1. Catalogs
  2. ARTS Energy
  3. ecolife™ MH Cs
video corpo

ecolife™ MH Cs

ecolife™ MH Cs

ecolife™ MH Cs

Product catalog summary
Overview: ARTS Energy's ecolifeTM MH high temperature Ni-MH series is designed for emergency lighting and power backup, offering a 10-year design life in environments up to 40°C. The series supports intermittent charging across a temperature range of 0°C to 40°C, reducing energy consumption in luminaires.
Applications:
  • Emergency lighting (ELU)
  • Backup systems
Main Benefits:
  • 10-year lifespan at 40°C
  • Excellent charge efficiency at high temperatures
  • Intermittent charge capability
Technology:
  • Foam positive electrode
  • Plastic bonded metal-hydride negative electrode
Electrical Characteristics:
  • Nominal voltage: 1.2V
  • Typical capacity: 1700 mAh
  • IEC minimum capacity: 1600 mAh
  • Impedance at 1000 Hz: 6 mΩ
Dimensions:
  • Diameter: 22.0 ± 0.05 mm
  • Height: 42.7 ± 0.2 mm
  • Weight: 46 g
Charge Conditions:
  • Standard: 16 hours at 160 mA, 0 to +40°C
  • Intermittent: Consult ARTS Energy
Discharge Conditions:
  • Max Continuous: 4.8 A, 0 to +40°C
Storage Recommendations:
  • Temperature: +5°C to +25°C
  • Relative humidity: 65 ± 5%
Additional Notes: The battery must be operated according to ARTS Energy's technical recommendations to achieve stated performance. Data is subject to change and becomes contractual only after written confirmation by ARTS Energy.
See more

Catalog excerpts

ecolife™ MH Cs-1

ARTS ARTS Energy’s ecolifeTM MH high temperature Ni-MH series are perfectly suited to emergency lighting and power back-up requirements. With an intermittent charging regime, the design life is 10 years in high temperature environments (up + 40°C). The ecolifeTM MH Cs cell is designed to accept intermittent charge in a wide range of temperatures (0°C to + 40°C). The ecolifeTM MH Cs allows a significant reduction in the energy consumption of luminaires. To meet customers’ requirements, ARTS Energy provides custom-designed and standardised battery packs. For your battery design and system needs, please contact ARTS Energy’s engineers. Electrical characteristics • Back-up systems Main BENEFITs • 10 years life duration at 40°C • xcellent charge efficiency at high E • Intermittent charge Top flat area diameter (mm) Dimensions are given for bare cells. Charge conditions Rate • Foam positive electrode • lastic bonded metal-hydride negative P electrode Standard Intermittent discharge cONDITIONS Max Continuous Consult ARTS Energy CYCLING cONDITIONS ELU applications Back up applications High Temperature Series

 Open the catalog to page 1
ecolife™ MH Cs-2

High Temperature Series Storage For graphs shown, C is the IEC5 capacity. Charge 24h at C/20 at different temperatures 1.8 Recommended: + 5°C to + 25°C Relative humidity: 65 ± 5 % Voltage (V) Typical DIMENSIONs Cold temperature clamp at 1,55 V Discharge at 0.6 C at different temperatures after charge 24h at C/20 at different temperatures Typical dimensions (mm). Without tube. Discharge at C/4 at different temperatures after charge 24h at C/20 at different temperatures 1.6 The operation of the battery must strictly be in accordance with ARTS Energy technical recommendations, to obtain the Accelerated...