Catalog excerpts

Specifications Size: E87,F87 Torque: 5000-10,000 in/lbs Voltage: 120 VAC 1 Ph 50/60Hz AMP Draw: E87 1,7 F87 2.2 Conduit Entry: Two (2) 3.4" FNPT Max Ambient Temp: 150º F Switches: Four (4) single pole, double throw (4-SPDT) 15 amp rated Cycle Time per 90º: E87, F87 30 seconds Series 87 Electric Actuator Standard Features • Motor: Reversing, brushless, capacitor run 115 VAC • • • • • 50/60 Hz, single phase Overload protection: Integral thermal overload protection for motor windings with automatic reset Gear train: Permanently lubricated Conduit: Two 3/4” FNPT conduit entries to eliminate cross feed between control and power signals Manual override: Push down on handwheel until engaged with cam and rotate Limit switches: Standard end of travel limit switches can be used for light indication (not to be use with PLC for position confirmation) Auxiliary (Additional) limit switches: Each electric actuator is provided as a standard with 2-SPDT auxiliary limit switches Enclosure: Type 4X Mechanical Brake: Each electric actuator is provided as a standard with a mechanical brake Corrosion resistant mounting: Mounting is with stainless steel bracket, stainless steel coupling, and stainless steel hardware Output torque: Series 87 Electric Actuators have an output torque range from 5000 in/lbs to 10,000 in/lbs PTC Space Heater: A PTC (Positive Temperature Coefficient) space heater is provided as standard equipment Options • Two-wire control • Center-off • Voltages 10.0 CLEARANCE FOR COVER REMOVAL Sample Specification All Series 87 electric actuators shall have a thermally protected, bi-directional (reversing type), capacitor run motor with a permanently lubricated gear train. Actuator shall have planetary gearing encompassed in an die-cast aluminum housing with stainless steel trim, conforming to Type 4X. Each actuator shall have a manual override, visual position indication, two (2) auxiliary limit switches, a PTC heater and a mechanical brake as supplied by Asahi/America. Engineering Data ENGINEERING DATA Cycle Time per Weight Model 90 (lbs) Torque Amp Duty Amp Duty Degrees (in/lbs) Draw Cycle Draw Cycle (seconds) E87 5,000 1.7 50% 1.0 50% 30 34 F87 10,000 2.2 50% 1.2 50% 30 34 115 Vac • Local Remote Station
Open the catalog to page 1All Asahi/America catalogs and technical brochures
-
PDCPD
2 Pages
-
Halar Ball Valve
2 Pages
-
Pool-Pro
2 Pages
-
Datasheet_Globe_Valves
2 Pages
-
Datasheet_AV_Gaskets
1 Pages
-
Type-57P Butterfly Valve
5 Pages
-
High Purity Piping Systems
20 Pages
-
Pro-Vent ® Duct System
4 Pages
-
Welding Equipment
24 Pages
-
AS-I Bus Control System
2 Pages
-
92 series
1 Pages
-
64 series
1 Pages
-
PA series
2 Pages
-
56D/75D
1 Pages
-
Dymatrix Falconics
2 Pages
-
Dymatrix MPV Valves
6 Pages
-
Leak Detection Brochure
9 Pages
-
Fluid-Lok Brochure
4 Pages
-
Chem Prolok Catalog
12 Pages
-
Polytetra Heat Exchangers
8 Pages
-
Frank_Regulators
20 Pages
-
Goose Neck Faucets Brochure
6 Pages
-
High Purity Piping Brochure
16 Pages
-
Series 94 Electric Actuator
2 Pages
-
Series 10 Electric Actuator
2 Pages
-
P Series Limit Switch
1 Pages
-
Westlock Limit Switchbox
1 Pages
-
P Series Solenoid
1 Pages
-
Series 79 Pneumatic Actuator
12 Pages
-
Series 79 with Solenoid
1 Pages
-
Inductive Limit Switch
1 Pages
-
AS-i Bus Actuation
3 Pages
-
EM Technik Catalog
614 Pages
-
Wet Process Catalog
36 Pages
-
ProVent Catalog
16 Pages
-
Complete Valve Catalog
203 Pages
-
10 series
2 Pages
-
94 series
2 Pages
-
92 series
2 Pages
-
Actuation & Controls
60 Pages
-
Welding Equipment Catalog
20 Pages
-
Asahi Valve Catalog - Full 2011
136 Pages
-
Chem Proline Catalog
8 Pages
-
Air-Pro Catalog
20 Pages
-
Asahi-America General Catalog
12 Pages
-
Dymatrix Specialty Valve Catalog
74 Pages
-
Duo-Pro & Poly-Flo
4 Pages
-
Double Containment Brochure
8 Pages
-
Asahi Actuation Catalog
50 Pages