SUPPY UNIT and SUPPLY CONVERTER ST225 - 1 Pages

Add to MyDirectIndustry favorites
SUPPY UNIT and SUPPLY CONVERTER ST225

Catalog excerpts

SUPPY UNIT and SUPPLY CONVERTER ST225 Converter to adapt various standard signals Supply voltage for two-wire transmitter Plastic housing for mounting on 35 mm standard mounting rail according to EN50022 For conversion of standard signals. Incorporated supply voltage for supply of a two-wire measuring transmitter. Output signals are both a voltage 0...10 V and a current signal 0/4...20 mA. Both output signals are related to their common negative pole. ACCURACY / ERROR LIMIT: Tolerance: ± 0,2 % Temperature drift: ± 0,2 % / 10 K Operating Mode: Entrance: Supply voltage: Settings: TECHNICAL SPECIFICATIONS: Measurement mode 0 / 0.2 ... 1V, 0/2 ... 10V, 0/4 ... 20mA Approx. 18 Vdc, unstabilized, max. 25 mA Measuring range adjustable via trimmer PHYSICAL: Display: Operating indicator green, overdrive or sensor break red Casing: Polyamide gray, for mounting on a 35 mm standard profile rail according to EN 50022 Dimensions: 22.5 x 99 x 110 mm (W x H x D) Protection class: IP 20 according to EN 60529 Connections: Screw terminals up to 2.5 mm² Ambient temperature: -10 to 50 ° C Rel. humidity: 0 ... 85%, no condensation Weight: Approx. 160 g ELECTRONIC: Power supply: 230 Vac / 115 Vac via input. Transformer or 24 Vac or 24 Vdc Power consumption: Approx. 1.5 VA Test sockets: 2 mm ø for measuring the output current, internal resistance of the current meter max. 10 Ω Voltage output: 0 ... 10 V, short circuit proof, max. 5 mA Current output: 0/4 ... 20 mA, max. Load 600 Ω Max. Output current: Approx. 25 mA for overdrive or sensor break, indicated by red LED CONFORMITY: EMC: EN 61000-6-2, EN 61000-6-3, CE-mark RoHS: according RoHS-directive 2011/65/EU Item no. Supply unit and supply converter ST225 Input: Customer-specific presetting required! Supply voltage: approx. 18 Vdc, non-stabilized Output: 0...10 V and 0/4...20 mA Supply voltage: 230/115 Vac, 24 Vac or 24 Vdc Arthur Grillo GmbH • Am Sandbach 7 • 40878 Ratingen • phone 0 21 02 - 47 10 22 • fax 0 21 02 - 47 58 82 www.grillo-messgeraete.de/en • Email: info@grillo-messgeraete.de • web shop: www.se

 Open the catalog to page 1

All Arthur Grillo GmbH catalogs and technical brochures

  1. data sheet mkm

    1 Pages

  2. data sheet AF1

    1 Pages

  3. data sheet O2T

    1 Pages

  4. data sheet ETF

    1 Pages

  5. data sheet edr

    1 Pages

  6. data sheet wbv

    1 Pages

  7. data sheet mbz

    1 Pages

  8. data sheet CM2

    1 Pages

  9. data sheet MID

    1 Pages

  10. SPECIAL

    18 Pages

  11. TEMPERATURE

    20 Pages

  12. Display

    14 Pages

  13. HUMIDITY

    21 Pages

  14. PRESSURE

    35 Pages

  15. data sheet

    2 Pages

  16. data sheet DS85

    2 Pages

  17. data sheet DA85

    1 Pages

  18. data sheet

    2 Pages

  19. data sheet DS85

    2 Pages

  20. SHT11/15

    1 Pages

  21. Orifice plate

    3 Pages

  22. SGI

    1 Pages

  23. Venturirohr

    4 Pages

  24. MR 90

    4 Pages

Archived catalogs

  1. MID

    1 Pages

  2. MINI90

    1 Pages

  3. RGF

    1 Pages

  4. WBV

    1 Pages

  5. DS85-P

    2 Pages

  6. DS85

    1 Pages

  7. DPCS200

    2 Pages

  8. WR 90

    1 Pages

  9. AQD / AQ72

    1 Pages

  10. TOUCHSCREEN

    1 Pages

  11. AD-72P

    1 Pages

  12. AD96TF

    1 Pages

  13. AD 72P-ST

    1 Pages

  14. AD 72P-WT

    1 Pages

  15. AD 96TF

    1 Pages

  16. AFD

    1 Pages

  17. AFD-TK

    1 Pages

  18. CM2

    1 Pages

  19. O2T

    1 Pages

  20. ST225

    1 Pages

  21. SP225

    1 Pages

  22. TR225

    1 Pages

  23. GS225

    1 Pages

  24. GIV

    1 Pages

  25. Flora II

    1 Pages

  26. AF 1

    1 Pages

  27. catalogue

    80 Pages