code: 662598

Accessories
  • G1 silencer, code: 34600411
  • Key locking device supplied separately for regulator, code: 34303050
  • Blanking kit for adjustment screw, code: 34307021
  • Blanking plate for adjustment screw, code: 34307022
  • By-pass module

Dimensions and Weights
The document provides dimensions and weights for G 3/4 - G 1 versions, with a weight of 1.465 kg.

Recommended Configurations
Includes locking options for the adjustment screw, such as a unit with a key locking device or a blanking plate.
See more

Catalog excerpts

Series 343 type Modulair-1

Functional diagram automatic version AIR OPERATED SHUT-OFF VALVE AND AUTOMATIC SOFT-START UNIT numanis Modulair 160 - G 3/4 to G 1 1/2 : Compressed air or neutral gas, filtered, lubricated or unlubricated : G 3/4 to G 1 1/2 : 2 to 16 bar : 10500 l/min. (ANR) : 12000 l/min. (ANR) : 0°C, +50°C (+ 60°C at 12,5 bar) : G 1/8 PRESENTATION • This automatic soft-start, air operated monobloc unit provides two main functions: - pneumatic system venting - gradual pressurisation after an outage leading to venting of the system SPECIFICATION FLUID PORTS OPERATING PRESSURE MAX. FLOW (Qv at 6,3 bar) G 3/4 G 1- G 1 1/4 - G 1 1/2 OPERATING TEMPERATURE PILOT PORTS CONSTRUCTION Body : aluminium Internal parts : light allow and brass G 1 1/4 - G 1 1/2 versions - see accessories © 2 x G1/4 ports for mounting of a dia. 50 mm 0-16 bar pressure gauge, code: 34200997 (provide for 1/4 to 1/8 adapter), or an electronic pressure switch LOCKING OPTIONS FOR ADJUSTMENT SCREW Unit with key locking device for Unit with blanking plate for adjustment screw adjustment screw All leaflets are available on: www.asco.com Air Preparation - 8

 Open the catalog to page 1

All ASCO catalogs and technical brochures

  1. FRL Accessories

    14  Pages

  2. 908 series

    2  Pages

  3. Accessories

    2  Pages

  4. Oil and gaz

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.