Frank_Regulators
20Pages

{{requestButtons}}

Catalog excerpts

Frank_Regulators - 1

Frank Series Regulators Pressure Regulators, Back Pressure Regulators, Pressure Relief Valves PVC, PP, PPn, PVDF, E-CTFE

Open the catalog to page 1
Frank_Regulators - 2

Frank Series Pressure Regulating Valves Process fluid is isolated from mechanical parts Adjustable under working pressure Adjustment range of 7psi (0.5 bar) to 135psi (9.5 bar) outlet with an inlet of 145psi (10 bar) Gauge guard incorporated into design (V82/182) Low hysteresis (V782): 1.5psi (0.1 bar) to 6.0psi (0.4 bar) Description Pressure regulators keep downstream pressure steady at a set value. Our most popular model, the V82/182 features an integrated gauge guard with pressure gauge. This makes adjustment simple and provides a cost savings package. For further accuracy and stability,...

Open the catalog to page 2
Frank_Regulators - 3

*PVC only. Union with FNPT or IPS socket P.O. Box 653 • 35 Green Street, Malden, MA 02148 • Tel: (800) 343-3618, (781) 321-5409 Fax: (800) 426-7058 • Website: www.asahi-america.com • Email: asahi@asahi-america.com

Open the catalog to page 3
Frank_Regulators - 4

Flow Characteristics Fax: (800) 426 7058 • Website: www.asahi america.com • Email: asahi@asahi america.com

Open the catalog to page 4
Frank_Regulators - 5

Flow Characteristics Fax: (800) 426 7058 • Website: www.asahi america.com • Email: asahi@asahi america.com

Open the catalog to page 5
Frank_Regulators - 6

Size Inch Chem Grade PVDF, Butt Purad HP PVDF, IR Butt Halar E-CTFE, Butt PVDF, Butt, PTFE Chem Grade High Purity P.O. Box 653 • 35 Green Street, Malden, MA 02148 • Tel: (800) 343-3618, (781) 321-5409 Fax: (800) 426-7058 • Website: www.asahi-america.com • Email: asahi@asahi-america.com

Open the catalog to page 6
Frank_Regulators - 7

Setting the operating pressure Installation and operating instructions The valves must be installed without tension, and if possible with a detachable connection. Any desired installation position is possible, and has no influence on the function. Pay attention to the flow direction. This identified on the valve by an arrow. Install a dirt trap for dirty media and media carrying particles. Before start-up, we recommend tightening the housing screws (see table below). Unscrew the grey protective cap from the upper body Loosen the lock nut Turn the adjustment screw with a screwdriver/spanner...

Open the catalog to page 7
Frank_Regulators - 8

Frank Series Back Pressure Regulator Process fluid is isolated from mechanical parts Adjustable under working pressure Adjustment range of 7psi (0.5 bar) to 135psi (9.5 bar) outlet with an inlet of 145psi (10 bar) Low hysteresis: 1.5psi (0.1 bar) to 8.7psi (0.6 bar) Highly accurate and stable control Description Maintain upstream pressure. Non-wetted spring closes the diaphragm to keep pressure constant upstream. When the set pressure is overcome, the valve will open and continue to flow. Size Range: Diaphragm/ Seals: Typically installed at the end of a pressurized line, if your pump fails...

Open the catalog to page 8
Frank_Regulators - 9

*PVC only. Union with FNPT or IPS socket V86/186 Pressure Relief It is often desirable to use a V86/186 back pressure regulator on the branch of a tee to act as a pressure relief valve. The benefits of this configuration are that you can install a higher pressure rated, smaller diameter, less expensive, more readily available valve that will perform in the same manner as a V85/185 pressure relief valve. V85/185 pressure relief valves are popular for tight installations, or high purity projects where dead volume can affect the quality of the water. V85/185 2” Valve & 2x1 Reducer P.O. Box 653...

Open the catalog to page 9
Frank_Regulators - 10

Flow Characteristics Fax: (800) 426 7058 • Website: www.asahi america.com • Email: asahi@asahi america.com

Open the catalog to page 10
Frank_Regulators - 11

Size Inch Size Inch Chem Grade PVDF, Butt Purad HP PVDF, IR Butt Halar E-CTFE, Butt P.O. Box 653 • 35 Green Street, Malden, MA 02148 • Tel: (800) 343-3618, (781) 321-5409 Fax: (800) 426-7058 • Website: www.asahi-america.com • Email: asahi@asahi-america.com

Open the catalog to page 11
Frank_Regulators - 12

Setting the operating pressure Installation and operating instructions The valves must be installed without tension, and if possible with a detachable connection. Any desired installation position is possible, and has no influence on the function. Pay attention to the flow direction. This identified on the valve by an arrow. Install a dirt trap for dirty media and media carrying particles. Before start-up, we recommend tightening the housing screws (see table below). Unscrew the grey protective cap from the upper body Loosen the lock nut Turn the adjustment screw with a screwdriver/spanner...

Open the catalog to page 12
Frank_Regulators - 13

PVDF Butt Flow rate Product Offering Specifications Size Range: Tube: Float: Seals: 1/2” 20 P.O. Box 653 • 35 Green Street, Malden, MA 02148 • Tel: (800) 343-3618, (781) 321-5409 Fax: (800) 426-7058 • Website: www.asahi-america.com • Email: asahi@asahi-america.com

Open the catalog to page 13
Frank_Regulators - 14

Frank Series Pressure Relief Valve Process fluid is isolated from mechanical parts Adjustable under working pressure Install in any orientation Adjustment range of 7psi (0.5 bar) to 135psi (9.5 bar) outlet with an inlet of 145psi (10 bar) Highly accurate and stable control Description Protect your piping system. Non-wetted spring keeps the valve closed until over pressurized. The integrated third spigot provides zero dead volume and minimal pressure loss. Installed inline, this valve can maintain your systems pressure by reducing peaks. Balance out fluctuations in pressure caused by...

Open the catalog to page 14
Frank_Regulators - 15

*PVC only. Union with FNPT or IPS socket V86/186 Pressure Relief It is often desirable to use a V86/186 back pressure regulator on the branch of a tee to act as a pressure relief valve. The benefits of this configuration are that you can install a higher pressure rated, smaller diameter, less expensive, more readily available valve that will perform in the same manner as a V85/185 pressure relief valve. V85/185 pressure relief valves are popular for tight installations, or high purity projects where dead volume can affect the quality of the water. P.O. Box 653 • 35 Green Street, Malden, MA...

Open the catalog to page 15
Frank_Regulators - 16

Flow Characteristics Fax: (800) 426 7058 • Website: www.asahi america.com • Email: asahi@asahi america.com

Open the catalog to page 16
Frank_Regulators - 17

Size Inch Size Inch Chem Grade PVDF, Butt Purad HP PVDF, IR Butt P.O. Box 653 • 35 Green Street, Malden, MA 02148 • Tel: (800) 343-3618, (781) 321-5409 Fax: (800) 426-7058 • Website: www.asahi-america.com • Email: asahi@asahi-america.com

Open the catalog to page 17

All Asahi/America catalogs and technical brochures

  1. PDCPD

    2 Pages

  2. Pool-Pro

    2 Pages

  3. 92 series

    1 Pages

  4. 64 series

    1 Pages

  5. PA series

    2 Pages

  6. 56D/75D

    1 Pages

  7. 10 series

    2 Pages

  8. 94 series

    2 Pages

  9. 92 series

    2 Pages

  10. 87 series

    1 Pages