MAGNETIC POSITION DETECTORS for "T" grooves magneto-resistive (MR) Detectors designed for use in explosive atmosphere zones 0-20, 1-21, 2-22, according to ATEX directive 2014/34/EU. Static non-contact proximity switch on air cylinders equipped with built-in permanent magnets. FUNCTIONAL DESCRIPTION When the permanent magnet which is mounted on the piston approaches the detector the magnetic field it generates causes the semiconductors’ resistors to change. This current variation increases the resistance and a switching signal is generated. DETECTOR CHARACTERISTICS ATEX APPROVAL 00569GB-2016/R01 Availability, design and specifications are subject to change without notice. All rights reserved. MAX. SWITCHING POWER SWITCHING VOLTAGE MAX. SWITCHING CURRENT WIRING REVERSE POLARITY PROTECTION OVERLOAD PROTECTION SHORT-CIRCUIT PROTECTION VOLTAGE DROP (EN 60.947-5-2) CURRENT CONSUMPTION NOMINAL VOLTAGE INTERNAL CAPACITANCE INTERNAL INDUCTANCE HYSTERESIS SWITCHING FREQUENCY SENSITIVITY RESPONSE TIME REPEATABILITY WORKING TEMPERATURE HOUSING CABLE DEGREE OF PROTECTION (IEC 60529) PROTECTION CLASS SIGNAL INDICATION ELECTROMAGNETIC COMPATIBILITY (EMC) CERTIFICATION i without signal II 1GEx ia IIC T4 Ga II 3G Ex nA IIC T4 Gc X II 1D Ex ia IIIC T135°C Da II 3D Ex tc IIIC T125°C Dc X 3W 10 to 30 VDC 100 mA PNP yes yes no yes no yes < 2,5 volt < 10 mA ≤ 1 mA* , ≥ 2 mA** 8,2 V 140 nF 400 µH 1 mm 1 mm > 6000 Hz 2 mTesla 2 mTesla 30 ms < 0,2 mm < 0,2 mm - 25°C , + 70°C - 20°C , + 60°C PA + GF overmoulding PA + GF overmoulding PVC PVC IP67 IP65 / IP67 class III class III yellow diode (LED) which lights up when the contact is established EN 61000-4-2 ESD (electrostatic discharge): -CD/8kV AD EN 61000-4-3 radiated RF fields: 10 V/m (80 ... 2000MHz) EN 61000-4-4 electrical fast transients/burst: 2kV EN 61000-4-6 conducted RF fields: 10 V (0,15 ... 80 Mhz) EN 55011: class B CE, ATEX 1G/D, ATEX 3G/D CHOICE OF DETECTOR Use with barrier Max. values: U=15 V, I=50 mA, P=120 mW PVC lead, 5 m long 2 wires 0,14 mm2 stripped ends PVC lead, 5 m long 3 wires 0,14 mm2 stripped ends Protective cover supplied with detector Weight (g) Compatible cylinders: 50 STANDARD CATALOGUE NUMBER detector detector supplied with cable holding clip and adjustment position stop (1) Detector designed for direct fitting to "T" cylinder grooves (2) Fastening kit required, see page 5 ACCESSORIES AND OTHER ELECTRICAL CHARACTERISTICS: see following page All leaflets are available on: www.asconumatics.
Open the catalog to page 1MAGNETIC POSITION DETECTORS FOR " T " GROOVES - MAGNETO-RESISTIVE (MR) Cable 5 m long, 2 wires 0,14 mm2 stripped ends zones type approval certificate no. DEKRA BVS 10 ATEX 023 (1) Compatible barriers and interfaces ELECTRICAL PROTECTION • Output protected against short-circuit as long as the output current is restricted to 0.1 A. • Improper wire connection may prevent the detector from operating or even destroy it. • It is recommended to install a protection diode (mounted in parallel) on an inductive load in spite of the internal protection. 2 wires (for barrier protection) ● CONNECTION OF...
Open the catalog to page 2All ASCO catalogs and technical brochures
-
FRL Accessories
14 Pages
-
Daniel Orifice Fittings Brochure
10 Pages
-
WIRELESS PRESSURE GAUGES
2 Pages
-
PNEUMATIC PROPORTIONAL VALVES
54 Pages
-
PULSE VALVES 2/2 series 353
2 Pages
-
APPLICATIONS PROCESS INDUSTRY
10 Pages
-
908 series
2 Pages
-
Series 342 Type Modulair
2 Pages
-
Series 343 type Modulair
1 Pages
-
Delta 901 Series
17 Pages
-
Accessories
2 Pages
-
Fluid Automation Solutions
4 Pages
-
WATER REGULATORS
2 Pages
-
JOINABLE REGULATORS
2 Pages
-
ATEX pneumatic components
1 Pages
-
Proportional Valve
2 Pages
-
ILOTS DE DISTRIBUTION PNEUMATIQUE
252 Pages
-
Pneumatic valve islands
252 Pages
-
Flapper valves
4 Pages
-
Packaging equipment
4 Pages
-
Oil and gaz
12 Pages
-
Food and beverage industry
16 Pages