Electric Globe Control Valves
2Pages

{{requestButtons}}

Catalog excerpts

Electric Globe Control Valves - 1

Sizes: Materials: Model: Stem Seal: Valve Seal: 1/2" – 4" PVC, PP, PVDF and PTFE Flanged (ANSI) PTFE Bellows FKM,, EPDM, PTFE encapsulated FKM Flow Char.: Linear or equal percentage" Temp. Range: PVC 32– 140º F, PP -5 – 175º F PVDF -5 – 265º F, PTFE -5 – 300º F Electric Globe Control Valve Standard Features (Sizes 1/2" - 4") • Precise flow control • Solid thermoplastic valve body provides excellent corrosion resistance • PTFE bellows stem seal eliminates old style packing glands and minimizes maintenance • Positive bubble-tight shut-off • Plug and seat can be changed to accommodate a variety of valve coefficients (Cv) • Plug (trim) can be characterized (linear or equal percentage) per requirements. (See below) • No metal to media contact • Extremely corrosion resistant actuator constructed of glass-filled polyester (PEG) with stainless steel trim • 120 VAC/1ph supply voltage • On/off or modulation • 4-20 mA positioner and 4-20 mA output signal transmitter Supply voltages Extra (auxiliary) limit switches Parts List (Sizes 1/2" – 4") PARTS NO. Electric Actuator Manual Override Actuator Valve Stem Stainless Steel Actuator Standoffs Stainless Steel Position Indicator Stainless Steel EPDM, FKM, PTFE Encapsulated FKM Bellows Seal O-Ring Bellows Housing Body O-Ring Seat O-Ring Valve Seat PVC, PP, PVDF, PTFE EPDM, FKM, PTFE Encapsulated FKM PTFE EPDM, FKM, PTFE Encapsulated FKM PVC, PP, PVDF, PTFE Valve Plug Valve Body Sample Specification All thermoplastic modulating control valves shall be of the globe valve design. Valves shall have interchangeable seat and plugs to accommodate various flow coefficients (Cv) and flow characteristics shall be either linear or equal percentage. Stem seal shall be PTFE and of the bellows design. Electric actuator shall be constructed of glass-filled polyester (PEG) with stainless steel trim. Actuator shall operate with 120 VAC/1ph supply voltage, have a visual position indicator and be capable of on/ off or modulating operation. PVC shall conform to ASTM D1784 Cell Classification 12454-A, PP conforming to ASTM D4101 Cell Classification PP0210B67272, and PVDF conforming to ASTM D3222 Cell Classification Type II, and PTFE shall conform to PTFE TFE 1600, as manufactured by Asahi/America, Inc. ASAHI/AMERICA RECOMMENDS THE USE OF AV GASKETS FOR THIS PRODUCT LINE • Never remove valve from pipeline under pressure. • Always wear protective gloves and goggles.

Open the catalog to page 1
Electric Globe Control Valves - 2

Globe Control Valves Dimensions (in.) NOMINAL SIZE PVDF, PTFE Operating Pressure vs. Temperature (psi, water, non-shock) Troubleshooting PVDF/PTFE What if fluid flows even when fully closed? 1. lug or seat is damaged. P 2. Foreign matter caught or formed at What if it does not open? 3. Blown fuse in supply voltage line. What if fluid leaks from body? 1. Bolts for bellows housing are not tight. 2. O-ring(s) chemically attacked.

Open the catalog to page 2

All Asahi/America catalogs and technical brochures

  1. PDCPD

    2 Pages

  2. Pool-Pro

    2 Pages

  3. 92 series

    1 Pages

  4. 64 series

    1 Pages

  5. PA series

    2 Pages

  6. 56D/75D

    1 Pages

  7. 10 series

    2 Pages

  8. 94 series

    2 Pages

  9. 92 series

    2 Pages

  10. 87 series

    1 Pages